Microplate Reader LMPR-A15 offers exceptional accuracy (±0.008A) and stability (±0.003A) across a broad wavelength range. It has high-speed reading (≤3s) and a built-in thermal printer to get you from sample to report in record time. The reader features a stable internal memory that can store up to twenty million test data points. This microplate reader supports the connection of a keyboard and mouse for easy data entry (USB-A). Our LMPR-A15 is a versatile instrument designed for a wide range of laboratory applications. 

Request Quote
Microplate types 96/48 - well plate
Photodetector Silicon Photodiode
Light source 8v/50w Controlled tungsten halogen lamp
Wavelength range 400nm~800nm
Standard filters 405, 450, 492, 630nm
Optional filters 4 optional filters available
Reading range 0.000~4.000A
Resolution 0.001A
Accuracy ±0.008A
Reproducibility ≤0.2%
Stability ±0.003A
Reading Speed (Single Wavelength) ≤3s
Reading Speed (Double Wavelength) ≤6s
Shaking Linear Shaking
Shaking Speeds 3 speeds
Printer Built-in Thermal Printer (optional); supports external printer
Interface connections DVI, VGA, LAN, USB-A, USB-B, USB-C, AUDIO, RS-232
Display 10.4
Display Resolution 1024*600
Data Storage Capacity Up to twenty million test data
Test Project Capacity 500 test projects
Power supply 100~240V, 50~60Hz
Dimensions 460mm × 350mm × 197mm
Net weight 8kg
  • High-resolution display

  • Controlled light source

  • Auto lamp adjustment

  • High-quality photodetector

  • Data analysis based on cut-offs

  • Large intelligent operation interface

  • Features automatic calibration routines

  • Memory can hold up to 500 individual test projects

Our Microplate Reader LMPR-A15 excels in applications that demand robust data evaluation, from simple qualitative tests to complex quantitative analysis. It is perfectly applied in pharmaceutical development for drug discovery assays, quality control (QC) testing in industrial settings, and academic research involving kinetic studies.

Microplate Reader LMPR-A15
Microplate Reader LMPR-A15

Models of Microplate Reader

Labtron Microplate Readers have multiple wells (commonly 48, 96, 384, or 1536) that serve as small test tubes. These are used to detect biological, chemical, or physical events in samples within microtiter plates. Our advanced models offer a range of wavelengths, allowing users to customize the absorbance or fluorescence measurements according to specific requirements. With their high sensitivity and dynamic range, they are capable of detecting very low and high signals. They come with specialized software for controlling the reader, setting up protocols, and analyzing the collected data. To ensure that reagents and samples are well-mixed before measurement, our microplate readers include shaking or stirring functions.

Microplate Reader LMPR-A21

Microplate Reader LMPR-A21

  • Microplate types : 96/48 -well plate
  • Photodetector : Silicon Photodiode
  • Light source : 8V/50W Controlled tungsten halogen lamp or LED light
  • Wavelength range : 400nm to 800nm
Microplate Reader LMPR-C10

Microplate Reader LMPR-C10

  • Wavelength Range : 340 to 750 nm
  • Filter Bandwidth : 8 to 10 nm
  • Wavelength Accuracy : Less than or equal to ±2 nm
  • Absorbance Range : 0 to 4.000Abs
Multi-Mode Microplate Reader LMMR-A10

Multi-Mode Microplate Reader LMMR-A10

  • Microplate Types : Supports 6 to 384 well plates; 96-well included
  • Light source : Xenon lamp
  • Temperature Control : RT +4 °C to 45 °C ± 0.5 °C at 37 °C
  • Dynamic Range : 0 to 4 OD range supported
Microplate Reader LMPR-B10
Microplate Reader LMPR-B10
  • Light Source : Xenon flash lamp (10⁹ flashes lifespan)
  • Wavelength Range : 200 to 1000 nm
  • Wavelength Selection : Grating monochromator
  • Wavelength Increment : 1 nm
Microplate Reader LMPR-A17
Microplate Reader LMPR-A17
  • Microplate types : 96/48 -well plate
  • Photodetector : Silicon Photodiode
  • Light source : 8V/50W Controlled tungsten halogen lamp or LED light
  • Wavelength range : 400nm to 800nm
Microplate Reader LMPR-A14

Microplate Reader LMPR-A14

  • Wavelength range : 200 nm to 1000 nm with 1 nm steps
  • Wavelength accuracy : ±2 nm
  • Wavelength selection : Monochromator
  • Half-bandwidth of filter : ˂ 2.5 nm
Microplate Reader LMPR-A30

Microplate Reader LMPR-A30

  • Plate type : 48/96-well plate
  • Wavelength range : 400-850 nm
  • Standard filters : 405, 450, 492, 630 nm
  • Additional filters : Filter wheel for up to 8 filters
Microplate Reader LMPR-A11

Microplate Reader LMPR-A11

  • Plate Type : 96-well Plate
  • Readout Range : 0.000 to 3.500Abs
  • Wavelength : 405, 450, 492, 630nm, Two more optional
  • Stability :

Microplate Reader LMPR-A15 FAQ's
  • Our product can be used to conduct all types of colorimetric assays, bacterial growth assays, ELISA, nucleic acid and protein identification as well as quantification and much more.

  • Yes, the software associated with our microplate reader provides a means for the data generated to be used for data analysis in Excel.

  • A Microplate Reader, commonly called as plate reader or plate spectrophotometer, is an analytical instrument that reads or detects the physical, chemical, and biological events of the analyte, within the wells of the plate. It has numerous tiny wells where the sample analyte is introduced for analysis.

  • A standard spectrophotometer measures the absorbance of one sample at a time. The sample is typically placed in a cuvette through which light is sent horizontally. An absorbance plate reader offers higher throughput and can measure the absorbance of samples in microplates (typically 96-well or even 384-well) by sending light through each well vertically.

  • Microplate-based measurements detect light signals produced by a sample, converted by a sample, or transmitted through a sample. In the plate reader, the signal is measured by a detector, usually a photomultiplier tube (PMT). PMTs convert photons into electricity that is then quantified by the microplate reader. The output of this process is numbers by which a sample is quantified.

  • Tungsten-halogen or xenon flash lamps are generally used. LEDs have also come into the picture in some modern readers.

  • The detection technology can be of 3 types- Monochromator based detection which provides flexibility, convenience, and spectral scanning; Filter based detection which enables rapid switch between different wavelengths; Hybrid detection which has dual technological advantage of both flexibility and sensitivity.

Post your question?

Our experts are here to help!

Microplate Reader:
Microplate Reader LMPR-A21, Microplate Reader LMPR-C10, Multi-Mode Microplate Reader LMMR-A10, Microplate Reader LMPR-B10, Microplate Reader LMPR-A17, Microplate Reader LMPR-A14, Microplate Reader LMPR-A30, Microplate Reader LMPR-A11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.