Pilot Standard Freeze Dryer LPFD-F11 features a condenser temperature of -35°C, enabling reliable freeze-drying of sensitive samples. It supports multiple vial sizes, offering flexibility for varied research needs. The low noise output makes it suitable for quiet lab settings, supporting focused work and reducing potential disruptions. Our freeze dryer is widely used in academic and research applications requiring controlled conditions and consistent results.

Pilot standard freeze dryer LPFD-F11 -1
Pilot standard freeze dryer LPFD-F11-2
Pilot standard freeze dryer LPFD-F11-3
Request Quote
Condenser Temperature Less than or equal to -35°C
Layer Temperature Accuracy Less than or equal to ±1°C
Shelf Temperature -25°C to +80°C
Minimum Layer Temperature Less than or equal to -25°C
System Ultimate Vacuum Degree Less than or equal to 5 Pa
Layer Cooling Rate Less than or equal to 120 min (+20°C to -25°C)
Cold Trap Cooling Rate 20°C to -35°C within 20 min
Layer Heating Rate Less than or equal to 120 min (-25°C to +20°C)
Condenser Capacity Less than or equal to 6 kg
Bulk Capacity 4 to 6 kg/batch
Liquid Product Capacity About 6 L (thickness 10mm)
Vial Capacity Φ 12 mm 2400 vials
Vial Capacity Φ 16 mm 1350 vials
Vial Capacity Φ 22 mm 715 vials
Layer Spacing 45 mm
Refrigerant R404
Noise Level Less than or equal to 62 dB
Defrosting Method Electric heating defrosting
Freeze Drying Area 0.34 m²
Layer Dimension (L×H) 210 mm × 435 mm
Power Consumption 1500 W
Power Supply Single phase 220V
Packaging Dimension (L×W×H) 630 × 840 × 1260 mm
Dimension (L×W×H) 500 × 640 × 900 mm
Packaging Weight 139 kg
Weight 84 kg
  • Vacuum gauge pressure tracking

  • Real-time status display

  • Stainless steel drying chamber

  • Durable cold trap construction

  • Efficient shelf heat transfer

Pilot Standard Freeze Dryer LPFD-F11 facilitates low-temperature drying of temperature-sensitive samples without compromising their integrity. It is commonly used in pharmaceutical development labs, research facilities, and academic institutions working with biological materials, extracts, or chemical formulations.

Models of Pilot Freeze Dryer

Labtron Pilot Freeze Dryer is specialized to remove moisture from material while preserving its structure and biochemical properties. They are equipped with condenser working at temperature ranging from -70℃ to -80℃. Their automatic defrost cycles reduce manual intervention and streamline maintenance procedures. They utilize vacuum technology to preserve quality of sensitive materials during drying process. Our Pilot Freeze Dryer is efficient for pharmaceuticals, food storage, and research applications.

Pilot Standard Freeze Dryer LPFD-C10

Pilot Standard Freeze Dryer LPFD-C10

  • Condenser Temperature : ≤-75℃
  • Condenser Capacity : ≥10kg/24h
  • Freeze Drying Area : 0.5 m²
  • Bulk Capacity : 8L/s
Pilot Standard Freeze Dryer LPFD-B15

Pilot Standard Freeze Dryer LPFD-B15

  • Drying Area : 1.15 m²
  • Shelf Temperature : -50 to +60 ℃
  • Shelf Temperature Limit : Less than or Equal to -55℃ (no-load)
  • Shelf Temperature Uniformity : ±1℃ (under stabilized state)
Pilot Top Press Freeze Dryer LPFD-A14

Pilot Top Press Freeze Dryer LPFD-A14

  • Drying Area : 0.4 m²
  • Shelf Temperature : -50 to +60 ℃
  • Shelf Temperature Limit : Less than or Equal to -55℃ (no-load)
  • Shelf Temperature Uniformity : ±1℃ (under stabilized state)
Pilot Top Press Freeze Dryer LPFD-C11
Pilot Top Press Freeze Dryer LPFD-C11
  • Condenser Temperature : - 70 °C
  • Condenser Capacity : 10 kg / 24 h
  • Freeze Drying Area : 0.5 m²
  • Bulk Capacity : 5 L
Pilot Standard Freeze Dryer LPFD-E10
Pilot Standard Freeze Dryer LPFD-E10
  • Ice Condenser Capacity : 4 kg
  • Condenser Temperature : - 86℃
  • Freeze Drying Area : 0.256 m2
  • Cold Trap Volume : 9 L
Pilot Standard Freeze Dryer LPFD-F12

Pilot Standard Freeze Dryer LPFD-F12

  • Condenser Temperature : Less than or equal to -35°C
  • Layer Temperature Accuracy : Less than or equal to ±1°C
  • Shelf Temperature : -25°C to +80°C
  • Minimum Layer Temperature : Less than or equal to -25°C
Pilot Standard Freeze Dryer LPFD-F21

Pilot Standard Freeze Dryer LPFD-F21

  • Equipment Appearance and Structure : Vertical unit (cylindrical material chamber)
  • Drying Area : 0.3 m²
  • Shelf Temperature : -45 to +50 ℃
  • Shelf Temperature Limit : Less than or Equal to -55℃ (no-load)
Pilot Standard Freeze Dryer LPFD-A10

Pilot Standard Freeze Dryer LPFD-A10

  • Condenser Temperature : - 70 °C
  • Condenser Capacity : 3 kg / 24 h
  • Freeze Drying Area : 0.2 m²
  • Bulk Capacity : 2 L

Pilot Standard Freeze Dryer LPFD-F11 FAQ's
  • Our Pilot Standard Freeze Dryer is built with lab-scale dimensions that help maintain workspace flow in smaller facilities. The upright structure saves surface area while still offering ample drying volume for test runs. Casters offer easy mobility when labs need to reorganize or relocate systems. Its front-loaded operation simplifies access without needing extra clearance. This makes it well-suited to busy, modular lab stations. Controls are all panel-mounted, keeping operations within easy reach. The unit passes through standard lab doorways without disassembly. Pilot Standard Freeze Dryer adapts to dynamic environments without causing space constraints or setup conflicts.

  • The Pilot Standard Freeze Dryer helps meet short timelines by reducing preparation and transition periods between drying stages. Our unit features programmable shelf control that supports rapid ramping to target temperatures. Internal system logic regulates each stage to minimize downtime between batches. Fast response times let users maintain a consistent pace in sequential sample testing. Cycle settings can be saved and reloaded, reducing setup delays. Its components stabilize quickly after start-up. This unit provides an advantage in pilot studies with submission deadlines. Pilot Standard Freeze Dryer suits labs managing multiple concurrent research windows with minimal lag.

  • Labtron developed the Pilot Standard Freeze Dryer with a wide thermal range to manage samples that shift in viscosity with temperature. The system maintains even layer exposure, supporting uniform transitions for low-viscosity fluids. Its shelf-to-shelf heat distribution avoids cold spots that could alter liquid behavior during drying. Protective cutoff settings maintain shelf temperatures within safe thresholds. Tray configurations allow flexibility for flask and vial placement to prevent surface disturbances. Cycle programming includes gradual shifts to avoid abrupt changes. The setup is ideal for labs formulating unstable liquids. Pilot Standard Freeze Dryer preserves sample attributes across sensitive phases of development.

  • The Pilot Standard Freeze Dryer supports broad usage through adaptable chamber space and recipe programming. Our platform allows diverse product types—plant extracts, diagnostic kits, and fermentation residues—to be processed with custom settings. Temperature and vacuum profiles can be adjusted to fit the chemical behavior of different materials. Its digital memory saves and reuses process maps for dissimilar experiments. Each tray accommodates various sample geometries without sacrificing airflow. Workflow transitions are simplified for multi-department research setups. This is especially helpful in universities and shared commercial labs. Pilot Standard Freeze Dryer supports flexible scheduling across mixed-method programs.

  • The Pilot Standard Freeze Dryer promotes laboratory safety through structural and operational safeguards. Our system includes lid interlocks that prevent access during active vacuum cycles. High-limit cutoffs automatically halt heating or cooling to prevent material degradation. An enclosed compressor section keeps external surfaces cool. Front-facing alert indicators provide quick visibility on system status. Programmable access codes secure operational settings in multi-user labs. All thermal connections are reinforced to prevent leakage and condensation risks. Sound insulation ensures acoustic safety around sensitive lab work. Pilot Standard Freeze Dryer meets safety priorities without compromising function or workflow.

  • The Pilot Standard Freeze Dryer enables mid-range output levels suited for labs preparing pre-commercial testing. Our unit holds a broad range of vials and containers, supporting mid-size batch requirements in test production. It can replicate conditions found in large systems without needing factory-scale utilities. Chamber capacity allows mock runs for regulatory sampling. Batch records can be exported for compliance tracking. This allows researchers to fine-tune methods before full production. Multiple shelf layers support flexible sample arrangement. Pilot Standard Freeze Dryer helps researchers transition from lab data to scale-up protocols within the same system.

Post your question?

Our experts are here to help!

Pilot Freeze Dryer:
Pilot Standard Freeze Dryer LPFD-C10, Pilot Standard Freeze Dryer LPFD-B15, Pilot Top Press Freeze Dryer LPFD-A14, Pilot Top Press Freeze Dryer LPFD-C11, Pilot Standard Freeze Dryer LPFD-E10, Pilot Standard Freeze Dryer LPFD-F12, Pilot Standard Freeze Dryer LPFD-F21, Pilot Standard Freeze Dryer LPFD-A10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.