Request A Quote
Microplate Reader LMPR-A16

Microplate Reader LMPR-A16

Microplate Reader LMPR-A16 operates within a wavelength range of 400nm to 800nm for optimal performance. The device can perform 12 different tests simultaneously on a single plate. It has auto lamp adjustment and calibration to enhance efficiency and reduce costs. Its built-in and external printer support ensures convenient result documentation. Our reader is ideal for diverse labs for disease diagnosis, biomedical research, and vaccine development.

Microplate Reader LMPR-A16_Side view
Microplate Reader LMPR-A16_front view
Request Quote
Microplate types 96/48 -well plate
Photodetector Silicon Photodiode
Light source 8V/50W Controlled tungsten halogen lamp or LED light
Wavelength range 400nm to 800nm
Standard filters 405,450,492,630nm and 4 optional
Reading range 0.000 to 4.000A
Resolution 0.001A
Accuracy ±0.008A
Reproducibility ≤0.2%
Stability ±0.003A
Shaking Linear Shaking, 3 speeds
Interface connections USB
Power supply 100 to 240V, 50 to 60Hz
  • Dual Wavelength Analysis
  • 8-Channel Optical Scanning
  • Massive Data Storage
  • Comprehensive Report Output
  • USB PC Connectivity

Our Microplate Reader is ideal for diverse labs for disease diagnosis, biomedical research, and vaccine development. Its multi-parameter function and large data storage enable efficient screening, immunoassays, and vaccine studies.

Microplate Reader LMPR-A16 | Microplate types : 96/48 -well plate | Photodetector : Silicon Photodiode
Microplate Reader LMPR-A16 | Dual Wavelength Analysis | 8-Channel Optical Scanning

Models of Microplate Reader

Labtron Microplate Readers have multiple wells (commonly 48, 96, 384, or 1536) that serve as small test tubes. These are used to detect biological, chemical, or physical events in samples within microtiter plates. Our advanced models offer a range of wavelengths, allowing users to customize the absorbance or fluorescence measurements according to specific requirements. With their high sensitivity and dynamic range, they are capable of detecting very low and high signals. They come with specialized software for controlling the reader, setting up protocols, and analyzing the collected data. To ensure that reagents and samples are well-mixed before measurement, our microplate readers include shaking or stirring functions.

Microplate Reader LMPR-A21

Microplate Reader LMPR-A21

  • Microplate types : 96/48 -well plate
  • Photodetector : Silicon Photodiode
  • Light source : 8V/50W Controlled tungsten halogen lamp or LED light
  • Wavelength range : 400nm to 800nm
Microplate Reader LMPR-B10

Microplate Reader LMPR-B10

  • Light Source : Xenon flash lamp (10⁹ flashes lifespan)
  • Wavelength Range : 200 to 1000 nm
  • Wavelength Selection : Grating monochromator
  • Wavelength Increment : 1 nm
Microplate Reader LMPR-A20

Microplate Reader LMPR-A20

  • Plate Type : 48/96-well plate
  • Wavelength Range : 400 to 850 nm
  • Standard Wavelength : 405, 450, 492, 630 nm
  • Additional filters : Filter wheel for up to 8 filters
Microplate Reader LMPR-A11
Microplate Reader LMPR-A11
  • Plate Type : 96-well Plate
  • Readout Range : 0.000 to 3.500Abs
  • Wavelength : 405, 450, 492, 630nm, Two more optional
  • Stability :
Microplate Reader LMPR-A17
Microplate Reader LMPR-A17
  • Microplate types : 96/48 -well plate
  • Photodetector : Silicon Photodiode
  • Light source : 8V/50W Controlled tungsten halogen lamp or LED light
  • Wavelength range : 400nm to 800nm
Microplate Reader LMPR-A10

Microplate Reader LMPR-A10

  • Plate Type : 96-well plate
  • Wavelength Range : 400 to 750 nm
  • Standard Wavelength : 405, 450, 492, 630 nm
  • Wavelength Accuracy :
Multi-Mode Microplate Reader LMMR-A10

Multi-Mode Microplate Reader LMMR-A10

  • Microplate Types : Supports 6 to 384 well plates; 96-well included
  • Light source : Xenon lamp
  • Temperature Control : RT +4 °C to 45 °C ± 0.5 °C at 37 °C
  • Dynamic Range : 0 to 4 OD range supported
Microplate Reader LMPR-A12

Microplate Reader LMPR-A12

  • Light Source : controller tungsten halogen lamp
  • Wavelength Range : 400 nm to 800 nm
  • Standard Filters : 405, 450, 492, 630 nm and 4 optional
  • Reading range : 0.000 to 4.000 Abs

Microplate Reader LMPR-A16 FAQ's
  • The Microplate Reader operates within a wavelength range of 400nm to 800nm, providing optimal performance for various assays. This broad range ensures compatibility with a wide spectrum of diagnostic and research applications. It allows precise detection across multiple assay types, including ELISA and enzyme activity studies. The extended wavelength range enhances flexibility in protocol design. It also supports accurate measurement of both high- and low-absorbance samples.

  • It can perform 12 different tests on a single plate simultaneously, making it suitable for high-throughput laboratories and enhancing productivity. This multi-test capability improves workflow efficiency and reduces processing time. It enables comparative analysis across different samples in a single run. The feature is particularly beneficial in clinical diagnostics, vaccine studies, and large-scale screening programs.

  • Yes, the device includes auto lamp adjustment and auto calibration features. These functionalities enhance system efficiency and accuracy while reducing maintenance time and operational costs. Automatic calibration ensures consistent assay performance across multiple runs. Auto lamp adjustment extends the lifespan of the optical system and maintains reliable measurements.

  • A Microplate Reader, commonly called as plate reader or plate spectrophotometer, is an analytical instrument that reads or detects the physical, chemical, and biological events of the analyte, within the wells of the plate. It has numerous tiny wells where the sample analyte is introduced for analysis.

  • A standard spectrophotometer measures the absorbance of one sample at a time. The sample is typically placed in a cuvette through which light is sent horizontally. An absorbance plate reader offers higher throughput and can measure the absorbance of samples in microplates (typically 96-well or even 384-well) by sending light through each well vertically.

  • Microplate-based measurements detect light signals produced by a sample, converted by a sample, or transmitted through a sample. In the plate reader, the signal is measured by a detector, usually a photomultiplier tube (PMT). PMTs convert photons into electricity that is then quantified by the microplate reader. The output of this process is numbers by which a sample is quantified.

  • Tungsten-halogen or xenon flash lamps are generally used. LEDs have also come into the picture in some modern readers.

  • The detection technology can be of 3 types- Monochromator based detection which provides flexibility, convenience, and spectral scanning; Filter based detection which enables rapid switch between different wavelengths; Hybrid detection which has dual technological advantage of both flexibility and sensitivity.

Post your question?

Our experts are here to help!

Microplate Reader:
Microplate Reader LMPR-A21, Microplate Reader LMPR-B10, Microplate Reader LMPR-A20, Microplate Reader LMPR-A11, Microplate Reader LMPR-A17, Microplate Reader LMPR-A10, Multi-Mode Microplate Reader LMMR-A10, Microplate Reader LMPR-A12, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.