Request A Quote
Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer LAAS-A11

Atomic Absorption Spectrophotometer LAAS-A11 operates at wavelengths between 190 and 900 nm. It is a dual-beam source system that assists in identifying trace elements. Equipped with deuterium lamp that enhances accuracy by reducing background scatter. No cathode lamp pre-heating speeds up sample analysis. Enables quick sample analysis, crucial for high-volume testing. Its High-energy optical path boosts sensitivity and accuracy in measurements. Our spectrophotometer compensates for circuit drift, ensuring stable results.

Atomic Absorption Spectrophotometer LAAS-A11
Atomic Absorption Spectrophotometer LAAS-A11
Request Quote
Wavelength Range 190 to 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength Accuracy ≤ ± 0.5 nm
Wavelength Repeatability ≤ 0.3 nm (single direction)
Baseline Drift ± 0.004 Abs / 30 min
Resolution < 40 %
Characteristic Concentration (Cu) ≤ 0.04 mg / ml / 1 %
Detection Limit (Cu) 0.008 mg/ml
Background Calibration Ability Greater than 30 times
Power 220 V / 3 A, 50 Hz
Dimension 1220 × 770 × 730 mm
Weight 160 Kg
  • Integrated computer and LCD display
  • Multiple analysis options
  • Safe and leak-proof gas system
  • RS232 interface for easy data transfer

Atomic Absorption Spectrophotometer is utilized across various sectors including environmental analysis, geology, metallurgy, petrochemical industries, food and beverages, medicines, ceramics, paints, and chemical industries for precise quantification of specific elements.

A graphite furnace system Titanium burner (5cm) Nitrous oxide generator Hydride generator Graphite tubes Acetylene regulator Nitrous oxide regulator Software Recirculating cooling water system

Models of Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometers offer precise and efficient trace element analysis with adaptable atomization technologies and high-precision optical systems. These feature a titanium combustion head, polymer explosion-proof spray chamber with enhanced safety features and durability. We offer versatile operation modes, including flame, graphite furnace, and hydride generation systems, these meet diverse analytical needs. Our Spectrophotometers boast powerful software and user-friendly design for consistent, reliable results and seamless data management.

Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption Spectrophotometer LAAS-A21

  • Wavelength range : 180 – 900 nm
  • Spectral Bandwidth : 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm(5 steps with automatic changeover)
  • Wavelength accuracy : ≤ 0.15 nm
  • Wavelength repeatability : ± 0.1 nm
Atomic Absorption Spectrophotometer LAAS-A24

Atomic Absorption Spectrophotometer LAAS-A24

  • Wavelength Range : 190nm to 900nm
  • Light Source : 8-Lamp Turret 2 Positions for High-Performance Lamp
  • Lamp Current Range : 0 To 15ma
  • Optical System Filter : Czemy-Turner Monochromator
Atomic Absorption Spectrophotometer LAAS-A26

Atomic Absorption Spectrophotometer LAAS-A26

  • Wavelength Range : 190 to 900nm
  • Spectral Bandwidth : 0.1, 0.2, 0.4, 1.0, 2.0nm (automatic adjustable)
  • Wavelength Accuracy : ±0.15nm
  • Wavelength Repeatability : ±0.1nm
Flame Atomic Absorption Spectrophotometer LAAS-A12
Flame Atomic Absorption Spectrophotometer LAAS-A12
  • Optical System : Single-beam design
  • Wavelength Range : 190 to 900 nm
  • Spectral Bandwidth : Automated selection (0.1, 0.2, 0.4, 0.7, 1.4 nm)
  • Light Source : Automated 8-lamp turret with independent pre-heat
Atomic Absorption Spectrophotometer LAAS-A23
Atomic Absorption Spectrophotometer LAAS-A23
  • Wavelength range : 185 to 900 nm
  • Spectral Bandwidth : 0.1 nm,0.2 nm,0.4 nm, 0.7 nm, 1.0 nm, 1.4 nm, 2.0 nm automatic setting
  • Wavelength accuracy : ± 0.15 nm
  • Wavelength repeatability : < 0.1 nm
Atomic Absorption Spectrophotometer LAAS-A25

Atomic Absorption Spectrophotometer LAAS-A25

  • Wavelength Range : 190 to 900 nm
  • Spectral Bandwidth : 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
  • Wavelength Accuracy : ≤ ± 0.5 nm
  • Wavelength Repeatability : ≤ 0.3 nm (single direction)
Atomic Absorption Spectrophotometer LAAS-A22

Atomic Absorption Spectrophotometer LAAS-A22

  • Wavelength range : 180 – 900 nm
  • Spectral Bandwidth : 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
  • Wavelength accuracy : ≤ 0.15 nm
  • Wavelength repeatability : ± 0.1 nm
Atomic Absorption Spectrophotometer LAAS-A20

Atomic Absorption Spectrophotometer LAAS-A20

  • Wavelength Range : 190 to 900 nm
  • Spectral Bandwidth : 0.1, 0.2, 0.4, 1.0, 2.0 nm (automatically adjustable)
  • Wavelength Accuracy : ±0.15 nm
  • Wavelength Repeatability : ±0.1 nm

Atomic Absorption Spectrophotometer LAAS-A11 FAQ's
  • Our product LAAS-A11 accelerates the sample analysis process by eliminating the need for cathode lamp pre-heating. This attribute serves as vital for high-volume testing since it enables quick and effective examination of an enormous number of samples.

  • By compensating for circuit drift, Labtron’s LAAS-A11 produces consistent outcomes over time. This function compensates automatically for variations in the circuitry of the device, preserving measurement precision and dependability.

  • A titanium burner (5 cm), a graphite furnace system, a nitrous oxide generator, a hydride generator, graphite tubes, an acetylene regulator, a nitrous oxide regulator, software, and a recirculating cooling water system are among the optional accessories for our LAAS-A11. For certain analysis requirements, these accessories enable greater flexibility and versatility.

  • An analytical tool called an Atomic Absorption Spectrophotometer (AAS) uses the light that each element's atom absorbs to determine the concentration of that element in a sample.

  • The basis of spectrophotometry is the light uptake by unbound atoms in a gaseous state. An excited state is created when atoms in the ground state absorb light energy at particular wavelengths. Analyte content in the sample can be calculated by determining the amount of light consumed.

  • The components include an atomizer (commonly used atomizers are Flame atomizers and Electro thermal atomizers), a Radiation source, and a spectrophotometer.

  • The hollow cathode lamp in atomic absorption spectrophotometer emits distinctive light at particular wavelengths that match the target analyte. This guarantees that the analyte atoms are excited selectively, resulting in exact and reliable readings.

  • Labtron’s Atomic Absorption Spectrophotometers boast flexible atomization technologies, accurate optical systems, a titanium combustion head, and a polymer explosion-proof spray chamber. These elements guarantee accurate and effective trace element analysis, along with improved safety and longevity.

Post your question?

Our experts are here to help!

Atomic Absorption Spectrophotometer:
Atomic Absorption Spectrophotometer LAAS-A21, Atomic Absorption Spectrophotometer LAAS-A24, Atomic Absorption Spectrophotometer LAAS-A26, Flame Atomic Absorption Spectrophotometer LAAS-A12, Atomic Absorption Spectrophotometer LAAS-A23, Atomic Absorption Spectrophotometer LAAS-A25, Atomic Absorption Spectrophotometer LAAS-A22, Atomic Absorption Spectrophotometer LAAS-A20, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.