Falling Weight Impact Tester TFWT-A11 operates at a controlled test temperature of 23 ℃ ±2℃ with sample lengths up to 152.4 mm. Utilizing the free-fall impact testing principle, it delivers precise and reliable results. The tester features an automated, computer-controlled system for easy parameter configuration. Provide automatic adjustment of lifting height and impact weight to meet the specific requirements of each test. Designed in compliance with industry standards, this impact tester ensures optimal performance and accuracy for testing various materials.
Request Quote
Maximum Sample Length 6 inches (152.4mm)
Test Temperature 23 ℃ ± 2 ℃
Sample Size Range 16 mm to 152 mm
Anvil Size 13 mm steel Plate
Hammer 01 Size Φ50.8mm
Hammer 02 Size Φ152.4mm
Hammer 01 Weight 9.1 Kg
Hammer 02 Weight 34 Kg
Hammer 01 Impact Height 100mm to 3350mm
Hammer 02 Impact Height 100mm to 2130mm
Hammer 01 Impact Energy 8.9J to 298.7J
Hammer 02 Impact Energy 33.3J to 709.7J
Power 4 KW
Dimension (L × W × H) 1000 × 1150 × 4500 mm
Weight 2200 Kg
  • Includes anti-second impact device
  • Base and guide rails for vertical alignment
  • Features safety protection devices
  • Electric lifting mechanism
  • Two hammers available
Our Falling Weight Impact Tester is perfect for manufacturers and quality control labs to assess the durability and impact resistance of rigid materials such as PVC pipes, conduits, and fittings.
Host machine (including 4 columns, 2 guide columns, base, top plate) ×1 set
Hoisting mechanism ×1 set
Hook mechanism ×1 set
Drop hammers (UL standards 9.1kg, 34kg) ×1 set
Anvils (Impact test anvil) ×1 set
Anvils (UL Standards anvils: right cylindrical and rectangular) ×1 set
Safety protection device ×1 set
Computer operation control system ×1 set
Brand name computer ×1 set
Falling Weight Impact Tester TFWT-A11
Falling Weight Impact Tester TFWT-A11

Models of Plastic Testing Instruments

Labtron Plastic Testing Instruments has a microprocessor-controlled PID system that ensures precise temperature balance for consistent results. These include an inside chamber constructed from durable stainless steel, offering long-lasting reliability. Their test samples retain their physical properties even after aging, ensuring accurate assessments. They have adopted a double-pipe structure for enhanced durability and performance. Our plastic testing instruments effectively determine the anti-impact properties of materials, providing valuable data for material testing and quality control.

Pendulum Impact Tester LIPT-A10

Pendulum Impact Tester LIPT-A10

  • Maximum Impact Energy : 3 J
  • Minimum Graduation Value : 0.020 J (Option: 0.010 J)
  • Pendulum Lifting Angle : 90°
  • Pendulum Swing Radius : 265 mm
Primary adhesive tester TPAT-A10

Primary adhesive tester TPAT-A10

  • Inclined adjustable angle : 0 to 40°
  • Panel width : 120 mm
  • Test area width : 80 mm
  • Standard steel balls : 1/32 to 1 inch
Melt flow Indexer TMFI-A11

Melt flow Indexer TMFI-A11

  • Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate : 0.001 S
  • Temperature range : 50 to 400°C
  • Temperature precision : ± 0.5°C
Melt Flow Indexer LMTF-A10
Melt Flow Indexer LMTF-A10
  • Temperature Control Range : 0℃ to 450℃
  • Temperature Resolution : 0.1℃
  • Temperature Fluctuation : ± 0.2℃
  • Temperature Uniformity : ± 1℃
Heat Seal Tester LHST-A11
Heat Seal Tester LHST-A11
  • Heat Sealing Temperature : RT to 300℃
  • Temperature Control Accuracy : ± 1℃ (0.1℃ customizable)
  • Heat Sealing Time : 0.01 s to 99.99 h
  • Heat Sealing Pressure : 0 to 8 kg (0 to 0.8 MPa)
Vacuum Leak Tester TVLT-A10

Vacuum Leak Tester TVLT-A10

  • Vacuum degree : 0 to 90 KPa
  • Accuracy : 1 % FS
  • Resolution : 0.1 KPa
  • Vacuum chamber effective size : 270 × 210 mm
Falling Weight Impact Tester LFWIT-A10

Falling Weight Impact Tester LFWIT-A10

  • Dart Head Mass : 50 to 2000
  • Mass Increment : 5 g
  • Impact Height : 1500 mm
  • Dart Head Quality : A method: R38 ± 1 mm B method: R50 ± 1 mm
Oxygen Index Tester TOIT-A10

Oxygen Index Tester TOIT-A10

  • Resolution : 0.1 % O2
  • Measuring range : 0 to 100 % O2
  • Precision : ± 0.4 % O2
  • Response time : < 10 S