 Table Top Spectrophotometer LTS-B16 offers the observer angle of 2° and 10° to provide improved visual accuracy from different viewing distances. The spectrophotometer has multi-illuminant selection option, allowing accurate color evaluation across multiple light sources. It has an inter-instrument error feature, minimizing variations between different instruments. Our table top spectrophotometer has an auto-identity measuring aperture , providing automatic adjustment to maintain high-quality color data.

Table Top Spectrophotometer LTS-B16
Table Top Spectrophotometer LTS-B16
Table Top Spectrophotometer LTS-B16
Table Top Spectrophotometer LTS-B16
Request Quote
Viewing Angle 2° and 10°
Wavelength Pitch 10nm
Semiband Width 5nm
Sensor 256 Images Element Double Array CMOS Image Sensor
Reflectance Range 0 to 200 %
Measurement Time 2.4 s
Measurement Aperture Reflective: Φ30mm / Φ25.4mm, Φ 18mm / Φ 15mm, Φ 10mm / Φ8mm, Φ 6mm/ Φ 4mm
Transmissive : Φ30mm / Φ 25.4mm
Sphere Size Φ154mm
Illuminant 360 – 780 nm Xenon lamp, 400 / 420 / 460 nm cut-off
Optical Geometry Reflect : D/8
Transmission: D/0
Repeatability Standard deviation 0.06 %
Standard deviation ΔE × ab 0.012
Illuminants D 65, A , C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, DLF, TL83, TL84, TPL5, U30.
Color Spaces CIE LAB, XYZ, Yxy, LCh, CIE LUV
Musell, s-RGB Hunter Lab, Bxy, DIN Lab99
Color Difference ΔE ab, ΔE uv, ΔE 94, ΔE cmc (2:1), ΔE ×cmc (1:1)
ΔE 00, DIN Δ E99, ΔE(Hunter)
Calorimetric Index WI( ASTM E313, CIE/ ISO, AATCC, Hunter)
YI(ASTM D1925, ASTM 313)
MI (Metamerism Index )
Staining Fastness, Color Fastness, Color Strength, Opacity, 8˚
Glossiness , Gardner Index, Haze , APHA / Pt – Co Index, 555
Index, Haze (ASTM D1003)
Saybolt , Color code (ASTM D1500)
Inter- Instrument Error Φ 25.4 mm / SCI ΔE × ab 0.12
Data Storage Capacity Standard : 5000 Pcs
Sample : 40000 Pcs
Power Consumption DC 24 V, 3A
Dimensions ( L× W× H) 370 × 300 × 200 mm
Weight 9.6 kg
  • Environmental Condition Sensing

  • Extensive wavelength range

  • Low maintenance design

  • Enhanced Signal Stability

  • Built-in barcode scanner

Table Top Spectrophotometer LTS-B16 is an analytical instrument used in precise color analysis and transmission in laboratories. It is widely applied in industries such as plastics, electronics and paper for quality assurance and material analysis.

Accessories Name

Quantity

Power Adapter

1

USB Cable

1

Transmissive Test Component

1

Transmission Black Baffle

1

 Fixing Frame Sample Holder

1

Micro Aperature (4mm)

1

Standard Calibration Board

1

Transmission Blackboard

1

Models of Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table Top Spectrophotometer LTS-A15

Table Top Spectrophotometer LTS-A15

  • Wavelength Range : 400 nm to 700 nm
  • Wavelength Interval : 10 nm
  • Sensor : High sensitivity silicon photodiode
  • Light Source : LED
Table Top Spectrophotometer LTS-B10

Table Top Spectrophotometer LTS-B10

  • Wavelength Range : 360 to 780 nm
  • Wavelength Pitch : 10nm
  • Sensor : 256 Images Element Double arrays
  • Sphere Size : Φ154mm
Table Top Spectrophotometer LTS-B11

Table Top Spectrophotometer LTS-B11

  • Sphere Size : Φ154mm
  • Wavelength Range : 360 to 780 nm
  • Sensor : 256 Images Element Double Arrays
  • Wavelength Pitch : 10nm
Table Top Spectrophotometer LTS-B17
Table Top Spectrophotometer LTS-B17
  • Storage Capacity : Standard: 2000 Pcs Sample: 20000 Pcs
  • Wavelength Pitch : 10nm
  • Semiband Width : 5nm
  • Sensor : 256 Images Element Double Array CMOS Image Sensor
Table Top Spectrophotometer LTS-B13
Table Top Spectrophotometer LTS-B13
  • Viewing Angle : 2° / 10°
  • Wavelength Range : 360 to 780nm
  • Sensor : 256 Images Element Double arrays
  • Sphere Size : Φ154mm
Table top spectrophotometer LTS-A10

Table top spectrophotometer LTS-A10

  • Illumination system : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array
Table top spectrophotometer LTS-A12

Table top spectrophotometer LTS-A12

  • Illumination system : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 15.2 cm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array
Table top spectrophotometer LTS-A11

Table top spectrophotometer LTS-A11

  • Illumination system : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array

Table Top Spectrophotometer LTS-B16 FAQ's
  • Labtron’s Tabletop Spectrophotometers are provided with UV capabilities and can measure light in the ultraviolet spectrum, typically below 400 nm. This is critical for analyzing optical brightening agents (OBAs), UV-sensitive materials, and certain chemicals. In industries like textiles and paper, UV light affects perceived whiteness and brightness. Including UV in color measurements ensures accurate evaluation of materials exposed to daylight. These instruments often allow UV calibration or switching between UV-included and UV-excluded modes. UV measurement also aids in identifying contaminants and fluorescence. It’s especially useful in research and quality control environments that deal with optical effects.

  • Labtron manufactures advance Table Top Spectrophotometer, most models are designed to operate within controlled environmental ranges (e.g., 20–25°C, 40–60% RH). Condensation can cloud optics or degrade calibration tiles. Thermal expansion or contraction of materials can alter optical paths. High humidity may affect paper or textile samples, changing their reflectance. Regular calibration and environmental monitoring help mitigate these effects. Using the instrument in a climate-controlled lab ensures stable and reproducible results. Some models include built-in sensors to alert for out-of-spec conditions.

  • Labtron supplies advanced Table Top Spectrophotometer. This setup compensates for lamp fluctuations, drift, and stray light in real-time, enhancing long-term stability. It's especially beneficial in low-reflectance or high-absorbance samples. By comparing both paths simultaneously, double-beam spectrophotometers reduce measurement noise and baseline variation. This design also supports faster scanning with higher accuracy. High-end lab models feature this architecture for advanced research, formulation, and high-stakes QC environments like pharmaceuticals or aerospace coatings.

  • Labtron’s Table Top Spectrophotometers have advanced temperature controlling options. The spectrophotometers monitor internal thermal fluctuations and apply correction algorithms in real time. This stabilizes readings across multiple measurements and long shifts. Advanced models log temperature variation with each reading for traceability. This feature enhances instrument repeatability and reduces ?E inconsistencies. It’s particularly valuable in fast-paced manufacturing where measurements are taken in varied conditions. It also helps maintain alignment with master color standards. This technology improves confidence in QC even under non-ideal lab conditions.

  • Labtron supplies Table Top Spectrophotometer with UV cut-off filters or programmable UV control allow users to exclude or standardize UV influence. Tabletop spectrophotometers with turnable UV LED sources or automated filters enable OBAs to be measured under controlled conditions. This is essential in paper, textiles, and detergents. Without UV control, brightness and whiteness indices can vary drastically, impacting product consistency. Consistent UV management also supports regulatory compliance. It helps accurately quantify and compare OBA performance across products.

  • Labtron manufactures high-end Table Top Spectrophotometers which use positioning jigs, automated sample holders, or rotating optics to minimize operator-induced variability. Even slight changes in sample positioning can affect the color measurement. Repeatability improves with alignment tools, foot switches, or contact pressure stabilization. Measurement area (aperture size) also impacts sensitivity to misalignment. Instruments offering customizable aperture sizes allow better matching to sample geometry. Software-controlled sample tracking logs positions and averages multiple readings for better confidence. This is critical for irregular shapes, textiles, or curved surfaces. Consistent sample orientation is key for long-term QC precision.

Post your question?

Our experts are here to help!

Table Top Spectrophotometer:
Table Top Spectrophotometer LTS-A15, Table Top Spectrophotometer LTS-B10, Table Top Spectrophotometer LTS-B11, Table Top Spectrophotometer LTS-B17, Table Top Spectrophotometer LTS-B13, Table top spectrophotometer LTS-A10, Table top spectrophotometer LTS-A12, Table top spectrophotometer LTS-A11, and more.

Quick Links : About Us, Contact Us, User Manuals, Career, Terms of Use, Policies, Sitemap, Gallery.

Need a Product

send details for best price quotation

Click
For

Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.