Request A Quote
ICP Optical Emission Spectrometer LICP-C11

ICP Optical Emission Spectrometer LICP-C11

ICP Optical Emission Spectrometer LICP-C11 operates over a wavelength range of 165 to 1000 nm. The circuit type is a solid-state RF power supply designed with an automatic matching function to optimize power delivery and stability during operation. It uses a middle-step grating, enhancing spectral resolution and light dispersion. Our ICP Optical Emission Spectrometer includes a three-way gas control for precise adjustment of plasma, auxiliary, and carrier gas flows, enhancing overall performance and stability.

ICP Optical Emission Spectrometer LICP-C11
ICP Optical Emission Spectrometer LICP-C11
Request Quote
Wavelength Range 160 to 1000 nm
Grating Middle step grating, 52.67 lp/mm, 64° sparkle angle
Numerical Aperture F < 8, ultra-high luminous flux
Target Size 27.6 mm x 27.6 mm, 1024 x 1024 addressing detection units
Resolution < 0.0065 nm at 200 nm
Astigmatism Equivalent background concentration of 10000 ppm Ca solution at As 189.042 nm < 2 ppm
Light Chamber Precision constant temperature, 35 ± 0.1°C, nitrogen purging (normal: 1.8 L/min, fast: 3.8 L/min)
Plasma Argon Flowmeter 100 to 1000 L/h (1.6 to 16 L/min)
Auxiliary Argon Flowmeter 100 to 1000 L/h (0.16 to 1.6 L/min)
Auxiliary Carrier Argon Flowmeter 100 to 1000 L/h (0.16 to 1.6 L/min)
Pressure Maintaining Value 0 to 0.4 MPa
Cooling Water Temperature 20 to 25°C
Cooling Water Flow Rate > 5 L/min
Cooling Water Hydraulic Pressure > 0.1 MPa
Output Working Coil Inner Diameter 25 mm
Torque Tube Three concentric, external diameter 20 mm
Coaxial Nebulizer Outer diameter 6 mm
Double Barrel Atomizing Chamber Outer diameter 34 mm
Circuit Type Solid-state RF Power supply, with auto match function
Frequency 27.12 MHz ± 0.05%
Frequency Stability < 0.1%
Power Output Stability < 0.3%
Escaped RF Radiation 30 cm away from instrument, Electric Field: E < 2 V/m
Power Consumption 800 to 1500 W
Power Supply 220V, 30A
Dimension 1050 × 793 × 745mm
Packaging Dimension 1250 × 950 × 900 mm
Weight 105 Kg
Gross Weight 120Kg
  • Fully automatic matching technology
  • Stable performance
  • Sample injection automation
  • NDRO, FF, and RAI modes for flexible data logging

ICP Optical Emission Spectrometer LICP-C11 is used to analyze trace elements in substances soluble in nitric, hydrochloric, and hydrofluoric acids, in fields like environmental protection, petroleum, rare earths, semiconductors, geology, metallurgy, clinical medicine, food safety, forensics, and agriculture.

Cable × 1 line 

Plastic drum × 1 pcs 

Argon Gas Reduction × 2 pcs 

PU tube 30 m × 1 pcs

PU tube 10 m × 1 pcs 

PVC transparent tube × 1 meter 

Plug × 1 pcs 

Ground copper braided wire × 15 lines 

Brass tube × 1 pcs 

Filter element of filter tank × 4 pcs 

Capillary tube × 0.5 meter 

Torch pipe × 2 pcs 

Double cylinder fog chamber × 2 pcs 

Atomizer × 1 pcs 

Pump head hose of Peristaltic Pump (Ф1.65 L45cm) × 3 line 

Electronic Fuses(10A,250V,6×30mm) × 2 line 

Electronic Fuses (6.3A,250V,5×20mm) × 2 line 

Cylindric atomizer × 2 pcs 

Silicone tube (Inner 2mm, outer 4mm, hardness:55HRC) × 0.3 meter 

Hose adapter (ZCJH-2*6 INNER 6-2) × 4 pcs 

Hose adapter (ZC-1/16*3/32 INNER 1.6-2.4) × 4 pcs 

Spherical connector clamp- 1 pcs 

O shape seal ring (32.5×3.55) × 2 pcs 

O shape seal ring (5.6×1.8) × 4 pcs 

Quick Connector(Φ6) × 2 pcs 

Raw material belt (26mm×20m, thin:0.1~0.2mm) × 1 roll 

Ribbon × 30 line 

Toolkit- 1 set 

Computer (Lenovo) × 1 set 

Displayer (Lenovo) × 1 set 

Canon Printer (Laser printer) × 1 set 

Cooling water tank × 1 set

Automatic Sampler

Models of ICP Spectrometer

Labtron ICP Spectrometer are designed for the detection and analysis of trace and ultra-trace elements. They use advanced argon plasma technology to efficiently measure multiple elements per minute. Each unit has a highly sensitive detection system with low detection limits, providing accurate results for both liquid and solid samples. Equipped with Czerny-Turner optical pathways, these spectrometer provide exceptional optical resolution and stability. They feature advanced control systems for improved signal-to-background ratios. Our ICP Spectrometer comes with dual verniers for error reduction and optical drain sensors for enhanced sensitivity and accuracy.

ICP Spectrometer LICP-A11

ICP Spectrometer LICP-A11

  • Wavelength range : 180 to 900 nm
  • Elements per minute : 15 elements
  • Temperature : 29 °C
  • Incident slit : 25 µm
ICP Optical Emission Spectrometer LICP-C10

ICP Optical Emission Spectrometer LICP-C10

  • Wavelength Range : 165 to 950 nm
  • Observation Design : Radial and axial observation for element measurement from sub-ppm to high content
  • Optical Path Structure : Echelle grating and prism cross-dispersion with ultra-pure SiO2 prism
  • Imaging Quality : Optimized design with aspherical optical elements
ICP spectrometer LICP-A10

ICP spectrometer LICP-A10

  • Wavelength range ( 3600 lines / mm ) : 180 to 500 nm
  • Wavelength range ( 2400 lines / mm ) : 180 to 800 nm
  • Temperature : 20 ~ 28 °C
  • Elements per minute : 26 elements
ICP Spectrometer LICP-B10
ICP Spectrometer LICP-B10
  • Monochromator Specifications : Optical typeCzerny turnerResolution≤ 0.015nm (3600 line grating) ≤ 0.030nm (2400 line grating)Focal length1000 mmGrating specificationshuge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling areaWavelength range195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating
  • Solid State Power Specifications : Frequency27.12 MHz Frequency stability: < 0.05%Spray chamberScott double pass spray chamberOutput power800 W to 1600 W, adjustable with power efficiency more than 65%Output power stability≤ 0.05%Induction coil25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
  • Technical Specifications : Suitable sample content rangeLiquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%Repeatabilityshort-term stability- RSD ≤ 1.5% Long-term stability: RSD ≤ 2%Test speed5 to 8 elements / minLimits of detection (LOD, µg/L) for most elements1ppb to 10ppb
  • Control Circuit : Photomultiplier tube specificationR212 / R928Negative high voltage-50 to -1000 VCircuit measuring range(10-12 to 10 -4) ASignal acquisitionVF conversion
ICP Spectrometer LICP-A12
ICP Spectrometer LICP-A12
  • Wavelength range : 195 to 800 mm
  • Elements per minute : 10 elements
  • Temperature range : 32 °C
  • Incident slit : 20 µm

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.