Double Beam UV-Vis Spectrophotometer LUS-B60 comes with a 0.5 to 5 nm variable bandwidth for flexible analysis. The 190 to 1100 nm wavelength range supports diverse spectral applications. A double-beam optical system with a 1200 line/mm holographic grating ensures reliable performance. Its graphic LCD delivers clear data visualization and intuitive operation. Ideal for quantitative analysis, dynamic testing, and various laboratory applications.

Double Beam UV-Vis Spectrophotometer LUS-B60
Double Beam UV-Vis Spectrophotometer LUS-B60
Request Quote
Optical System Double beam/Proportional monitoring (optional), CT type light path, 1200 line/mm Laser holographic diffraction grating
Wavelength Range 190 to 1100 nm
Spectral Bandwidth 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
Wavelength Accuracy ±0.1 nm (656.1 nm D2), ±0.3 nm
Wavelength Repeatability ±0.1 nm
Photometric Accuracy ±0.002 A @0.5 A, ±0.004 A @1 A
Photometric Display Range -0.3 to 3A, 0-200%T, -9999 to 9999C
Zero Setting Auto-tune 100%T and 0%T
Stray Light ≤0.03%T @220 nm, 340 nm
Stability ±0.0005 A/hr @500 nm
Baseline Flatness 0A
Working Mode T, A, C, E
Wavelength Setting Automatic
Minimum Resolution 0.1 nm
Interface Display 320×240 graphic LCD
Communication Interface USB port
Light Source Imported halogen tungsten lamp and deuterium lamp
Detector Imported Si Photodiode
Dimensions 660×580×270 mm
Weight 29 kg
  • Enhanced optical system performance

  • Wide measurement wavelength range

  • High-resolution scanning capability

  • Efficient noise reduction design

  • User-friendly operational controls

  • High stability with low stray light

Our Double Beam UV-Vis Spectrophotometer LUS-B60 is used in pharmaceutical testing, biochemical research, environmental analysis, and chemical laboratories for precise spectroscopic measurements.

AccessoryQuantity
Main unit1 pc
Glass cells (1 cm)4 pcs
Quartz cells (1 cm)2 pcs
Dust cover1 pc
Power cord1 pc

Download catalog for
Double Beam UV-Vis Spectrophotometer LUS-B60 Catalog

Available Range :

Double Beam UV/Vis Spectrophotometer LUS-B70 : Czerny-Turner (CT) design, double beam Double Beam UV-Visible Spectrophotometer LUS-B24 : Double Beam, Grating 1200 lines/ mm Double Beam UV-Vis Spectrophotometer LUS-B23 : Double beam Double Beam UV-Vis Spectrophotometer LUS-B32 : Double beam 1200 lines/mm Double Beam UV-VIS Spectrophotometer LUS-B41 : Double Beam 1200 nm grating Double Beam UV-Vis Spectrophotometer LUS-B40 : Double beam grating 1200 lines/mm Double Beam UV-Vis Spectrophotometer LUS-B20 : Double beam, C-T monochromator, 1600 L/mm holographic grating Double Beam UV-Vis Spectrophotometer LUS-B12 : Double beam, C-T monochromator,1200 L/mm holographic grating Double Beam UV-Vis Spectrophotometer LUS-B62 : Double beam, CT type light path, 1200 line/mm laser holographic diffraction grating Double Beam UV-Vis Spectrophotometer LUS-B33 : Double Beam, Grating 1200 lines/ mm Double Beam UV-Vis Spectrophotometer LUS-B30 : Double Beam, Grating 1200 lines/mm Double Beam UV-Vis Spectrophotometer LUS-B60 : Double beam/Proportional monitoring (optional), CT type light path, 1200 line/mm Laser holographic diffraction grating Double Beam UV-Vis Spectrophotometer LUS-B11 : Double beam; 1200 lines/mm grating Double Beam UV-Vis Spectrophotometer LUS-B42 : Optical double beam system Double Beam UV-Vis Spectrophotometer LUS-B51 : Proportional double beam path Double Beam UV-Vis Spectrophotometer LUS-B50 : Proportional double beam system Double Beam UV-Vis Spectrophotometer LUS-B63 : Quasi double beam ratio monitoring optical path, holographic diffraction grating

Models of Double Beam UV-Vis Spectrophotometer

Labtron UV-Vis double beam Spectrophotometers are small, tabletop devices with twin beam designs that span a wide range of wavelengths. They have silicon photodiode detectors, automatic wavelength adjustments, and tungsten and deuterium lamps. These feature LCD displays and USB ports for data storage and transportation. They provide a variety of measurement methods to satisfy various analytical needs. Our double beam spectrophotometers have exceptional performance and durability, auto calibration, user-friendly interfaces, and enhanced optics for precision.

Double Beam UV-Vis Spectrophotometer LUS-B51

Double Beam UV-Vis Spectrophotometer LUS-B51

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 5 nm
  • Wavelength Accuracy : ± 1.8 nm
  • Wavelength Repeatability : ≤ 1 nm
Double Beam UV-Visible Spectrophotometer LUS-B24

Double Beam UV-Visible Spectrophotometer LUS-B24

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 2 nm
  • Optical System : Double Beam, Grating 1200 lines/ mm
  • Wavelength Accuracy : ± 0.1nm at 656.1 nm, ± 0.3 nm at all
Double Beam UV-Vis Spectrophotometer LUS-B63

Double Beam UV-Vis Spectrophotometer LUS-B63

  • Spectral Bandwidth : 2.0nm
  • Wavelength Range : 190 to 1100 nm
  • Optical System : Quasi double beam ratio monitoring optical path, holographic diffraction grating
  • Wavelength Accuracy : ± 0.5nm
Double Beam UV-Vis Spectrophotometer LUS-B22
Double Beam UV-Vis Spectrophotometer LUS-B22
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1 nm
  • Wavelength Setting : Automatic
  • Optical System : Double Beam, Grating 1200 lines/ mm
Double Beam UV-Vis Spectrophotometer LUS-B21
Double Beam UV-Vis Spectrophotometer LUS-B21
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 2 nm
  • Wavelength Setting : Automatic
  • Optical System : Double Beam, Grating 1200 lines/ mm
Double Beam UV-Vis Spectrophotometer LUS-B12

Double Beam UV-Vis Spectrophotometer LUS-B12

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1.8 nm
  • Optical System : Double beam, C-T monochromator,1200 L/mm holographic grating
  • Wavelength Accuracy : ±0.3 nm
Double Beam UV-Vis Spectrophotometer LUS-B62

Double Beam UV-Vis Spectrophotometer LUS-B62

  • Optical System : Double beam, CT type light path, 1200 line/mm laser holographic diffraction grating
  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 0.5 nm, 1 nm, 2 nm, 4 nm, 5 nm
  • Wavelength Accuracy : ±0.3 nm (all-optical wavelength), ±0.1 nm (656.1 nm)
Double Beam UV-Vis Spectrophotometer  LUS-B28

Double Beam UV-Vis Spectrophotometer LUS-B28

  • Wavelength Range : 190 to 1100 nm
  • Spectral Bandwidth : 1 nm
  • Wavelength Setting : Automatic
  • Optical System : Double Beam, Grating 1200 lines/ mm

Double Beam UV-Vis Spectrophotometer:
Double Beam UV-Vis Spectrophotometer LUS-B51, Double Beam UV-Visible Spectrophotometer LUS-B24, Double Beam UV-Vis Spectrophotometer LUS-B63, Double Beam UV-Vis Spectrophotometer LUS-B22, Double Beam UV-Vis Spectrophotometer LUS-B21, Double Beam UV-Vis Spectrophotometer LUS-B12, Double Beam UV-Vis Spectrophotometer LUS-B62, Double Beam UV-Vis Spectrophotometer LUS-B28, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.