| Max Speed | 8000rpm |
| Max RCF | 1180×g |
| Max Capacity | 6×1000 ml |
| Timer Range | 1 s to 99 min 59 s |
| Speed Accuracy | ±10 rpm |
| Noise Level | Less than equal to 62 dB(A) |
| Power Supply | AC 220 V 50 Hz 30A |
| Power | 6500 W |
| Dimensions (W×D×H) | 860×730×1200 mm |
| Net Weight | 270 kg |
Instantaneous Centrifugation Performance
Large-volume sample handling
Wide temperature control capability
Durable direct-drive motor system
Low-noise operation
User-friendly touch screen interface
Our Refrigerated Centrifuge LRF-E20 ideal for use in industrial labs, hospitals, and pharmaceutical laboratories. It ensures consistent performance for labs requiring high-speed, programmable runs with enhanced safety and user convenience
| Rotor Type | Capacity (ml) | Maximum Speed (r/min) | Maximum RCF (×g) |
| Fixed Angle Rotor 01 | 6 × 500 ml | 8000r/min | 11880×g |
| Fixed Angle Rotor 02 | 6 × 1000 ml | 7000r/min | 11630×g |
Download catalog for
Refrigerated Centrifuge LRF-E20 Catalog
Available Range :
Refrigerated Centrifuge LRF-C33 : 10000r/min Refrigerated Centrifuge LRF-E15 : 10000rpm Refrigerated Centrifuge LRF-A19 : 16000rpm Refrigerated Centrifuge LRF-B27 : 16500 rpm Refrigerated Centrifuge LRF-A18 : 16500rpm Refrigerated Centrifuge LRF-B28 : 18000 rpm Refrigerated Centrifuge LRF-A13 : 20000 rpm Refrigerated Centrifuge LRF-A15 : 21000rpm Refrigerated Centrifuge LRF-E22 : 22000 rpm Refrigerated Centrifuge LRF-E21 : 22000rpm Refrigerated Centrifuge LRF-E12 : 23000 rpm Refrigerated Centrifuge LRF-A16 : 25000 rpm Refrigerated Centrifuge LRF-E14 : 25000rpm Refrigerated Centrifuge LRF-B25 : 30,000 rpm Refrigerated Centrifuge LRF-A17 : 30000rpm Refrigerated Centrifuge LRF-B41 : 5500 rpm Refrigerated Centrifuge LRF-B43 : 5500rpm Refrigerated Centrifuge LRF-B42 : 6500rpm Refrigerated Centrifuge LRF-E19 : 8000rpmLabtron Refrigerated Centrifuge provide 5,000rpm to 50,000rpm speed to spin samples while maintaining controlled low temperature. They prevent heat buildup from affecting temperature-sensitive samples, such as biological materials, cells, proteins, nucleic acids, and blood. Their control panel includes programmable settings, enabling users to customize speed, time and thermal condition. They include various rotor options to accommodate different sample types and separation needs efficiently. Our Refrigerated Centrifuge is essential in molecular biology, clinical diagnostics, biochemistry, and microbiology.








The Refrigerated Centrifuge LRF- E20 is designed to efficiently handle common sample types like blood, cell suspensions, and biological fluids, making it a dependable choice for daily lab routines. Its consistent temperature control helps preserve sensitive samples during longer spins. Lab personnel benefit from the user-friendly interface and simplified cycle setup, which help accelerate workflows and enhance productivity The model balances ease of use with reliability, reducing training time for new users.
Labtron’s Refrigerated Centrifuge LRF- E20 features a built-in cooling system that actively regulates internal temperature, even during extended runs. This helps maintain sample integrity by reducing the risk of thermal degradation or unwanted reactions. The system cools quickly and remains stable throughout, making it ideal for temperature-sensitive applications.
The Refrigerated Centrifuge LRF-E20 includes safety mechanisms such as automatic imbalance detection and secure lid locking to prevent operation when the chamber isn’t fully closed. These features help minimize the risk of injury or sample loss during operation. The centrifuge also halts spinning safely in the event of a fault, giving users peace of mind.
The Refrigerated Centrifuge LRF -E20 is engineered to support high-efficiency workflows by offering rapid acceleration and deceleration, significantly reducing the time needed for each centrifugation cycle. Its fast-pre-cooling feature quickly brings the chamber to the desired temperature, allowing labs to process temperature-sensitive samples without waiting. Pre-set run programs and memory recall functions eliminate repetitive setup steps, ensuring quick transitions between cycles. It is particularly valuable in high-throughput environments where time and accuracy are critical, helping laboratories maintain a fast pace without sacrificing consistency, sample quality, or operator control.
Labtron’s Refrigerated Centrifuge LRF- E20 accommodates a variety of rotor options that make it flexible for handling different tube sizes and sample volumes. Whether you're processing microtubes or larger sample containers, the machine can be configured accordingly. This adaptability makes it ideal for labs with changing needs or multiple workflows. It ensures reliable separation across sample types, improving lab efficiency and reducing the need for multiple devices.
Our Refrigerated Centrifuge LRF-E20 is well-suited for biosafety environments, where contamination control and operator protection are top priorities. It features sealed rotor options that minimize the risk of aerosol dispersion during and after centrifugation, significantly reducing the chance of exposure to hazardous or infectious materials. The secure lid-lock mechanism ensures the chamber remains sealed throughout operation, further enhancing safety. Additionally, its smooth, corrosion-resistant construction support routine decontamination protocols essential in biosafety settings