| Condenser Temperature | Less than or equal to -35°C |
| Layer Temperature Accuracy | Less than or equal to ±1°C |
| Shelf Temperature | -35°C to +80°C |
| Minimum Layer Temperature | Less than or equal to -25°C |
| System Ultimate Vacuum Degree | Less than or equal to 5 Pa |
| Layer Cooling Rate | Less than or equal to 120 min (+20°C to -25°C) |
| Cold Trap Cooling Rate | 20°C to -35°C within 20 min |
| Layer Heating Rate | Less than or equal to 120 min (-25°C to +20°C) |
| Condenser Capacity | Less than or equal to 12 kg |
| Bulk Capacity | 10 to 12 kg/batch |
| Liquid Product Capacity | About 12 L (thickness 10mm) |
| Vial Capacity Φ 12 mm | 6510 vials |
| Vial Capacity Φ 16 mm | 3662 vials |
| Vial Capacity Φ 22 mm | 1937 vials |
| Layer Spacing | 38 mm |
| Refrigerant | R404 |
| Noise Level | Less than or equal to 62 dB |
| Defrosting Method | Electric heating defrosting |
| Freeze Drying Area | 0.92 m² |
| Layer Dimension (L×H) | 275 mm × 445 mm |
| Power Consumption | 2500 W |
| Power Supply | Single phase 220V |
| Packaging Dimension (L×W×H) | 820 × 800 × 1540 mm |
| Dimension (L×W×H) | 680 × 640 × 1180 mm |
| Packaging Weight | 203 kg |
| Weight | 130 kg |
Quick-start freeze mode
Compact vertical layout
Rapid condenser recovery
Modular tray design
Touchscreen cycle access
Pilot Standard Freeze Dryer LPFD-F13 removes moisture from temperature-sensitive materials without damaging their structure or composition. It is used in laboratory research units, pharmaceutical development labs, food testing facilities, and small-scale production setups.
Download catalog for
Pilot Standard Freeze Dryer LPFD-F13 Catalog
Available Range :
Pilot Top Press Freeze Dryer LPFD-C11 : - 70 °C Pilot Top Press Freeze Dryer LPFD-C12 : - 80℃ Pilot Standard Freeze Dryer LPFD-E10 : - 86℃ Pilot Standard Freeze Dryer LPFD-B10 : -80°C Pilot Standard Freeze Dryer LPFD-F10 : Less than or equal to -35°C Pilot Standard Freeze Dryer LPFD-F14 : Less than or equal to -60°C Pilot Top Press Freeze Dryer LPFD-D12 : ≤ -75℃ Pilot Standard Freeze Dryer LPFD-C10 : ≤-75℃Labtron Pilot Freeze Dryer is specialized to remove moisture from material while preserving its structure and biochemical properties. They are equipped with condenser working at temperature ranging from -70℃ to -80℃. Their automatic defrost cycles reduce manual intervention and streamline maintenance procedures. They utilize vacuum technology to preserve quality of sensitive materials during drying process. Our Pilot Freeze Dryer is efficient for pharmaceuticals, food storage, and research applications.








Our Pilot Standard Freeze Dryer supports extended cycle durations without compromising sample quality due to its consistent thermal distribution across all trays. This allows operators to handle sensitive substances such as botanicals or nutraceutical blends without worrying about inconsistencies. The equipment’s structure supports uninterrupted drying, minimizing thermal fluctuation over long periods. Carefully balanced insulation helps reduce environmental interference during prolonged operations. It’s also capable of maintaining set parameters even with complex product compositions. The Pilot Standard Freeze Dryer ensures batch reliability across multiple formats. Its design maintains uniformity even with varying moisture levels or material types. The unit preserves critical characteristics throughout the drying cycle without risking deterioration.
The Pilot Standard Freeze Dryer incorporates critical safeguards designed for consistent laboratory operation. Built-in over-temperature protection prevents system stress during prolonged runs, reducing the risk of component fatigue. Its architecture also includes stable power control to avoid voltage-related disruptions. The freeze dryer’s chamber has pressure-mitigating mechanisms that help preserve vacuum stability over extended use. It’s been engineered with attention to thermal resilience, preventing overheating during repeated use. Our Pilot Standard Freeze Dryer also features programmed stop sequences to avoid shock freezing. These ensure both user safety and product integrity in high-frequency applications. Its design reflects the practical needs of lab workflows that demand reliability and control.
The Pilot Standard Freeze Dryer supports gentle drying conditions tailored for heat-sensitive substances like enzymes, amino acids, or peptides. Its controlled environment helps reduce degradation risk during drying, especially in compounds prone to volatility. The layered system ensures low-temperature handling with minimal physical stress. With stable chamber insulation, the product stays protected against temperature variation that could affect molecular integrity. The Pilot Standard Freeze Dryer is trusted for bio-research settings requiring minimal biochemical alteration. Its architecture favors molecular preservation while maintaining drying efficacy. Our freeze dryer gives researchers a reliable platform to prepare delicate samples. It's ideal when outcome fidelity is crucial to experimental validity.
Labtron Pilot Standard Freeze Dryer accommodates multiple texture formats simultaneously without cross-contamination or quality inconsistency. The uniform layer spacing and heating response allow for drying items with different densities, like gels, slurries, or fibrous materials. Its chamber structure supports parallel processing for mixed applications. This is especially useful in test batches where textures vary across samples. The freeze dryer stabilizes internal parameters for each shelf, ensuring balanced drying regardless of material composition. Our Pilot Standard Freeze Dryer performs well even when processing organic blends with diverse moisture content. It offers a structured approach for simultaneous freeze-drying research. Ideal for R&D centers handling sample variations in one go.
The Pilot Standard Freeze Dryer’s design includes smooth interior linings that simplify cleaning between cycles. Its open-access structure enables thorough wipe-downs without disassembling complex parts. The freeze dryer’s drain system clears remaining residues post-defrost, helping maintain hygiene. Cleaning downtime is reduced through smart chamber layout and accessible trap areas. The Pilot Standard Freeze Dryer promotes safe sample transitions without buildup risks. Our unit’s exterior and cold trap resist material adherence that typically complicates cleanup. This makes it suitable for labs running frequent or rotating tests. It’s built for real-world lab routines that value quick resets and cross-contamination control.
Pilot Standard Freeze Dryer combines powerful freeze drying capability with a compact footprint that fits into tighter lab benches. Despite its functional depth, it doesn’t require extensive rearrangement of existing setups. The machine’s vertical build reduces lateral occupation, helping conserve bench real estate. It allows placement in multi-instrument rooms without spatial conflicts. The Pilot Standard Freeze Dryer supports robust performance in confined environments. We designed the system to accommodate high-function usage with modest space. Our unit’s plug-in configuration further simplifies lab integration. Its size makes it a practical choice for labs operating under tight spatial constraints.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608