Request A Quote
Gas Chromatography LGC-B11

Gas Chromatography LGC-B11

Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes. GC oven is capable of 9 temperature program ramps and hold steps, and features rapid cooling: 250 °C to 50 °C < 10 minutes. Accurate flow rate control via AFC has higher level repeatability of retention time and peak area, enabling specific level of analysis by means of dual FID detectors.
Request Quote
Oven
Maximum capacity22 L
Temperature rangeRT + 5 ℃ to 400 ℃
Temperature accuracy± 0.1 ℃
Temperature program9 Step
Program total time9999.9 min
Maximum Heating Rate0.1 to 60 ℃/ min
Maximum Cooling Rate≤ 10 mins (250 to 50 ℃)
Sample injector
Temperature rangeRT+ 7 ℃ to 420 ℃
Temperature controlIndependent
Injector typeColumn or split
Maximum sample inlet3 pcs
Carrier gas flow typeConstant pressure
Pressure range0 to 400 kPa
Pressure accuracy0.1 kPa
Mobile phase flow rangeH2: 0 to 200 ml/min, N2: 0 to 150 ml/min
Detector
TypeFID or TCD
Temperature rangeRT + 7 ℃ to 420 ℃
Maximum installationDual detector
Flame ignition modeAutomatic
Flame Ionization Detector (FID)Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane)
Baseline noise: ≤ 5 × 10 - 14 A
Baseline draft: ≤ 6 × 10-13
Dynamic range: 10 ⁷
RSD: ≤ 3 %
Thermal Conductivity Detector(TCD)Sensitivity : 8000mV.ml/mg (Sample: n-hexadecane)
Baseline noise: ≦0.5mV
Baseline draft: ≤ 0.15 mV/30 min
Dynamic range: 10 ⁵
Power supply AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W
Packing dimension 1020 × 660 × 740 mm
Gross Weight 82 kg
Net weight 70 kg
  • 7-inch LCD display specifies temperature, gas flow and heating curve
  • H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
  • Equipped with capillary analysis system and capillary split sampler
  • Injection system incorporates diaphragm cleaning, split flow and auxiliary gas adjustment
  • Standard unit for high-speed analysis with polar capillary column
  • PEG-20M and FFAP stationary phase polar capillary columns can be coupled
  • Dual FID detector with automatic flame ignition and baseline signal display
  • Self-diagnostic and automatic fault recognition function
  • Multi-core and 32-bit embedded hardware system ensures the reliable operation
  • Equipped with chromatography workstation software to process data
  • Memory function can store 20 sample test data
  • RS232 interface and LAN port
Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.
Accessories no Accessories name
1.        FID detector system
2.        Capillary injection system
3.        Chromatography workstation software
Accessories no Accessories name
1 Polar capillary columns PEG-20M
Stationary phase: 30 m × 0.32 mm
injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
2 Polar capillary columns FFAP
Stationary phase: 30 m × 0.32 mm
Injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
3 Syringe 1 ul
4 Syringe 5 ul

Models of Gas Chromatography (GC)

Labtron gas chromatography models are benchtop units designed for precise chemical analysis. They have advanced flow controllers, large LCD displays, gas flow, heating curves, and digital control modes. They can accommodate capillary and packed column systems with their huge oven capacity and quick temperature programming. These include automated flame lighting, self-diagnostic features, and twin FID detectors. These devices provide effective data processing and internet access for simple data transfer. Our GC models are built with sturdy construction, thermal insulation, and multi-phase temperature programming to provide precise and dependable analysis.

Gas Chromatography System LGC-B14

Gas Chromatography System LGC-B14

  • Oven Capacity : 22L
  • Oven Temperature Range : RT + 5 ℃ to 400 ℃
  • Oven Temperature Accuracy : ± 0.1 ℃
  • Temperature Program : 9 Step
Gas Chromatography LGC-B13

Gas Chromatography LGC-B13

  • Column Oven Volume : 300 × 280 × 170 mm³
  • Capillary Columns : 2 × 80m
  • Gas Types : He, N₂, H₂,Ar
  • Injection Pressure :
Gas Chromatography LGC-B15

Gas Chromatography LGC-B15

  • Gas Types : H₂, CO, CO₂, CH₄, C₂H₄, C₂H₆, C₂H₂
  • Temperature Control Range : 4°C to 450°C, above room temperature
  • Pressure Range : 0 to 0.25 MPa
  • Flow Rate Range : 0 to 1000 mL/min
Gas Chromatography LGC-B17
Gas Chromatography LGC-B17
  • Carrier Gas : Nitrogen
  • Carrier Gas Purity : More than or equals to 99.99%
  • Quantitative Repeatability : Up to 1%
  • Fuel Gas : Hydrogen
Gas Chromatography LGC-C10
Gas Chromatography LGC-C10
  • Column chamber temperature range : Room temperature +15°C to 399°C
  • Conversion furnace temperature range : Room temperature +30°C to 399°C
  • Thermal conductivity detector temperature range : Room temperature +30°C to 399°C
  • Thermal conductivity noise : Less than or equal to 0.05mv
Gas Chromatography LGC-B16

Gas Chromatography LGC-B16

  • Gas Types : Nitrogen (N₂), Hydrogen (H₂), Air, Helium (He), Argon (Ar)
  • Temperature Control Range : 6 channels, 5°C to 400°C (up to 450°C for high-temperature type)
  • Temperature Accuracy : ±0.1°C
  • Heating Rate : 0.1 to 39°C/min (standard), 0.1 to 80°C/min (high-speed)
Gas Chromatography LGC-B18

Gas Chromatography LGC-B18

  • Carrier Gas : Nitrogen
  • Temperature Control Range of Column Box : Room temperature to 450℃
  • Temperature Increment : 0.1℃
  • Temperature Accuracy : 0.01℃
Gas Chromatography LGC-B12

Gas Chromatography LGC-B12

  • Oven Temperature Range : RT to 450ºC
  • Oven Temperature Accuracy : ≤ ±0.1ºC
  • Oven Temperature Program : 16-phase
  • Oven Maximum Temperature Heating Rate : 40ºC/min

Gas Chromatography (GC):
Gas Chromatography System LGC-B14, Gas Chromatography LGC-B13, Gas Chromatography LGC-B15, Gas Chromatography LGC-B17, Gas Chromatography LGC-C10, Gas Chromatography LGC-B16, Gas Chromatography LGC-B18, Gas Chromatography LGC-B12, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.