| Wavelength Range | 165 to 950 nm |
| Observation Design | Radial and axial observation for element measurement from sub-ppm to high content |
| Optical Path Structure | Echelle grating and prism cross-dispersion with ultra-pure SiO2 prism |
| Imaging Quality | Optimized design with aspherical optical elements |
| Light Chamber Technology | Multi-point filling for faster operation |
| Gas Path | Independent gas path for nitrogen or argon |
| Spectroscopic System | Medium-step 2D optical system with 400 mm focal length |
| Grating Specifications | Echelle grating, 100 × 50 mm |
| Stray Light | Equivalent background concentration < 2 μg/ml at As 189.042 nm |
| Temperature Control | 38 ± 0.1℃ |
| Detector Type | Large-area CCD, full-spectrum response, high UV quantization efficiency |
| Detector Pixel | 1024 × 1024 pixels, 24 × 24 μm pixel area |
| Detector Working Temperature | < -40℃, stabilization time < 3 minutes |
| Detector Quantization Efficiency | > 75% without coating |
| Type | All-solid-state RF generator |
| RF Generator Cold Cone Tail Flame Technology | Minimizes self-absorption and ionization interference |
| RF Generator Power Output | 700W to 1600W, continuously adjustable by 1W |
| RF Generator Power Stability | ≤ 0.1% |
| RF Generator Oscillation Frequency | 27.12 MHz |
| RF Generator Frequency Stability | ≤ 0.01% |
| RF Generator Electromagnetic Field Leakage | < 0.5 V/m |
| Sampling Systems | Optimized for organic solvents, high-salt/complex matrix samples |
| Feedback Diverter System | Two-inlet and six-out waterway for better control |
| Peristaltic Pump | 4-channel, 12-roller with adjustable speed |
| Argon Gas Consumption | 8 L/min to 18 L/min |
| Cooling Gas | 0.00 L/min to 20.00 L/min, accuracy 0.01 L/min |
| Auxiliary and Carrier Gas | 0.00 L/min to 2.00 L/min, accuracy 0.01 L/min |
| Multi-Method Analysis | Supports simultaneous measurement, editing, and viewing |
| Spectral Line Library | > 70,000 spectral lines, intelligent interference prompts |
| Method Support | Standard curve and standard addition methods, multiple data processing methods |
| Report Output | Multiple formats available |
| Liquid Content Range | 0.01 ppm to several thousand ppm |
| Solid Content Range | 0.001% to 70% |
| Repeatability | RSD < 1% |
| Stability | RSD < 1.5% @ 2 hrs |
| Element Detection Limit | 1 to 10 ppb for most elements |
| Storage and Transportation Temperature | 5℃ to 40℃ |
| Storage Relative Humidity | ≤ 85% |
| Atmospheric Pressure | 86 to 106 kPa |
| Working Humidity | ≤ 70% |
| Working Temperature | 15℃ to 30℃ |
| Power Supply | 220 ± 22 VAC, 50 ± 1 Hz |
| Net Dimension | 1270 × 720 × 850 mm |
| Gross Dimension | 1500 × 900 × 1060 mm |
| Net Weight | 192.4 Kg |
| Gross Weight | 249.5 Kg |
Labtron ICP Spectrometer are designed for the detection and analysis of trace and ultra-trace elements. They use advanced argon plasma technology to efficiently measure multiple elements per minute. Each unit has a highly sensitive detection system with low detection limits, providing accurate results for both liquid and solid samples. Equipped with Czerny-Turner optical pathways, these spectrometer provide exceptional optical resolution and stability. They feature advanced control systems for improved signal-to-background ratios. Our ICP Spectrometer comes with dual verniers for error reduction and optical drain sensors for enhanced sensitivity and accuracy.