Low Speed Centrifuge LLS-E12 capacity of 6 × 50 ml for high performance. Its programmable speed settings allow for customized operations. It is built with corrosion-resistant materials. Its efficient heat dissipation system prevents overheating. Our low-speed centrifuge supports voltage compatibility for global use across various lab infrastructures.

Low Speed Centrifuge LLS-E12_Front View (1)
Low Speed Centrifuge LLS-E12_Front View (2)
Low Speed Centrifuge LLS-E12_Side View (1)
Request Quote
Capacity 6 × 50 ml
RCF 1788 g
Speed 500 to 4000 rpm
Time 0 to 99 mins 59 sec
Voltage 110 to 220 v 50/60 hz
Power Consumption 150 W
Dimensions (L × W × H) 390 × 320 × 270 mm
Net Weight 10.5 kg
  • High-Speed Bearings

  • Automatic Fault Detection

  • Open-Lid Protection

  • Quick Sample Processing

  • Consistent Speed Control

Low Speed Centrifuge LLS-E12 is a lab instrument that separates components of a mixture based on density. It does this by spinning samples at relatively low speed, making it ideal for gentle separations like blood cells or large particles.

Models of Low Speed Centrifuge

Labtron Low Speed Centrifuge provide separation of substances of different densities within liquid upto 6000rpm. They are equipped with fixed-angle or swing-out rotors, which determine positioning of specimens and their effective segregation. Their components include motor that drives spindles at controlled, less velocity rotation for efficient partitioning. They include cooling mechanism to maintain integrity during prolonged processes. Our Low Speed Centrifuge isolates proteins from cell lysates, assists sedimentation of bacterial cells and medicine formulation.

Low-Speed Centrifuge LLS-A57

Low-Speed Centrifuge LLS-A57

  • Maximum Capacity : 6 ×100 ml
  • Maximum Speed : 6000 rpm
  • Maximum RCF : 3660 × g
  • Time Range : 0 to 99 min
Low Speed Centrifuge LLS-D11

Low Speed Centrifuge LLS-D11

  • Speed Range : 300 to 4000 rpm in 100 rpm increment
  • Max. RCF : 1900×g
  • Speed Accuracy : ±100 rpm
  • Rotor Type : Angle Rotor
Low Speed Centrifuge LLS-E15

Low Speed Centrifuge LLS-E15

  • Capacity : 12 × 15 ml
  • RCF : 2146 g
  • Speed : 500 to 4000 rpm
  • Voltage : 110 to 220 v 50/60 hz
Low Speed Centrifuge LLS-A21
Low Speed Centrifuge LLS-A21
  • Max Speed : 5500rpm
  • Max RCF : 4919×g
  • Max Capacity : 4×250ml
  • Timer : 1s to 99h 59min 59s
Low Speed Centrifuge LLS-G27
Low Speed Centrifuge LLS-G27
  • Maximum Speed : 4000 r/min
  • Maximum RCF : 2680 g
  • Time : 0 to 99 min
  • Motor : Microprocessor & Brushless Converter Motor
Low Speed Centrifuge LLS-A54

Low Speed Centrifuge LLS-A54

  • Maximum Speed : 5000 rpm
  • Maximum RCF : 4730×g
  • Maximum Capacity : 4×300 ml
  • Time Range : 0 to 99 min
Low Speed Centrifuge LLS-C10

Low Speed Centrifuge LLS-C10

  • Rotation Speed Range : 500 to 5000 rpm
  • Speed Regulation Accuracy : ± 30 rpm
  • Max RCF : 3074 × g
  • Rotor Capacity : Centrifuge tube : 15 mL × 6
Low Speed Centrifuge LLS-F12

Low Speed Centrifuge LLS-F12

  • Capacity : 6 × 15 ml
  • RCF : 1920 g
  • Speed : 500 to 4000 rpm
  • Time : 0 to 99 mins 59 sec
Low Speed Centrifuge LLS-E12 FAQ's
  • Labtron designs the LLS-E12 centrifuge chamber and rotor using high-quality, corrosion-resistant metals, often aluminum alloy or stainless steel. These materials ensure long-term durability, resistance to chemicals and biological agents, and easy decontamination. The non-corrosive nature of these components allows users to perform various biological, clinical, and chemical protocols without worrying about long-term wear. Moreover, these materials support high-speed rotation without deformation, making the system both structurally sound and efficient for everyday laboratory use.

  • Yes, the Labtron LLS-E12 is suitable for preparing Platelet-Rich Plasma (PRP), especially in medical, dermatological, and cosmetic applications. Due to its low-speed settings and the ability to precisely adjust time and RPM, it allows for a gentle separation of platelets from red and white blood cells. The preservation of platelet integrity is crucial for therapeutic uses, and the LLS-E12's consistent and gentle centrifugation is well-suited for this process. Additionally, its compact size and ease of use make it ideal for clinics and outpatient settings.

  • Yes, Labtron’s LLS-E12 is designed for easy cleaning and low maintenance. Its internal chamber and rotor are constructed from corrosion-resistant materials that can be wiped down with mild detergent and water. Removable rotors and tube holders make it easy to clean hard-to-reach areas. Routine maintenance involves inspecting the rotor for cracks or corrosion, ensuring that the lid lock functions properly, and checking for debris in the chamber. Because the centrifuge uses a brushless motor, there is no need to replace motor brushes, reducing the overall maintenance workload. Proper care and regular cleaning can significantly extend the lifespan of the instrument.

  • Labtron’s LLS-E12 is widely used in clinical and research laboratories for a variety of applications. These include blood component separation (e.g., plasma, serum), urine sedimentation analysis, protein precipitation, cell pelleting, and general sample clarification. It is also employed in food safety testing, environmental monitoring, and veterinary diagnostics. Its gentle yet effective spinning action makes it particularly useful for handling fragile samples that could be damaged by high-speed centrifugation. In academic settings, it is used for teaching basic principles of centrifugal force and separation techniques.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.