Bench-top Standard Freeze Dryer LBFD-A16 has a condenser that operates at -90°C, supporting a capacity of up to 6 kg of ice. It offers users to set timers for cold trap precooling and pump preheating. The freeze dryer has one-click operation for speed efficiency and operation simplicity. Additionally, it allows for optional co-crystallization point detection devices and end point judgment detection system. Our freeze dryer is suitable for freeze-drying biological and chemical samples.
Condenser Temperature | - 90℃ |
Condenser Capacity | 6 kg |
Cold Trap Volume | 10 L |
Freeze-Dried Chamber Type | Bell shape acrylic chamber |
Vacuum Level | 5×10⁻³ mbar |
Pumping Capacity | 8 m³/h |
Sample Shelf Diameter | Φ 260 mm |
Shelf Area (Single Layer) | 0.55 m² |
Shelf Layers (Optional) | 3 to 10 layers |
Anti-Corrosive Treatment | PTFE-coated trap and coil (standard) |
Vacuum Pump Pipe Connection | Single stainless steel flexible pipe |
Power Consumption | 1500 W |
Power Supply | 220 V / 50 Hz |
Dimensions | 510 × 570 × 500 mm |
Weight | 65 kg |
One-click operation
Color-coded numeric status display
Cold trap defrost function
Maintenance and vacuum pump oil replacement reminders
User-friendly interface
Short circuit protection
Our Bench-top Standard Freeze Dryer LBFD-A16 is ideal for lyophilizing pharmaceuticals, biological samples, and heat-sensitive materials. It is especially suitable for processing organic solvents and corrosive substances in research, medical, and industrial labs.
Two-stage Rotary Vane Pump I (Ultimate Vacuum: 5 × 10-3 mbar, Pumping Rate: 8 m3/h) × 1
Sr. No. | Name | Specifications |
1 | Two-stage Rotary Vane Pump I | Ultimate Vacuum: 5 × 10-3 mbar Pumping Rate: 8 m3/h |
2 | Two-stage Rotary Vane Pump II | Ultimate Vacuum: 5 × 10-3 mbar Air extraction Rate: 10 m3/h |
3 | Two-stage Rotary Vane Pump III | Ultimate Vacuum: 2 × 10-3 mbar Pumping Rate: 6 m3/h |
4 | Two-stage Rotary Vane Pump 1V | Ultimate Vacuum: 2 × 10-3 mbar Pumping Rate: 5.7 m3/h |
5 | Chemical Corrosion-proof Vacuum Pump | Ultimate Vacuum: 2 × 10-3 mbar Pumping Rate: 8 m3/h |
6 | Chemical Hybrid pump | Ultimate Vacuum: 2 × 10-3 mbar Air extraction Rate: 5.9 m3/h |
7 | Scroll Dry Pump | Ultimate Vacuum: 2 × 10-2 mbar Pumping Rate: 6.2 m3/h |
8 | Vacuum Pump Oil (5 L) | 5 L/barrel |
9 | Stainless steel sample tray | Experimental |
10 | Electric heated shelves | Փ 200 mm |
11 | Capping device (vial) | Vial |
Eutectic point detection function
Data Output and analysis system
Download catalog for
Bench-top Standard Freeze Dryer LBFD-A16 Catalog
Available Range :
Bench-top Top Press Freeze Dryer LBFD-C10 : - 50 °C Bench-top Manifold Top Press Freeze Dryer LBFD-E10 : - 50°C Bench-top Standard Freeze Dryer LBFD-A14 : - 70℃ Bench-top Top Press Freeze Dryer LBFD-C11 : - 80 °C Bench-top Manifold Top Press Freeze Dryer LBFD-E11 : - 80°C Bench-top Standard Freeze Dryer LBFD-A16 : - 90℃ Bench-top Standard Freeze Dryer LBFD-A12 : -100℃ Bench-top T-type Freeze Dryer LBFD-B10 : -50°C Bench-top T-type Freeze Dryer LBFD-B12 : -56°C Bench-top Standard Freeze Dryer LBFD-A17 : -60°C (optional -80°C) Bench-top Manifold Freeze Dryer LBFD-D11 : -80 °CLabtron Laboratory Bench-top Freeze Dryer offers compact, desktop-sized unit of temperature ranging from -50℃ to -100℃. Their moisture sensors provide accurate readings, ensuring correct monitoring throughout cycle. They offer automatic defrosting capabilities, reducing manual intervention and ensuring consistent freeze-drying efficiency. Their safety interlocks prevent accidental operation, enhancing user safety during process. Our Laboratory Bench-top Freeze Dryer is ideal for preserving sensitive biological materials like enzymes, proteins, tissues, pharmaceuticals and food samples.
Labtron’s Bench-top Standard Freeze Dryer is primarily used for lyophilizing biological materials, pharmaceuticals, chemical samples, or lab reagents. It is especially suitable for applications in research laboratories and academic institutions where precise control over temperature and vacuum is needed for drying heat-sensitive substances. The system allows for gentle dehydration of aqueous or solvent-based samples without affecting their structure or activity, making it ideal for long-term storage or analytical preparation.
Yes, our Bench-top Standard Freeze Dryer is well-equipped to handle corrosive or organic solvents, thanks to its standard Teflon anti-corrosion coating on the cold trap and condensing coil. Additionally, users can choose an optional 316L stainless steel drying chamber with a black Teflon coating, which is specifically designed for use with aggressive solvents. This makes it safe for working with a wide range of chemical compounds that might otherwise degrade unprotected internal components.
It has a bell-shaped acrylic chamber utilizes sample shelves or trays for freeze-drying. This design is well-suited for samples that are arranged in flat or tray-based configurations. Its structure is optimized to evenly distribute temperature and vacuum conditions over the sample surface, ensuring efficient and uniform drying. The chamber's layout facilitates the accommodation of multiple trays simultaneously, making it an ideal choice for laboratories or production settings where consistency and space utilization are important.
Our Bench-top Standard Freeze Dryer comes with several built-in safety and monitoring features to ensure stable and reliable operation. These include thermal electromagnetic over-current and short-circuit protection, which guard against electrical faults. The system also monitors ambient temperature and will issue an alarm if the environment becomes too hot, potentially compromising system performance. Additionally, it actively reminds users of upcoming maintenance schedules and vacuum pump oil replacement needs, ensuring the equipment stays in top condition.
Yes, advanced monitoring and analysis features are available as optional upgrades. The Bench-top Standard Freeze Dryer can be equipped with a eutectic point detection device, which helps identify the optimal freeze-drying temperature for complex samples. An endpoint judgment detection system is also available, which can automatically determine when drying is complete, improving process efficiency and consistency. For research purposes, data output and analysis functionality can be added to help track performance and document results.
Post your question?
Our experts are here to help!
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608