Atomic Absorption Spectrophotometer LAAS-A22

Atomic Absorption Spectrophotometer LAAS-A22

Atomic Absorption spectrophotometer comes with flame, graphite furnace and hydride generation system to meet different customer demand. It is provided with deuterium hollow cathode lamp to eliminate the interference of molecular absorption and Titanium Burner to improve the analysis efficiency and accuracy of the flame. The autosampler has integrated graphite furnace design with high-precision syringes to enter volume as minimum as 0.5μl with intelligent online dilution and concentration function. It has great applications research and medicine, environmental science and other industries.

Request Quote
Wavelength range 180 – 900 nm
Spectral Bandwidth 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs/30 min (Static) ≤ ± 0.005 Abs/30 min (Dynamic)
Sample Volume 1 - 100 μl
The volume of sample better than 1 %(at the time of 10 mL - 100 mL)
Repeated Sampling Frequency up to 99 Times
Cleaning and waste container volume Each 500 mL
Absorbance Range 0 - 4 A
The Program Automatic temperature control up to 20 order
Temperature Range room temperature to 3000 ℃
Detector imported photomultiplier tube
Heating Mode vertical heating
Temperature Control Method Vertical optical temperature monitoring graphite tube wall temperature
Temperature Control The furnace enriched up to 20 times
Lamp holder ≤ 6 lamps automatic turret, automatic alignment
Lamp power supply mode pulsed power supply
Optical System Large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristics Volume 0.5 × 10-12g (Cd)
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit 0.4 × 10-12g (Cd)
Detection Limit (Cu) 0.002 μg/mL
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5
Ignition Type Microcomputer control, automatic ignition
Sample Tray 70 sample cups, 6 reagent cup
The Smallest Lincrement 0.1 μl
Safety measures The graphite tube damage, water flow Air pressure and other alarm temperature overheating protection
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The Cooling Water Can choose cooling water circulation system
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Power supply 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA
  • High precision automatic optical system
  • Graphite furnace temperature control
  • High technical indicators
  • Deuterium lamp for background correction system
  • Polymer automization chamber
  • Powerful, intelligent user-friendly design
  • Automatic analysis & Sampler

Atomic Absorption spectrophotometer is used in scientific research, quality control, disease control, environmental protection, metallurgy, agriculture, chemical industry, and analysis of samples, equipment maintenance, simple and convenient.

Similar Products


Atomic Absorption Spectrophotometer LAAS-A22 FAQ's
  • Our LAAS-A22’s deuterium light is specifically included in the system for background correction, which ensures reliable analytical findings by removing molecular absorption interference.

  • Our LAAS-A22 operates at a frequency of 60/50 Hz and needs a power source of 110/220 V with a tolerance of +5% to -10%. The product requires 5000 VA of electricity.

  • Our atomic absorption spectrophotometer LAAS-A22 offers greater versatility and precision in spectral analysis with its automated spectrum bandwidth of 0.1, 0.2, 0.4,1.0, and 2.0 nm.

  • An analytical tool called an Atomic Absorption Spectrophotometer (AAS) uses the light that each element's atom absorbs to determine the concentration of that element in a sample.

  • The basis of spectrophotometry is the light uptake by unbound atoms in a gaseous state. An excited state is created when atoms in the ground state absorb light energy at particular wavelengths. Analyte content in the sample can be calculated by determining the amount of light consumed.

  • The components include an atomizer (commonly used atomizers are Flame atomizers and Electro thermal atomizers), a Radiation source, and a spectrophotometer.

  • The hollow cathode lamp in atomic absorption spectrophotometer emits distinctive light at particular wavelengths that match the target analyte. This guarantees that the analyte atoms are excited selectively, resulting in exact and reliable readings.

  • Labtron’s Atomic Absorption Spectrophotometers boast flexible atomization technologies, accurate optical systems, a titanium combustion head, and a polymer explosion-proof spray chamber. These elements guarantee accurate and effective trace element analysis, along with improved safety and longevity.

Post your question?

Our experts are here to help!

Atomic Absorption Spectrophotometer : Labtron Atomic Absorption Spectrophotometers offer precise and efficient trace element analysis with adaptable atomization technologies and high-precision optical systems. These feature a titanium combustion head, polymer explosion-proof spray chamber with enhanced safety features and durability. We offer versatile operation modes, including flame, graphite furnace, and hydride generation systems, these meet diverse analytical needs. Our Spectrophotometers boast powerful software and user-friendly design for consistent, reliable results and seamless data management.
Atomic Absorption Spectrophotometer LAAS-A23, Atomic Absorption Spectrophotometer LAAS-A20, Atomic Absorption Spectrophotometer LAAS-A21, Atomic Absorption Spectrophotometer LAAS-A11, Atomic Absorption Spectrophotometer LAAS-A13, Flame Atomic Absorption Spectrophotometer LAAS-A12, Atomic Absorption Spectrophotometer LAAS-A14, Atomic Absorption Spectrophotometer LAAS-A24, Atomic Absorption Spectrophotometer LAAS-A25, Flame Atomic Absorption Spectrophotometer LAAS-A15, and more.

Quick Links : About Us, Contact Us, User Manuals, Career, Terms of Use, Policies, Sitemap, Gallery.

Need a Product

send details for best price quotation

Click
For

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2024 Labtron Equipment Ltd. All rights reserved.