Labtron gas chromatography models are benchtop units designed for precise chemical analysis. They have advanced flow controllers, large LCD displays, gas flow, heating curves, and digital control modes. They can accommodate capillary and packed column systems with their huge oven capacity and quick temperature programming. These include automated flame lighting, self-diagnostic features, and twin FID detectors. These devices provide effective data processing and internet access for simple data transfer. Our GC models are built with sturdy construction, thermal insulation, and multi-phase temperature programming to provide precise and dependable analysis.
Oven: Maximum capacity22 LTemperature rangeRT + 5 ℃ to 400 ℃Temperature accuracy± 0.1 ℃Temperature program9 StepProgram total time9999.9 minMaximum Heating Rate0.1 to 60 ℃/ minMaximum Cooling Rate≤ 10 mins (250 to 50 ℃)
Sample injector: Temperature rangeRT+ 7 ℃ to 420 ℃Temperature controlIndependentInjector typeColumn or splitMaximum sample inlet3 pcsCarrier gas flow typeConstant pressurePressure range0 to 400 kPaPressure accuracy0.1 kPaMobile phase flow rangeH2: 0 to 200 ml/min, N2: 0 to 150 ml/min
Detector: TypeFID or TCDTemperature rangeRT + 7 ℃ to 420 ℃Maximum installationDual detectorFlame ignition modeAutomaticFlame Ionization Detector (FID)Logarithmic amplifier High voltage switch control Baseline signal display Ignition coil control Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane) Baseline noise: ≤ 5 × 10 - 14 A Baseline draft: ≤ 6 × 10-13 Dynamic range: 10 ⁷ RSD: ≤ 3 %Thermal Conductivity Detector(TCD)Sensitivity : 8000mV.ml/mg (Sample: n-hexadecane) Baseline noise: ≦0.5mV Baseline draft: ≤ 0.15 mV/30 min Dynamic range: 10 ⁵
Power supply: AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W
Oven: Temperature RangeRT to 450ºCTemperature Accuracy≤±0.1ºCTemperature Program16-phaseMaximum Temperature Heating Rate40ºC/min
Sample Injector: Temperature rangeRT+ 7 ℃ to 420 ℃Temperature controlAutomaticInjector typeColumn or splitMaximum sample inlet3 pcsCarrier gas flow typeConstant pressurePre column pressure range0 to 400 kPaPre column pressure accuracy0.1 kPaMobile phase flow rangeH2: 0 to 200 ml/min, N2: 0 to 150 ml/min
FID Detector: Temperature rangeRT + 7 ℃ to 420 ℃Maximum installationDual detectorFlame ignition modeAutomaticFlame Ionization Detector (FID)Logarithmic amplifier Mechanical valve Baseline signal display Ignition coil controlDetection limit≤3×10-12 g/s (Sample: n-hexadecane)Baseline drift≤1x10-13 A/30 minLinear range≥107
Power Supply: AC 110/220 V±10%, 50/60 Hz
Column Oven Volume: 300 × 280 × 170 mm³
Capillary Columns: 2 × 80m
Gas Types: He, N₂, H₂,Ar
Injection Pressure:
Oven Capacity: 22L
Oven Temperature Range: RT + 5 ℃ to 400 ℃
Oven Temperature Accuracy: ± 0.1 ℃
Temperature Program: 9 Step
Gas Types: H₂, CO, CO₂, CH₄, C₂H₄, C₂H₆, C₂H₂
Temperature Control Range: 4°C to 450°C, above room temperature
Pressure Range: 0 to 0.25 MPa
Flow Rate Range: 0 to 1000 mL/min
Gas Types: Nitrogen (N₂), Hydrogen (H₂), Air, Helium (He), Argon (Ar)
Temperature Control Range: 6 channels, 5°C to 400°C (up to 450°C for high-temperature type)
Temperature Accuracy: ±0.1°C
Heating Rate: 0.1 to 39°C/min (standard), 0.1 to 80°C/min (high-speed)
Carrier Gas: Nitrogen
Carrier Gas Purity: More than or equals to 99.99%
Quantitative Repeatability: Up to 1%
Fuel Gas: Hydrogen
Carrier Gas: Nitrogen
Temperature Control Range of Column Box: Room temperature to 450℃
Temperature Increment: 0.1℃
Temperature Accuracy: 0.01℃