Gas Chromatography LGC-B16

Gas Chromatography LGC-B16

Gas Chromatography LGC-B16 comes with an oven temperature range from 4°C to 450°C, ensuring precise thermal control for accurate analysis. Its 8-inch touchscreen provides an intuitive interface for seamless operation and monitoring. The electronic gas circuit (EPC) ensures 0.01 KPa pressure accuracy, enhancing retention time reproducibility. It supports capillary S/SL, valve, and automatic liquid injection, allowing flexible sample handling. Ideal for quantitative and qualitative analysis in laboratories and industrial settings.

Gas Chromatography LGC-B16
Gas Chromatography LGC-B16
Gas Chromatography LGC-B16
Request Quote
Gas Types Nitrogen (N₂), Hydrogen (H₂), Air, Helium (He), Argon (Ar)
Temperature Control Range 6 channels, 5°C to 400°C (up to 450°C for high-temperature type)
Temperature Accuracy ±0.1°C
Heating Rate 0.1 to 39°C/min (standard), 0.1 to 80°C/min (high-speed)
Cooling Time 260°C to 50°C in 6 minutes
Oven Temperature Control Accuracy ±0.01°C
Oven Temperature Steps 8 or 16 steps
Injection Modes Packed column, capillary S/SL, valve, auto liquid, thermal desorption, headspace, purge & trap
Pneumatic Control Manual (pressure gauge) or electronic (EPC/EFC)
EPC/EFC Control Constant current, constant voltage, shunt mode
EPC/EFC Pressure Range 0 to 0.6 kPa
EPC/EFC Flow Range 0 to 100 sccm or 0 to 500 sccm
EPC/EFC Accuracy Pressure: 0.01 kPa, Flow: 0.01 sccm
Detectors Supports up to 3 detectors
Available Detectors TCD, HTCD, uTCD, FID, FPD, ECD, NPD, ZD, PDHID, PID, AID
FID Detection Limit Less than or equal to 6×10⁻¹² g/s (n-hexadecane)
TCD Sensitivity Greater than or equal to 3000mV·ml/mg (n-hexadecane)
ECD Detection Limit Less than or equal to 1×10⁻¹³ g/ml (propane)
FPD Detection Limit (S) Less than or equal to 2×10⁻¹¹ g/s, (P) Less than or equal to 1×10⁻¹² g/s
NPD Detection Limit (N) Less than or equal to 5×10⁻¹² g/s, (P) Less than or equal to 5×10⁻¹² g/s
Display 8-inch touch screen (optional LCD)
External Events 6-way, auxiliary control 2-way
Communication Interface Ethernet (IEEE802.3) for remote control
Dimension 550 × 450 × 470 mm
Packaging Dimension 700 × 600 × 600 mm
Net Weight 45 kg
Gross Weight 55 kg
  • User-friendly touch screen interface

  • Stable retention time accuracy

  • Multi-stage pressure control system

  • Customizable valve system available

  • Compatible with N₂, H₂, He, Ar

  • Automatic method storage feature

  • High-sensitivity detector options

  • Fast cooling for efficiency

Our Gas Chromatography LGC-B16 is used in pharmaceutical research, environmental monitoring, and petrochemical analysis. It ensures precise separation of volatile compounds, enabling accurate qualitative and quantitative analysis.

Accessory NameQuantity
GC-Solution Software1 pc
Hydrogen Generator1 pc
Air Generator1 pc
Chromatographic Column1 pc
RVV Power Cable1 pc
Data Connection Line (Network Cable)1 pc
Special Pressure Reducing Valve Connector3 pcs
Microinjection Needle (0.5 µL)1 pc
Microinjection Needle (1 µL)1 pc
Microinjection Needle (10 µL)1 pc
Outer Air Path Nuts15 pcs
Outer Air Line Gasket50 pcs
Gas Line Liner12 pcs
Copper Gas Pipe20 pcs
Solid Wrench3 pcs
Phillips Screwdriver1 pc
Straight Screwdriver1 pc
Tee-Junction1 pc
Fuse12 pcs
Column Joint Nuts3 pcs
Graphite Washer20 pcs
Joint Nut (Capillary Column) (for SPL)3 pcs
Glass Liner (Through & Diffusion) (for SPL)1 pc
Capillary Rack (for SPL)1 pc
Soap Film Flowmeter (for SPL)1 pc
Sample Pad (for SPL)20 pcs
Fluorine Seal Ring (for SPL)3 pcs
Graphite Washer (for SPL)3 pcs
Small Diameter Capillary Graphite Gasket (for SPL)10 pcs
Large Diameter Capillary Graphite Gasket (for SPL)10 pcs
Capillary Column FID Joint (for SPL)1 pc
FID Column Joint (for FID)2 pcs
Accessory NameQuantity
FID (Hydrogen Flame Ionization Detector)1 pc
SPL (Split/Splitless Injector)1 pc
Chromatography Anti-control Workstation1 pc
Chromatographic Column1 pc
Liquid Autosampler (156 vial capacity)1 pc
High-purity Hydrogen Generator1 pc
Low Noise Air Pump1 pc

Models of Gas Chromatography (GC)

Labtron gas chromatography models are benchtop units designed for precise chemical analysis. They have advanced flow controllers, large LCD displays, gas flow, heating curves, and digital control modes. They can accommodate capillary and packed column systems with their huge oven capacity and quick temperature programming. These include automated flame lighting, self-diagnostic features, and twin FID detectors. These devices provide effective data processing and internet access for simple data transfer. Our GC models are built with sturdy construction, thermal insulation, and multi-phase temperature programming to provide precise and dependable analysis.

Gas Chromatography LGC-B12

Gas Chromatography LGC-B12

  • Oven : Temperature RangeRT to 450ºCTemperature Accuracy≤±0.1ºCTemperature Program16-phaseMaximum Temperature Heating Rate40ºC/min
  • Sample Injector : Temperature rangeRT+ 7 ℃ to 420 ℃Temperature controlAutomaticInjector typeColumn or splitMaximum sample inlet3 pcsCarrier gas flow typeConstant pressurePre column pressure range0 to 400 kPaPre column pressure accuracy0.1 kPaMobile phase flow rangeH2: 0 to 200 ml/min, N2: 0 to 150 ml/min
  • FID Detector : Temperature rangeRT + 7 ℃ to 420 ℃Maximum installationDual detectorFlame ignition modeAutomaticFlame Ionization Detector (FID)Logarithmic amplifier Mechanical valve Baseline signal display Ignition coil controlDetection limit≤3×10-12 g/s (Sample: n-hexadecane)Baseline drift≤1x10-13 A/30 minLinear range≥107
  • Power Supply : AC 110/220 V±10%, 50/60 Hz
Gas Chromatography LGC-B13

Gas Chromatography LGC-B13

  • Column Oven Volume : 300 × 280 × 170 mm³
  • Capillary Columns : 2 × 80m
  • Gas Types : He, N₂, H₂,Ar
  • Injection Pressure :
Gas Chromatography System LGC-B14

Gas Chromatography System LGC-B14

  • Oven Capacity : 22L
  • Oven Temperature Range : RT + 5 ℃ to 400 ℃
  • Oven Temperature Accuracy : ± 0.1 ℃
  • Temperature Program : 9 Step
Gas Chromatography LGC-B17
Gas Chromatography LGC-B17
  • Carrier Gas : Nitrogen
  • Carrier Gas Purity : More than or equals to 99.99%
  • Quantitative Repeatability : Up to 1%
  • Fuel Gas : Hydrogen
Gas Chromatography LGC-B18
Gas Chromatography LGC-B18
  • Carrier Gas : Nitrogen
  • Temperature Control Range of Column Box : Room temperature to 450℃
  • Temperature Increment : 0.1℃
  • Temperature Accuracy : 0.01℃
Gas Chromatography LGC-B11

Gas Chromatography LGC-B11

  • Oven : Maximum capacity22 LTemperature rangeRT + 5 ℃ to 400 ℃Temperature accuracy± 0.1 ℃Temperature program9 StepProgram total time9999.9 minMaximum Heating Rate0.1 to 60 ℃/ minMaximum Cooling Rate≤ 10 mins (250 to 50 ℃)
  • Sample injector : Temperature rangeRT+ 7 ℃ to 420 ℃Temperature controlIndependentInjector typeColumn or splitMaximum sample inlet3 pcsCarrier gas flow typeConstant pressurePressure range0 to 400 kPaPressure accuracy0.1 kPaMobile phase flow rangeH2: 0 to 200 ml/min, N2: 0 to 150 ml/min
  • Detector : TypeFID or TCDTemperature rangeRT + 7 ℃ to 420 ℃Maximum installationDual detectorFlame ignition modeAutomaticFlame Ionization Detector (FID)Logarithmic amplifier High voltage switch control Baseline signal display Ignition coil control Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane) Baseline noise: ≤ 5 × 10 - 14 A Baseline draft: ≤ 6 × 10-13 Dynamic range: 10 ⁷ RSD: ≤ 3 %Thermal Conductivity Detector(TCD)Sensitivity : 8000mV.ml/mg (Sample: n-hexadecane) Baseline noise: ≦0.5mV Baseline draft: ≤ 0.15 mV/30 min Dynamic range: 10 ⁵
  • Power supply : AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W
Gas Chromatography LGC-B15

Gas Chromatography LGC-B15

  • Gas Types : H₂, CO, CO₂, CH₄, C₂H₄, C₂H₆, C₂H₂
  • Temperature Control Range : 4°C to 450°C, above room temperature
  • Pressure Range : 0 to 0.25 MPa
  • Flow Rate Range : 0 to 1000 mL/min

Gas Chromatography LGC-B16 FAQ's
  • Our Gas Chromatography provides high-precision separation using advanced detectors such as FID, TCD, and ECD. Its high sensitivity and wide linear range allow for precise quantification of trace components in complex mixtures. The system ensures stable baseline performance, minimizing noise and drift for reliable results. Automated sample injection and temperature control further enhance accuracy. It is widely used in pharmaceuticals, environmental testing, and petrochemical industries for precise compound identification.

  • The Gas Chromatography includes built-in safety features such as stable pressure regulators and automatic shutoff mechanisms. The factory-set regulator pressures prevent unintentional adjustments that could affect gas flow accuracy. Users should always follow safety guidelines to minimize the risk of leaks or accidents and ensure safe operation throughout the process.

  • Labtron’s Gas Chromatography is capable of handling various gases, including hydrogen, air, and different carrier gases. Each gas has its own dedicated flow path, pressure regulators, and control mechanisms to ensure stable delivery to the system. This versatility is crucial for applications across a wide range of industries, from environmental testing to chemical analysis.

  • The Gas Chromatography enhances accuracy through precise gas flow control and temperature regulation. The EPC and EFC modules allow fine adjustments for optimal separation, improving detection efficiency. Real-time monitoring of flow and pressure ensures that conditions are ideal for accurate sample analysis, reducing the potential for errors.

  • Our Gas Chromatography requires regular maintenance to ensure optimal performance. This includes checking and cleaning flow control valves, regulators, and gas lines. Factory-set regulator pressures should not be altered to preserve calibration accuracy. Periodic inspection and recalibration are necessary to prevent issues like gas leaks or inaccurate flow measurements.

  • The Gas Chromatography uses temperature programming to improve the separation of complex mixtures. By gradually increasing the temperature, the system ensures that compounds with different boiling points elute in a controlled manner. This feature enhances resolution and minimizes the need for repeat analyses, providing better results for volatile and complex samples.

  • The Gas Chromatography’s gas flow setup should be tailored to the specific gases used in the analysis. It is important to ensure that the primary regulator pressures are stable and follow the factory settings for optimal flow accuracy. For more precise control, the use of EPC and EFC modules is recommended. Proper setup guarantees smooth operation and reliable results.

Post your question?

Our experts are here to help!

Gas Chromatography (GC):
Gas Chromatography LGC-B12, Gas Chromatography LGC-B13, Gas Chromatography System LGC-B14, Gas Chromatography LGC-B17, Gas Chromatography LGC-B18, Gas Chromatography LGC-B11, Gas Chromatography LGC-B15, and more.

Quick Links : About Us, Contact Us, User Manuals, Career, Terms of Use, Policies, Sitemap, Gallery.

Need a Product

send details for best price quotation

Click
For

Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.