Request A Quote
Digital Closed Cup Flash Point Tester LCFP-B10

Digital Closed Cup Flash Point Tester LCFP-B10

Digital Closed Cup Flash Point Tester LCFP-B10 features standardized closed cup of 50.8mm diameter. Ensures safety and reliability with high-precision air valve adjustment system. Equipped with separate buttons for temperature rise and air cooking control functions. Features automatic or electric ignition system with flame detection and safety shutoff. Ideally used to determine the flash point of diesel, kerosene, paints, resins and gels.

Request Quote
Thermometer Type Internal marked mercury thermometer; complies to GB514 standard.
Oil Test Capacity about 70ml
Depth of oil Test Capacity Marking Line 34.2mm
Oil Cup Inner Diameter 50.8mm
Oil Cup Depth 56mm
Igniting Device Gas ignition
Ignition Mode Automatically electronic ignition with airs source
Ambient Temperature 10℃ to 45℃
Relative Humidity 30 to 80%
Hating Power Heating power 600W,
Power Consumption Less than or equal to 650W
Power Supply AC 220V±10%,50Hz
Dimension 397mm × 305mm × 240mm
Net Weight 15 kg
Gross Weight 18 kg
  • Auto Fault Detection
  • Real-time LED Voltage Display
  • Anti-Corrosive Cup
  • Continuously Adjustable Heating
  • High-Precision Temperature Control
  • Motorized Flexible Stirring

Our Digital Closed Cup Flash Point Tester LCFP-B10 is ideally used in petroleum, chemical, pharmaceutical, food, solvent and other industries, to determine the flash point of diesel, kerosene, paints, resins, cremes and gels.

Models of Closed Cup Flash Point Tester

Labtron Closed Cup Flash Point Tester is specialized to determine lowest temperature at which vapor above liquid can ignite when exposed to open flame or spark. They are equipped with thermometers to ensure readings upto 300℃ during testing. Their sample containers are made from heat-resistant materials to withstand high thermal condition. They include built-in ventilation system that manage fumes generated during process. Our Closed Cup Flash Point Tester to assess flammability risk of fluids in petrochemicals, paints, and solvents.

Automatic PMCC Flash Point Tester LCFP-A12

Automatic PMCC Flash Point Tester LCFP-A12

  • Flash Point Determination Range : Ambient to 230℃
  • Accuracy : 0.1℃
  • Heating Rate : Procedure A: (5 to 6)℃/min
  • Stirring Rate : Procedure A and C: 90 to 120 rpm
PMCC Flash Point Tester LCFP-A15

PMCC Flash Point Tester LCFP-A15

  • Measuring Range : 40 to 370℃ (104 to 698℉)
  • Resolution : 0.1℃
  • Heater Rate : Procedure A: 5℃/min to 6℃/minProcedure B: 1.0℃/min to 1.5℃/minProcedure C: 2.5℃/min to 3.5℃/min
  • Stirring Speed : Procedure A: 90r/min to 120r/minProcedure B: 250r/min ± 10r/minProcedure C: 90r/min to 120r/min
Automatic PMCC Flash Point Tester LCFP-A11

Automatic PMCC Flash Point Tester LCFP-A11

  • Ambient Temperature : ≤ 40℃
  • Relative Humidity : ≤ 80 %
  • Measurement Range : Ambient to 300℃
  • Flash Point : Lower than 104℃, error is 2℃; Higher than 104℃, error is 6℃
Manual PMCC Flash Point Tester LCFP-A10
Manual PMCC Flash Point Tester LCFP-A10
  • Temperature Range : RT to 370℃
  • Temperature Resolution : 1℃
  • Thermometer Type : Mercury-in-glass thermometer
  • Test Oil Capacity : 70 mL
Automatic PMCC Flash Point Tester LCFP-A13
Automatic PMCC Flash Point Tester LCFP-A13
  • Ambient Temperature : 10 ℃ to 35 ℃
  • Relative Humidity : < 85%
  • Ignition Mode : Electric Ignition
  • Cooling Method : Forced Air Cooling
Automatic PMCC Flash Point Tester LCFP-A14

Automatic PMCC Flash Point Tester LCFP-A14

  • Temperature Range : 0 ℃ to 60 ℃
  • Temperature Accuracy : ±0.5℃
  • Ambient Temperature : 15℃ to 35℃
  • Relative Humidity : ≤ 85%

Digital Closed Cup Flash Point Tester LCFP-B10 FAQ's
  • Labtron’s Digital Closed Cup Flash Point Tester LCFP-B10 is designed to accurately determine the flash point of flammable liquids, including diesel, kerosene, paints, resins, and gels. Flash point determination is critical for classifying substances based on flammability and ensuring safe handling and storage. The closed cup design simulates real-world containment and is ideal for volatile samples. It is widely used in petroleum, chemical, food, and pharmaceutical industries for product evaluation and quality control.

  • Labtron’s Digital Closed Cup Flash Point Tester LCFP-B10 is equipped with a high-precision air valve adjustment system that allows accurate regulation of air supply for consistent ignition. This helps maintain a stable testing environment and prevents unsafe combustion fluctuations. The valve system enhances operator safety by supporting controlled flame conditions and contributes to the accuracy of the flash point results. It is especially beneficial in environments with variable ambient conditions.

  • Labtron’s Digital Closed Cup Flash Point Tester LCFP-B10 features an automatic electronic ignition system powered by an external air source. It eliminates the need for manual flame introduction, reducing the risk of operator error or injury. The ignition system includes flame detection sensors and an automatic shutoff function to enhance operational safety. This fully automated ignition mechanism ensures consistency in repeated tests and increases user confidence in the results.

  • The standardized 50.8 mm closed oil cup ensures uniformity and compatibility with widely accepted testing protocols. It is made of anti-corrosive material to resist chemical damage and maintain longevity. Its depth of 56 mm and capacity of approximately 70 ml are ideal for replicable test setups. The closed cup method offers greater safety and accuracy by containing vapors and simulating real-world combustion risk scenarios under controlled conditions.

  • The Digital Closed Cup Flash Point Tester LCFP-B10 is suitable for a wide variety of flammable samples such as diesel, lubricants, kerosene, solvents, varnishes, resins, creams, gels, and other volatile liquids. It is commonly used in petroleum testing labs, chemical manufacturing plants, cosmetic and pharmaceutical industries, food flavor testing, and environmental compliance labs. The tester provides reliable data for both raw materials and finished products, ensuring safety and regulatory adherence.

  • The Digital Closed Cup Flash Point Tester LCFP-B10 includes user-friendly features such as separate buttons for temperature rise and air cooking control, allowing operators to manage the heating process more precisely. A real-time LED voltage display keeps users informed during the test process, while auto fault detection enhances diagnostic efficiency. Combined with high-precision temperature control and motorized flexible stirring, the unit offers an efficient, accurate, and hassle-free testing experience.

Post your question?

Our experts are here to help!

Closed Cup Flash Point Tester:
Automatic PMCC Flash Point Tester LCFP-A12, PMCC Flash Point Tester LCFP-A15, Automatic PMCC Flash Point Tester LCFP-A11, Manual PMCC Flash Point Tester LCFP-A10, Automatic PMCC Flash Point Tester LCFP-A13, Automatic PMCC Flash Point Tester LCFP-A14, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.