Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Outer Crucible-Material Carbon structural steel
Outer Crucible-Diameter Of Upper Opening Φ100 ± 5 mm
Outer Crucible-Height 50 ± 5 mm
Outer Crucible-Diameter Of Bottom Φ56 ± 2 mm
Inner Crucible-Material Carbon structural steel
Inner Crucible-Diameter Of Upper Opening Φ64 ± 1 mm
Inner Crucible-Height 47 ± 1 mm
Inner Crucible-Diameter Of Bottom Φ38± 1 mm
Inner Crucible-Scale Line 12mm away from the rim of upper opening and 18mm away from the rim of upper opening
Gas Tube Φ0.8 ~ Φ1 mm
Flame 3 to 4 mm
Heater Heated by an electric furnace
Heating Power 1000W
Dimensions 410 x 360 x 240 mm
Power Consumption ≤ 1100 W
Power Supply AC 220 V ± 10 %, 50Hz
  • Adjustable heating power Electric current meter to display power Tiny desktop structure Easy to operate

Used to determine the flash point and fire point of lubricating oil and dark petroleum products

Models of Open Cup Flash Point Tester

Labtron Open Cup Flash Point Tester features adjustable heating power for precise control over temperature settings, with an electric current meter to display power consumption. These include menu prompts and guided input functions, simplifying the setup process for users. Their electric ignition mode ensures a reliable start-up for smooth operation. They have a detachable ionization ring for easy cleaning, maintenance, and longevity. Our open cup flash point tester has a barometric correction for temperature calibration, ensuring accurate readings and accounting for atmospheric pressure variations.

Cleveland Open Cup Flash Point Tester LOFP-A11

Cleveland Open Cup Flash Point Tester LOFP-A11

  • Temperature Measurement Range : Room Temperature to 400℃
  • Repeatability : Flash Point ≤150℃: ±2℃ Flash Point ≥150℃: ±3℃
  • Resolution : 0.1℃
  • Precision : 0.5%
Automatic COC Flash & Fire Point Tester LOFP-B10

Automatic COC Flash & Fire Point Tester LOFP-B10

  • Ambient Temperature : 10 ℃ ~ 40 ℃
  • Relative Humidity : ≤ 85 %
  • Temperature Measurement- Full Scale : Ambient temperature to ~ 400 ℃
  • Temperature Measurement- Repeatability : ≤ 4 ℃
Automatic COC Flash Point & Fire Point Tester LOFP-B11

Automatic COC Flash Point & Fire Point Tester LOFP-B11

  • Measuring Range : 79 to 370℃ (175 to 698℉)
  • Resolution : 0.1℃
  • Repeatability : ≤ 6℃
  • Reproducibility : ≤ 8℃
Automatic Cleveland Open Cup Flash Point Tester LOFP-A12
Automatic Cleveland Open Cup Flash Point Tester LOFP-A12
  • Ambient Temperature : 10 ℃ to 40 °C
  • Relative Humidity : ≤ 80 %
  • Temperature Measurement- Full Scale : Ambient temperature to 300 °C
  • Temperature Measurement- Repeatability : ≤ 8 °C

Open Cup Flash Point Tester LOFP-A10 FAQ's
  • The Open Cup Flash Point Tester LOFP-A10 uses an electric ignition system, which provides consistent and safe flame application during testing. This method reduces the variability and risk associated with manual ignition. A detachable ionization ring is used to stabilize and direct the flame. Users must ensure that the ignitor and flame ring are clean and properly positioned before each test.

  • The Open Cup Flash Point Tester LOFP-A10 can be used to determine both the flash point and the fire point of a sample. The flash point is the temperature at which vapors ignite briefly, while the fire point is when the sample sustains burning for at least five seconds. Both are measured in sequence as the temperature continues to rise. This dual capability provides more complete flammability data for oils and fuels.

  • Labtron Open Cup Flash Point Tester LOFP-A10 is not suitable for fuels with very low flash points such as gasoline or alcohol. It is specifically designed for the Cleveland Open Cup method, intended for materials with flash points above approximately 79°C. Using low-flash point samples may lead to inaccurate results and pose safety risks. For such applications, a closed cup tester like the Pensky-Martens type is more appropriate.

  • Our Open Cup Flash Point Tester LOFP-A10 is a manually operated device and does not feature automatic flash point detection. The operator is required to monitor the temperature and visually observe the flame to determine both flash and fire points. It includes electric ignition and adjustable heating control for user convenience. This design makes it ideal for labs that prefer hands-on control and cost-effective testing.

  • Labtron Open Cup Flash Point Tester LOFP-A10 may fail to detect a flash point if certain conditions are not met. First, ensure the correct sample volume is used and that the test flame is functioning properly. Check if the heating rate aligns with the recommended standard, as heating too quickly or too slowly can affect the results. Also, verify that the sample is appropriate for open cup testing and is free from contamination. Cleaning the test cup and inspecting the ignition system often helps resolve the issue.

Post your question?

Our experts are here to help!

Open Cup Flash Point Tester:
Cleveland Open Cup Flash Point Tester LOFP-A11, Automatic COC Flash & Fire Point Tester LOFP-B10, Automatic COC Flash Point & Fire Point Tester LOFP-B11, Automatic Cleveland Open Cup Flash Point Tester LOFP-A12, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.