Request A Quote
Automatic PMCC Flash Point Tester LCFP-A13

Automatic PMCC Flash Point Tester LCFP-A13

Automatic PMCC Flash Point Tester LCFP-A13 can determine the flash point and ignition point in the measuring range of 40 ℃ to 350 ℃. Enhanced with a power failure memory function. It can store up to 1000 analysis results. This tester is designed to meet the requirements of D93 GB/T, 261-2008 ASTM standard methods. Capable of locking the cooling function automatically. Our tester Offers accurate measurement, excellent repeatability, and consistently stable and reliable performance.

Request Quote
Ambient Temperature 10 ℃ to 35 ℃
Relative Humidity < 85%
Ignition Mode Electric Ignition
Cooling Method Forced Air Cooling
Temperature Range RT to 350 ℃
Temperature Test Platinum Resistance
Storage 1000 analysis results
Measurement Range 40 ℃ to 350 ℃
Display color LCD
Operation Mode touchscreen
Printer Thermal Printer
Repeatability 110℃ ±2℃ (>110℃)
110℃±1℃ (<110℃)
Standards D93 GB/T ASTM 261
Battery Button Battery
Power Consumption Magnetic DC 30W
Power Supply 350VA 220V + 50Hz, 11V + 2.5HZ
Dimension 500 × 400 × 380 mm
Weight 20Kg
  • Utilizes ARM microprocessor technology
  • Features a color LCD touchscreen
  • Provided with thermal printer
  • Performs automatic ignition
  • Displays and print results
  • Straightforward and user-friendly operation

Automatic PMCC Flash Point Tester is used for the determination of closed cup flash point value and ignition point of petroleum products. It finds extensive applications in sectors such as electric power, petroleum, chemical industry, commodity inspection, and research.

Accessories Qty
Test Cup 1 pc
Lid with Shutter Mechanism 1 pc
Ignition Wire 1 pc
Stirrer Assembly 1 pc
Temperature Probe 1 pc
Safety Cover 1 pc
Calibration Standard Oil Sample 150ml,1 pc
Power Adapter 1 pc
Software Interface Cable 1 pc

Models of Closed Cup Flash Point Tester

Labtron Closed Cup Flash Point Tester is specialized to determine lowest temperature at which vapor above liquid can ignite when exposed to open flame or spark. They are equipped with thermometers to ensure readings upto 300℃ during testing. Their sample containers are made from heat-resistant materials to withstand high thermal condition. They include built-in ventilation system that manage fumes generated during process. Our Closed Cup Flash Point Tester to assess flammability risk of fluids in petrochemicals, paints, and solvents.

Digital Closed Cup Flash Point Tester LCFP-B10

Digital Closed Cup Flash Point Tester LCFP-B10

  • Thermometer Type : Internal marked mercury thermometer; complies to GB514 standard.
  • Oil Test Capacity : about 70ml
  • Depth of oil Test Capacity Marking Line : 34.2mm
  • Oil Cup Inner Diameter : 50.8mm
PMCC Flash Point Tester LCFP-A15

PMCC Flash Point Tester LCFP-A15

  • Measuring Range : 40 to 370℃ (104 to 698℉)
  • Resolution : 0.1℃
  • Heater Rate : Procedure A: 5℃/min to 6℃/minProcedure B: 1.0℃/min to 1.5℃/minProcedure C: 2.5℃/min to 3.5℃/min
  • Stirring Speed : Procedure A: 90r/min to 120r/minProcedure B: 250r/min ± 10r/minProcedure C: 90r/min to 120r/min
Automatic PMCC Flash Point Tester LCFP-A14

Automatic PMCC Flash Point Tester LCFP-A14

  • Temperature Range : 0 ℃ to 60 ℃
  • Temperature Accuracy : ±0.5℃
  • Ambient Temperature : 15℃ to 35℃
  • Relative Humidity : ≤ 85%
Automatic PMCC Flash Point Tester LCFP-A12
Automatic PMCC Flash Point Tester LCFP-A12
  • Flash Point Determination Range : Ambient to 230℃
  • Accuracy : 0.1℃
  • Heating Rate : Procedure A: (5 to 6)℃/min
  • Stirring Rate : Procedure A and C: 90 to 120 rpm
Automatic PMCC Flash Point Tester LCFP-A11
Automatic PMCC Flash Point Tester LCFP-A11
  • Ambient Temperature : ≤ 40℃
  • Relative Humidity : ≤ 80 %
  • Measurement Range : Ambient to 300℃
  • Flash Point : Lower than 104℃, error is 2℃; Higher than 104℃, error is 6℃
Manual PMCC Flash Point Tester LCFP-A10

Manual PMCC Flash Point Tester LCFP-A10

  • Temperature Range : RT to 370℃
  • Temperature Resolution : 1℃
  • Thermometer Type : Mercury-in-glass thermometer
  • Test Oil Capacity : 70 mL

Closed Cup Flash Point Tester:
Digital Closed Cup Flash Point Tester LCFP-B10, PMCC Flash Point Tester LCFP-A15, Automatic PMCC Flash Point Tester LCFP-A14, Automatic PMCC Flash Point Tester LCFP-A12, Automatic PMCC Flash Point Tester LCFP-A11, Manual PMCC Flash Point Tester LCFP-A10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.