Request A Quote
Pilot Standard Freeze Dryer LPFD-F10

Pilot Standard Freeze Dryer LPFD-F10

Pilot Standard Freeze Dryer LPFD-F10 features a condenser temperature of -35°C, ensuring efficient freeze-drying for sensitive materials. The built-in vacuum gauge enables accurate pressure tracking to preserve product structure during sublimation. Offers a real-time display system that provides live process updates, allowing timely adjustments. Our freeze dryer is widely used in food testing and research labs handling small-scale tasks. 

Pilot Standard Freeze Dryer LPFD-F10 1
Pilot Standard Freeze Dryer LPFD-F10 2
Pilot Standard Freeze Dryer LPFD-F10 3
Request Quote
Condenser Temperature Less than or equal to -35°C
Layer Temperature Accuracy Less than or equal to ±1°C
Shelf Temperature -25°C to +80°C
Minimum Layer Temperature Less than or equal to -25°C
System Ultimate Vacuum Degree Less than or equal to 5 Pa
Layer Cooling Rate Less than or equal to 120 min (+20°C to -25°C)
Cold Trap Cooling Rate 20°C to -35°C within 20 min
Layer Heating Rate Less than or equal to 120 min (-25°C to +20°C)
Condenser Capacity Less than or equal to 3 kg
Bulk Capacity 2 kg/batch
Liquid Product Capacity About 2L (thickness 10mm)
Vial Capacity Φ 12 mm 710 vials
Vial Capacity Φ 16 mm 405 vials
Vial Capacity Φ 22 mm 210 vials
Layer Spacing 43 mm
Refrigerant R404
Noise Level Less than or equal to 62 dB
Defrosting Method Electric heating defrosting
Freeze Drying Area 0.1 m²
Layer Dimension (L×H) 150 mm × 280 mm
Power Consumption 1100 W
Power Supply Single phase 220V
Packaging Dimension (L×W×H) 570 × 680 × 1170 mm
Dimension (L×W×H) 450 × 500 × 825 mm
Packaging Weight 113 kg
Weight 73 kg
  • Supports multiple vial sizes

  • Single-phase power compatibility

  • Low operational noise output

  • Uniform temperature layer control

  • Anti-leak integrated structure

Pilot Standard Freeze Dryer LPFD-F10 gently removes moisture from samples using low-temperature sublimation, preserving structure and composition. It is widely used across research laboratories, pharmaceutical development, food quality testing, and advanced biotechnology applications.

Models of Pilot Freeze Dryer

Labtron Pilot Freeze Dryer is specialized to remove moisture from material while preserving its structure and biochemical properties. They are equipped with condenser working at temperature ranging from -70℃ to -80℃. Their automatic defrost cycles reduce manual intervention and streamline maintenance procedures. They utilize vacuum technology to preserve quality of sensitive materials during drying process. Our Pilot Freeze Dryer is efficient for pharmaceuticals, food storage, and research applications.

Pilot Top Press Freeze Dryer LPFD-D11

Pilot Top Press Freeze Dryer LPFD-D11

  • Condenser Temperature : - 70 °C
  • Condenser Capacity : 15 kg / 24 h
  • Freeze Drying Area : 1.15 m²
  • Bulk Capacity : 11 L
Pilot Standard Freeze Dryer LPFD-F11

Pilot Standard Freeze Dryer LPFD-F11

  • Condenser Temperature : Less than or equal to -35°C
  • Layer Temperature Accuracy : Less than or equal to ±1°C
  • Shelf Temperature : -25°C to +80°C
  • Minimum Layer Temperature : Less than or equal to -25°C
Pilot Top Press Freeze Dryer LPFD-A11

Pilot Top Press Freeze Dryer LPFD-A11

  • Condenser Temperature : - 70 °C
  • Condenser Capacity : 3 kg / 24 h
  • Freeze Drying Area : 0.1 m²
  • Bulk Capacity : 1 L
Pilot Standard Freeze Dryer LPFD-G11
Pilot Standard Freeze Dryer LPFD-G11
  • Drying Area : 0.24 ㎡
  • Shelf Temperature : -45 to +50 ℃
  • Shelf Temperature Limit : Less than or Equal to -55℃ (no-load)
  • Shelf Temperature Uniformity : ±1℃ (under stabilized state)
Pilot Standard Freeze Dryer LPFD-F12
Pilot Standard Freeze Dryer LPFD-F12
  • Condenser Temperature : Less than or equal to -35°C
  • Layer Temperature Accuracy : Less than or equal to ±1°C
  • Shelf Temperature : -25°C to +80°C
  • Minimum Layer Temperature : Less than or equal to -25°C
Pilot Standard Freeze Dryer LPFD-F14

Pilot Standard Freeze Dryer LPFD-F14

  • Condenser Temperature : Less than or equal to -60°C
  • Layer Temperature Accuracy : Less than or equal to ±1°C
  • Shelf Temperature : -40°C to +80°C
  • Minimum Layer Temperature : Less than or equal to -40°C
Pilot Top Press Freeze Dryer LPFD-A14

Pilot Top Press Freeze Dryer LPFD-A14

  • Drying Area : 0.4 m²
  • Shelf Temperature : -50 to +60 ℃
  • Shelf Temperature Limit : Less than or Equal to -55℃ (no-load)
  • Shelf Temperature Uniformity : ±1℃ (under stabilized state)
Pilot Top Press Freeze Dryer LPFD-D12

Pilot Top Press Freeze Dryer LPFD-D12

  • Condenser Temperature : ≤ -75℃
  • Condenser Capacity : > 10kg
  • Freeze Drying Area : 0.5 m²
  • Bulk Capacity : 5L

Pilot Standard Freeze Dryer LPFD-F10 FAQ's
  • Our Pilot Standard Freeze Dryer uses a low-temperature sublimation method that preserves structural and chemical properties during drying. It's ideal for temperature-sensitive organic materials and biological samples. This feature ensures materials retain their core characteristics throughout the process. The drying method reduces stress on delicate compounds. Users in biopharmaceuticals often prefer this for fragile ingredients. The unit minimizes product collapse or shrinkage. Its performance is consistent across small-batch applications. A well-regulated pressure profile also helps stabilize molecular structures during the transition phase. The chamber environment is precisely tuned to support consistent results across batches with varying composition.

  • The Pilot Standard Freeze Dryer fits perfectly into academic settings due to its manageable size and ease of operation. Its data recording functionality allows documentation for lab reports and research. The equipment is compact enough to fit in tight lab spaces. Maintenance requirements are minimal. Training students is straightforward due to the clear control interface. Teachers benefit from the system’s visibility of cycle parameters. It serves well in practical demonstrations and research validation. Additionally, its safety features help instructors maintain secure learning environments during hands-on sessions. Laboratory coordinators appreciate its low learning curve when used in multi-user classrooms.

  • Labtron designed the Pilot Standard Freeze Dryer to accommodate fruits, herbs, extracts, and biological specimens. Each tray supports uniform drying regardless of sample shape or texture. The device supports mixed product runs within a single batch. Its internal layout ensures airflow reaches all layers. This setup minimizes cycle discrepancies. Researchers can optimize cycles with built-in control flexibility. Suitable for low-moisture and high-density items. The chamber’s spacing and programmable settings allow cross-discipline labs to process diverse materials without equipment adjustments. It also prevents contamination crossover between different sample types during concurrent runs.

  • Its design supports single-phase 220V, which suits many global power standards. This allows for easy export without needing external converters. It ships units with plug types matching the destination region. Clients can request custom power configurations during procurement. The product manual lists compatible voltage ranges. It simplifies procurement for international buyers. Export-ready design is part of its versatility. The internal circuitry is stress-tested for voltage fluctuations to ensure long-term stability across regions. This makes it a reliable choice for overseas labs with inconsistent power conditions.

  • Our freeze dryer is shipped with reinforced protective packaging designed to prevent vibration damage. Custom foam linings and brackets are used for internal stability. The crate size allows for forklift compatibility. All export packaging complies with ISPM 15 standards. A packaging list and installation guide are included. This ensures all units pass drop and impact checks. Additional corner buffers and water-resistant wraps are included to protect the unit during unpredictable shipping conditions. Transit indicators are also attached to notify handlers of any tilting or mishandling during logistics.

  • Labtron built this product with a compressor system known for reduced vibration and minimal operational sound. This makes it ideal for labs with noise-sensitive instrumentation or working areas. The cooling and vacuum units are enclosed for acoustic insulation. The overall decibel level supports a quiet workspace. Some labs even place it adjacent to workbenches. Unlike industrial systems, it's made for quieter zones. It’s engineered for peace in shared labs. Lab technicians often report uninterrupted workflow even when placed near precision sound monitoring setups. The low-sound profile contributes to a more focused work atmosphere in collaborative research environments.

Post your question?

Our experts are here to help!

Pilot Freeze Dryer:
Pilot Top Press Freeze Dryer LPFD-D11, Pilot Standard Freeze Dryer LPFD-F11, Pilot Top Press Freeze Dryer LPFD-A11, Pilot Standard Freeze Dryer LPFD-G11, Pilot Standard Freeze Dryer LPFD-F12, Pilot Standard Freeze Dryer LPFD-F14, Pilot Top Press Freeze Dryer LPFD-A14, Pilot Top Press Freeze Dryer LPFD-D12, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.