Pilot Standard Freeze Dryer LPFD-E12

Pilot Standard Freeze Dryer LPFD-E12

Pilot Standard Freeze Dryer LPFD-E12 has an ice condenser capacity of 12 kg. Its refrigeration system consists of dual compressors that help to reach ultra-low temperatures faster and more stably. This freeze dryer has a double-chamber stainless steel system, which can be customized with Teflon anti-corrosion treatment. The vacuum pump has a double anti-oil return device. Our freeze dryer is suitable for mid-to-large-scale pharmaceutical manufacturing and clinical batch production.

Request Quote
Ice Condenser Capacity 12 kg
Condenser Temperature - 86℃
Freeze Drying Area 1.008 m2
Cold Trap Volume 18 L
Chamber Type Double
Max Number of Shelves 6 + 1
Shelf Temperature - 60℃ to + 80℃
Shelf Size 340 × 500 mm
Shelf Spacing 100 (adjustable)
Shelf Heating and Cooling Method Thermal conducting silicone oil medium
Number of Penicillin Bottles (Փ 16 mm) 1880
External Valve 18 (customizable)
Capping Mode Hydraulic system capping device/no capping
Sterilization Method H2O2/ Steam sterilization
Remote Control and Alarm Supports 2G/4G/GSM/Wi-Fi
Inert Gas Filling Sufficient amount and time for the program to run itself (optional)
Pipeline Diameter Փ 89 mm
Vacuum Sensor Type Pirani vacuum sensor/capacitive vacuum sensor
Terminal Judgment Function Pressure test/pressure contrast method
Power 6500 W
Power Supply 380 V, 50 Hz
Dimensions 1030 × 700 × 1630 mm
Packaging Dimensions 1200 × 840 × 1830 mm
Net Weight 500 kg
Gross Weight 550 kg
  • Automatic and manual control

  • High-condensation efficiency

  • Cascade Refrigeration method

  • Double anti-oil return device

  • Two-stage rotary vane pump

Our Pilot Standard Freeze Dryer LPFD-E12 is used for process development and optimization before full-scale production. It helps to simulate commercial freeze-drying conditions for pharmaceuticals, biologics, or food to ensure scalability and consistency.

Vacuum pump × 1

Hydraulic gland device × 1

Sample temperature probes × 6

Sample temperature probe

Sample tray

  • Eutectic point testing system

  • Lyophilization curve analysis and recording software

  • Pressure rise test system

Models of Pilot Freeze Dryer

Labtron Pilot Freeze Dryer is specialized to remove moisture from material while preserving its structure and biochemical properties. They are equipped with condenser working at temperature ranging from -70℃ to -80℃. Their automatic defrost cycles reduce manual intervention and streamline maintenance procedures. They utilize vacuum technology to preserve quality of sensitive materials during drying process. Our Pilot Freeze Dryer is efficient for pharmaceuticals, food storage, and research applications.

Pilot Standard Freeze Dryer LPFD-B13

Pilot Standard Freeze Dryer LPFD-B13

  • Drying Area : 0.82 m²
  • Shelf Temperature : -50 to +60 ℃
  • Shelf Temperature Limit : Less than or Equal to -55℃ (no-load)
  • Shelf Temperature Uniformity : ±1℃ (under stabilized state)
Pilot Top Press Freeze Dryer LPFD-C12

Pilot Top Press Freeze Dryer LPFD-C12

  • Condenser Temperature : - 80℃
  • Condenser Capacity : 40 kg/ 24 h
  • Condenser Volume : 90 L
  • Freeze Drying Area : 2 m2
Pilot Standard Freeze Dryer LPFD-B10

Pilot Standard Freeze Dryer LPFD-B10

  • Condenser Temperature : -80°C
  • Condenser Capacity : 6 kg / 24 h
  • Freeze Drying Area : 0.4 m2
  • Bulk Capacity : 4 L
Pilot Top Press Freeze Dryer LPFD-A12
Pilot Top Press Freeze Dryer LPFD-A12
  • Drying Area : 0.2 m²
  • Shelf Temperature : -50 to +60 ℃
  • Shelf Temperature Limit : Less than or Equal to -55℃ (no-load)
  • Shelf Temperature Uniformity : ±1℃ (under stabilized state)
Pilot Top Press Freeze Dryer LPFD-D12
Pilot Top Press Freeze Dryer LPFD-D12
  • Condenser Temperature : ≤ -75℃
  • Condenser Capacity : > 10kg
  • Freeze Drying Area : 0.5 m²
  • Bulk Capacity : 5L
Pilot Standard Freeze Dryer LPFD-C10

Pilot Standard Freeze Dryer LPFD-C10

  • Condenser Temperature : ≤-75℃
  • Condenser Capacity : ≥10kg/24h
  • Freeze Drying Area : 0.5 m²
  • Bulk Capacity : 8L/s
Pilot Standard Freeze Dryer LPFD-B14

Pilot Standard Freeze Dryer LPFD-B14

  • Drying Area : 1 m²
  • Shelf Temperature : -50 to +60 ℃
  • Shelf Temperature Limit : Less than or Equal to -55℃ (no-load)
  • Shelf Temperature Uniformity : ±1℃ (under stabilized state)
Pilot Standard Freeze Dryer LPFD-F22

Pilot Standard Freeze Dryer LPFD-F22

  • Equipment Appearance and Structure : Vertical unit (cylindrical material chamber)
  • Drying Area : 0.4 m²
  • Shelf Temperature : -45 to +50 ℃
  • Shelf Temperature Limit : Less than or Equal to -55℃ (no-load)

Pilot Standard Freeze Dryer LPFD-E12 FAQ's
  • Labtron’s Pilot Standard Freeze Dryer uses a two-stage rotary vane pump as standard. User can select or use any other pump with a pump rate of 9 m3/h to 62 m3/h and for which the ultimate vacuum can reach 2 × 10-3 to 5 × 10-3 mbar. This allows versatility for the usage of our freeze dryer.

  • Pilot-scale freeze dryers are larger, more robust, and equipped with features that simulate industrial drying environments. They support higher sample loads, multiple shelf configurations, and advanced monitoring systems. Lab-scale dryers are mainly for R&D and experimentation, while pilot-scale units assist in transitioning to commercial production. The latter also supports limited GMP-compliant manufacturing.

  • Yes, pilot-scale freeze dryers are often used for small-batch or clinical-stage production. They are suitable for producing trial batches of pharmaceuticals, vaccines, or biologics under real processing conditions. With the right configuration, they can meet regulatory and quality standards. This makes them valuable for pre-market releases or contract manufacturing.

  • Our Pilot Standard Freeze Dryer is designed to handle a wide variety of materials. These include pharmaceutical formulations, sensitive biological, food samples, vaccines, and herbal or plant-based extracts. It is also used in diagnostics to preserve reagents or enzymes. Its versatility supports use across pharma, biotech, and food industries.

  • . Labtron’s Pilot Standard Freeze Dryer typically uses a Pirani and capacitive vacuum sensors for precise pressure measurement. These sensors help control critical drying stages by monitoring vacuum levels in real-time. The combination of both ensures accuracy across a wide pressure range. This results in more consistent drying cycles and better product quality.

Post your question?

Our experts are here to help!

Pilot Freeze Dryer:
Pilot Standard Freeze Dryer LPFD-B13, Pilot Top Press Freeze Dryer LPFD-C12, Pilot Standard Freeze Dryer LPFD-B10, Pilot Top Press Freeze Dryer LPFD-A12, Pilot Top Press Freeze Dryer LPFD-D12, Pilot Standard Freeze Dryer LPFD-C10, Pilot Standard Freeze Dryer LPFD-B14, Pilot Standard Freeze Dryer LPFD-F22, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.