Request A Quote
Automatic PMCC Flash Point Tester LCFP-A14

Automatic PMCC Flash Point Tester LCFP-A14

Automatic PMCC Flash Point Tester LCFP-A14 conforms to GB/T6536 and ASTM D86 standards for petroleum product distillation testing. It is a double-unit tester with a condenser pipe reaching a minimum of 0℃. Our tester works in a temperature range of 0℃ to 60℃ with an accuracy of ±0.5℃. It incorporates a new type of refrigeration compressor. This tester is ideal for low-temperature distillation testing of petroleum products.

Request Quote
Temperature Range 0 ℃ to 60 ℃
Temperature Accuracy ±0.5℃
Ambient Temperature 15℃ to 35℃
Relative Humidity ≤ 85%
Cylinder Volume 100ml
Distillation Flask Volume 125ml (GB/T 6536 and ASTM D86)
Flask Support Board SiC
Board Diameter φ32mm, φ38mm, φ50mm.
Thermometer Temperature -2 to 300 ℃ and -2 to 400 ℃
Display LED
Total Power Consumption ≤ 5400W
Power Supply AC(220±10%)V, 50Hz
Dimension 730 × 530 ×5 80mm
Weight 59kg
  • Capable of simultaneously testing one or two samples
  • Achieve rapid cooling just within 50 minutes
  • Specially designed heating furnace for safety
  • Features adjustable heating power
  • Stainless steel refrigeration bath

Automatic PMCC Flash Point Tester is used for determining the distillation characteristics of various petroleum products such as gasoline, aviation gasoline, jet fuels, solvents with specific boiling points, naphtha, diesel oil, distillate fuels, and others.

Models of Closed Cup Flash Point Tester

Labtron Closed Cup Flash Point Tester is specialized to determine lowest temperature at which vapor above liquid can ignite when exposed to open flame or spark. They are equipped with thermometers to ensure readings upto 300℃ during testing. Their sample containers are made from heat-resistant materials to withstand high thermal condition. They include built-in ventilation system that manage fumes generated during process. Our Closed Cup Flash Point Tester to assess flammability risk of fluids in petrochemicals, paints, and solvents.

PMCC Flash Point Tester LCFP-A15

PMCC Flash Point Tester LCFP-A15

  • Measuring Range : 40 to 370℃ (104 to 698℉)
  • Resolution : 0.1℃
  • Heater Rate : Procedure A: 5℃/min to 6℃/minProcedure B: 1.0℃/min to 1.5℃/minProcedure C: 2.5℃/min to 3.5℃/min
  • Stirring Speed : Procedure A: 90r/min to 120r/minProcedure B: 250r/min ± 10r/minProcedure C: 90r/min to 120r/min
Automatic PMCC Flash Point Tester LCFP-A12

Automatic PMCC Flash Point Tester LCFP-A12

  • Flash Point Determination Range : Ambient to 230℃
  • Accuracy : 0.1℃
  • Heating Rate : Procedure A: (5 to 6)℃/min
  • Stirring Rate : Procedure A and C: 90 to 120 rpm
Manual PMCC Flash Point Tester LCFP-A10

Manual PMCC Flash Point Tester LCFP-A10

  • Temperature Range : RT to 370℃
  • Temperature Resolution : 1℃
  • Thermometer Type : Mercury-in-glass thermometer
  • Test Oil Capacity : 70 mL
Digital Closed Cup Flash Point Tester LCFP-B10
Digital Closed Cup Flash Point Tester LCFP-B10
  • Thermometer Type : Internal marked mercury thermometer; complies to GB514 standard.
  • Oil Test Capacity : about 70ml
  • Depth of oil Test Capacity Marking Line : 34.2mm
  • Oil Cup Inner Diameter : 50.8mm
Automatic PMCC Flash Point Tester LCFP-A13
Automatic PMCC Flash Point Tester LCFP-A13
  • Ambient Temperature : 10 ℃ to 35 ℃
  • Relative Humidity : < 85%
  • Ignition Mode : Electric Ignition
  • Cooling Method : Forced Air Cooling
Automatic PMCC Flash Point Tester LCFP-A11

Automatic PMCC Flash Point Tester LCFP-A11

  • Ambient Temperature : ≤ 40℃
  • Relative Humidity : ≤ 80 %
  • Measurement Range : Ambient to 300℃
  • Flash Point : Lower than 104℃, error is 2℃; Higher than 104℃, error is 6℃

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.