Request A Quote
Low Temperature Circulating Chiller LLTC-C13

Low Temperature Circulating Chiller LLTC-C13

Low Temperature Circulating Chiller LLTC-C13 offers a temperature range of -45°C to 20°C for efficient cooling. Its multi-stage cooling process ensures uniform temperature and coolant distribution. It has an integrated safety shutdown feature enhancing operational protection. The system is engineered for reliable performance in continuous and demanding laboratory or industrial applications. Our chiller supports thermal management in semiconductor manufacturing, medical imaging devices, and analytical instrumentation.

Request Quote
Temperature Range -45°C to 20°C
Temperature Control ±0.5°C
Circulation Pump Max 4.5m³/h 2 bar
Refrigerant R448A
Cooling Capacity at -20°C 18.5 kW
Cooling Capacity at -35°C 10.8 kW
Power 400V 50HZ / 460V 60HZ
  • Auto-Tuning for Optimal Performance
  • Low Power Consumption Mode
  • Superior Heat Transfer Efficiency
  • High Thermal Conductivity
  • Wide Operational Temperature Range

Our Low Temperature Circulating Chiller is used in semiconductor manufacturing, medical imaging, pharmaceutical processing, and environmental testing labs for consistent low-temperature control, thermal management, and precision cooling in sensitive applications.

Low Temperature Circulating Chiller LLTC-C13 | Circulation Pump Max : 4.5m³/h 2 bar | Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-C13 | Superior Heat Transfer Efficiency | High Thermal Conductivity

Models of Low Temperature Circulating Chillers

Labtron Low Temperature Circulating Chillers offer precise temperature control and reliable cooling for laboratory, industrial, and research applications. Their advanced refrigeration systems ensure consistent low-temperature circulation. These chillers feature high-quality components, intuitive controls, and durable construction for efficient thermal management. They operate reliably under varying load conditions, even in continuous or high-demand use. Our chillers are ideal for cooling rotary evaporators, distillation systems, and spectroscopy instruments.

Low Temperature Circulating Chiller LLTC-A15

Low Temperature Circulating Chiller LLTC-A15

  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 28m³/h 2 bar
  • Refrigerant : R410A/R134A
Low Temperature Circulating Chiller LLTC-E14

Low Temperature Circulating Chiller LLTC-E14

  • Temperature Range : -80°C to -50°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 11m³/h 2 bar
  • Refrigerant : R448A/R508B/R23
Low Temperature Circulating Chiller LLTC-G12

Low Temperature Circulating Chiller LLTC-G12

  • Temperature Range : 5°C to 90°C
  • Temperature Control : PLC controller, control the water tank outlet temperature
  • Temperature Control Accuracy : ±0.3°C
  • Circulation Pump Max : 50L/min 2 bar
Low Temperature Circulating Chiller LLTC-C11
Low Temperature Circulating Chiller LLTC-C11
  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 2.4m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-D15
Low Temperature Circulating Chiller LLTC-D15
  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 12.1m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-H10

Low Temperature Circulating Chiller LLTC-H10

  • Temperature Range : -40°C to 90°C
  • Temperature Control : ±0.3°C
  • Circulation Pump Max : 20L/min 2 bar
  • Refrigerant : R-448A/R507C
Low Temperature Circulating Chiller LLTC-A14

Low Temperature Circulating Chiller LLTC-A14

  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 19m³/h 2 bar
  • Refrigerant : R410A/R134A
Low Temperature Circulating Chiller LLTC-E11

Low Temperature Circulating Chiller LLTC-E11

  • Temperature Range : -80°C to -50°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 3.4m³/h 2 bar
  • Refrigerant : R448A/R508B/R23
Low Temperature Circulating Chiller LLTC-C13 FAQ's
  • The chiller uses a multi-stage cooling process that ensures uniform temperature distribution and consistent coolant flow for reliable performance. This system also adapts to varying cooling loads, maintaining stable temperatures even in fluctuating conditions. The built-in temperature control mechanism further enhances precision. Additionally, the chillers advanced design helps reduce thermal gradients, ensuring even cooling across all connected systems.

  • Yes, it is engineered for reliable performance in both continuous and demanding laboratory and industrial applications. Its robust construction ensures durability in harsh environments, withstanding the challenges of high workloads and long operational hours. The chiller is designed to maintain stable temperatures even under extreme conditions, making it ideal for use in industrial settings. It also features a compact design for easy integration into existing setups without sacrificing cooling performance.

  • The Low Temperature Circulating Chiller features an automatic restart function that resumes cooling after a power failure, minimizing downtime. This ensures that cooling is restored promptly, preventing any disruptions in critical processes. The chiller is equipped with built-in safety mechanisms to protect the system during power outages. It also logs fault occurrences, allowing for easy troubleshooting and maintenance after a power failure.

  • Yes, it features programmable settings that allow for customized temperature control schedules, tailored to meet specific cooling requirements. Users can adjust temperature ranges and set operational parameters to optimize performance for different applications. The flexibility of the settings ensures the chiller can handle unique cooling demands across various industries. Additionally, the chiller supports remote monitoring for easy adjustments and tracking of performance.

  • Yes, it is designed to integrate seamlessly with other systems requiring consistent low temperatures, such as chromatographs, reactors, and medical equipment. The chiller provides stable and reliable cooling, ensuring optimal performance for a variety of applications. Its flexible connectivity options make it easy to incorporate into existing setups, improving the overall efficiency of your cooling system. The system’s versatility also allows it to support a wide range of industries, from research labs to industrial manufacturing.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.