Bench-top Standard Freeze Dryer LBFD-A14 is equipped with a condenser that operates at -70°C, supporting a capacity of up to 3 kg of ice. It features a bell-shaped acrylic freeze-dried chamber. The freeze dryer’s intelligent control system with 5.4-inch touchscreen LCD, displays all major parameters in real time. Additionally, it incorporates automatic reminders for equipment maintenance and vacuum pump oil replacement. Our freeze dryer is designed for efficient and safe lyophilization in research and small-scale applications.
Condenser Temperature | - 70℃ |
Condenser Capacity | 3 kg |
Cold Trap Volume | 5 L |
Freeze-Dried Chamber Type | Bell shape acrylic chamber |
Vacuum Level | 5×10⁻³ mbar |
Pumping Capacity | 8 m³/h |
Sample Shelf Diameter | Φ200 mm |
Shelf Area (Single Layer) | 0.03 m² |
Shelf Layers (Optional) | 3 to 5 layers |
Anti-Corrosive Treatment | PTFE-coated trap and coil (standard) |
Vacuum Pump Pipe Connection | Single stainless steel flexible pipe |
Power Consumption | 600 W |
Power Supply | 220 V / 50 Hz |
Dimensions | 420 × 545 × 455 mm |
Weight | 50 kg |
One-click operation
User-defined cold trap precooling timers
User-defined pump preheating timers
Automatic display of system status
Powerful compressor
Durable structure
Our Bench-top Standard Freeze Dryer LBFD-A14 is ideal for freeze-drying small batches of biological samples, pharmaceuticals, and lab reagents. It is suitable for research labs handling aqueous or solvent-based materials requiring vacuum dehydration.
Two-stage Rotary Vane Pump I (Ultimate Vacuum: 5 × 10-3 mbar, Pumping Rate: 8 m3/h) × 1
Sr. No. | Name | Specifications |
1 | Two-stage Rotary Vane Pump I | Ultimate Vacuum: 5 × 10-3 mbar Pumping Rate: 8 m3/h |
2 | Two-stage Rotary Vane Pump II | Ultimate Vacuum: 5 × 10-3 mbar Air extraction Rate: 10 m3/h |
3 | Two-stage rotary Vane Pump III | Ultimate Vacuum: 2 × 10-3 mbar Pumping Rate: 6 m3/h |
4 | Two-stage rotary Vane Pump 1V | Ultimate Vacuum: 2 × 10-3 mbar Pumping Rate: 5.7 m3/h |
5 | Chemical Corrosion-proof Vacuum Pump | Ultimate Vacuum: 2 × 10-3 mbar Pumping Rate: 8 m3/h |
6 | Chemical Hybrid pump | Ultimate Vacuum: 2 × 10-3 mbar Air extraction Rate: 5.9 m3/h |
7 | Scroll Dry Pump | Ultimate Vacuum: 2 × 10-2 mbar Pumping Rate: 6.2 m3/h |
8 | Vacuum Pump Oil (5 L) | 5 L/barrel |
9 | Stainless steel sample tray | Experimental |
Eutectic point detection function
Data Output and analysis system
Cold trap defrost function
Download catalog for
Bench-top Standard Freeze Dryer LBFD-A14 Catalog
Available Range :
Bench-top Top Press Freeze Dryer LBFD-C10 : - 50 °C Bench-top Manifold Top Press Freeze Dryer LBFD-E10 : - 50°C Bench-top Standard Freeze Dryer LBFD-A14 : - 70℃ Bench-top Top Press Freeze Dryer LBFD-C11 : - 80 °C Bench-top Manifold Top Press Freeze Dryer LBFD-E11 : - 80°C Bench-top Standard Freeze Dryer LBFD-A16 : - 90℃ Bench-top Standard Freeze Dryer LBFD-A12 : -100℃ Bench-top T-type Freeze Dryer LBFD-B10 : -50°C Bench-top T-type Freeze Dryer LBFD-B12 : -56°C Bench-top Standard Freeze Dryer LBFD-A17 : -60°C (optional -80°C) Bench-top Manifold Freeze Dryer LBFD-D11 : -80 °CLabtron Laboratory Bench-top Freeze Dryer offers compact, desktop-sized unit of temperature ranging from -50℃ to -100℃. Their moisture sensors provide accurate readings, ensuring correct monitoring throughout cycle. They offer automatic defrosting capabilities, reducing manual intervention and ensuring consistent freeze-drying efficiency. Their safety interlocks prevent accidental operation, enhancing user safety during process. Our Laboratory Bench-top Freeze Dryer is ideal for preserving sensitive biological materials like enzymes, proteins, tissues, pharmaceuticals and food samples.
Labtron’s Standard Freeze Dryer is primarily used for lyophilizing small volumes of biological materials, pharmaceuticals, chemical samples, or lab reagents. It is especially suitable for applications in research laboratories and academic institutions where precise control over temperature and vacuum is needed for drying heat-sensitive substances. The system allows for gentle dehydration of aqueous or solvent-based samples without affecting their structure or activity, making it ideal for long-term storage or analytical preparation.
Yes, our Standard Freeze Dryer is well-equipped to handle corrosive or organic solvents, thanks to its standard Teflon anti-corrosion coating on the cold trap and condensing coil. Additionally, users can choose an optional 316L stainless steel drying chamber with a black Teflon coating, which is specifically designed for use with aggressive solvents. This makes it safe for working with a wide range of chemical compounds that might otherwise degrade unprotected internal components.
The acrylic chamber is ideal for users who are looking for a simple, cost-effective freeze-dryer for shelf-based drying. It is best suited for educational institutions, quality control labs, clinical settings, or small research setups that do not require the flexibility of external sample port connections. If the samples being freeze-dried are simple, non-corrosive, and placed directly on trays, this configuration provides more than enough functionality. It’s also ideal when ease of operation and clear visibility of the drying process are key priorities.
Our Standard Freeze Dryer comes with several built-in safety and monitoring features to ensure stable and reliable operation. These include thermal electromagnetic over-current and short-circuit protection, which guard against electrical faults. The system also monitors ambient temperature and will issue an alarm if the environment becomes too hot, potentially compromising system performance. Additionally, it actively reminds users of upcoming maintenance schedules and vacuum pump oil replacement needs, ensuring the equipment stays in top condition.
Yes, advanced monitoring and analysis features are available as optional upgrades. The Standard Freeze Dryer can be equipped with a eutectic point detection device, which helps identify the optimal freeze-drying temperature for complex samples. An endpoint judgment detection system is also available, which can automatically determine when drying is complete, improving process efficiency and consistency. For research purposes, data output and analysis functionality can be added to help track performance and document results.
Post your question?
Our experts are here to help!
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom