Temperature and Humidity Test Chamber LTHC-H15 features a φ10 mm soft silicone drainpipe for efficient water discharge. It includes overload and short-circuits protection for enhanced safety. A stainless-steel round bar sample rack ensures secure placement of test items. It features sensors located at the air outlet to ensure precise monitoring of internal environmental conditions. Our chamber supports reliability and environmental testing such as cold, dry heat, steady damp heat, and damp heat cyclic conditions.

Temperature And Humidity Test Chamber LTHC-H15_front view
Temperature And Humidity Test Chamber LTHC-H15_front view
Temperature And Humidity Test Chamber LTHC-H15_side view
Temperature And Humidity Test Chamber LTHC-H15_front view
Request Quote
Capacity 64 L
Temperature Range - 40 ℃ to + 150 ℃ (Optional + 180 ℃)
Temperature Uniformity ± 2.0 °C
Temperature Fluctuation ± 0.5 ℃
Temperature Deviation ± 2.0℃
Temperature Resolution + 0.1 ℃
Heating Rate - 40 ℃ to + 100 ℃
Cooling Rate + 20 ℃ to – 40 ℃
Humidity Range 20 % to 98 % R.H
Humidity Uniformity ± 3 % R.H
Humidity Fluctuation ± 2.0 % R.H
Humidity Deviation ±3.0 % / 5.0 % R.H
Humidity Resolution + 0.1 %
Ambient Temperature 5 °C to 35 °C
Humidifier Type Stainless-steel electric heating humidifier
Compressor Copeland or Tecumseh or Sanyo compressor
Controller 7-inch touch screen controller
Centrifugal Blower Multi-wings centrifugal blowers with aluminum alloy blades
Display Type 7-inch LED touch screen
Communication Interface USB, RS-485, and WLAN (Optional)
Evaporator High efficiency multi-stage fin type evaporator
Refrigeration System Single stage refrigeration system with R404A refrigerant
Drainage Port φ10 mm soft silicone drain pipe
Noise ≦ 75 (dB)
Exterior Chamber Material High-quality carbon steel with painting
Interior Chamber Material SUS304 matte stainless-steel plate
Insulation Material Rigid polyurethane foam insulation, flame retardant grade B2
Power Consumption 5 KW
Power supply AC 380V ±10% 50Hz / AC 220V ±10% 50Hz
Internal Dimensions 400 × 400 × 400 mm
External Dimensions 700 × 1652 × 1170 mm
Package Dimensions 920 × 1820 × 1350 mm
Net Weight 320 Kg
Gross Weight 350 Kg
  • Interior Anti-Corrosion Coating

  • Integrated Dry Run Protection

  • Energy Efficient Compressor Technology

  • Quick Defrost Function

  • PID Control System 

Our chamber is engineered for reliability and environmental testing, including cold, dry heat, steady-state damp heat, and cyclic damp heat, ensuring product durability across diverse climatic and stress conditions.

Accessories

Quantity

Unit

Window light

1

Set

Mobile casters (with foot cups)

4

Pieces

50mm lead holes (with silicone plugs)

2

Units

Sample racks

2

Layers

Lighting set

1

Set

Power cord

5

Meters

  • Shelves

Temperature And Humidity Test Chamber LTHC-H15 | Capacity: 64 L | Temperature Uniformity: ± 2.0 °C
Temperature And Humidity Test Chamber LTHC-H15 | Interior Anti-Corrosion Coating | Integrated Dry Run Protection

Models of Temperature and Humidity Test Chamber

Labtron offers temperature and humidity test chambers with capacities ranging from 50 to 1130 L. They have a humidity controller and thermal-insulating material resistant to high temperatures. They feature an LCD touch screen with a corrosion-resistant interior chamber and a double-layered glass observation window. They include an independent R&D software and a compressor overload switch. Our temperature and humidity tester has built-in safety self-protection and overheating prevention.

Temperature And Humidity Test Chamber LTHC-H17

Temperature And Humidity Test Chamber LTHC-H17

  • Capacity : 225 L
  • Temperature Range : - 40 ℃ to + 150 ℃ (Optional + 180 ℃)
  • Temperature Uniformity : ± 2.0 °C
  • Temperature Fluctuation : ± 0.5 ℃
Temperature and Humidity Test Chamber LTHC-B14

Temperature and Humidity Test Chamber LTHC-B14

  • Capacity : 1000 L
  • Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃
  • Temperature cooling rate : 1 ℃ / min
  • Overall dimension (D x W x H) : 1500 x 1550 x 2110 mm
Temperature And Humidity Test Chamber LTHC-E25

Temperature And Humidity Test Chamber LTHC-E25

  • Capacity : 408 L
  • Temperature Range : -70℃ to +150℃
  • Temperature Fluctuation : ±0.5℃
  • Temperature Uniformity : ≤2.0℃
Temperature And Humidity Test Chamber LTHC-H12
Temperature And Humidity Test Chamber LTHC-H12
  • Capacity : 225 L
  • Temperature Range : - 20 ℃ to + 150 ℃ (Optional + 180 ℃)
  • Temperature Uniformity : ≦ 2.0 °C
  • Temperature Fluctuation : ± 0.5 ℃
Temperature and Humidity Test Chamber LTHC-B25
Temperature and Humidity Test Chamber LTHC-B25
  • Capacity : 1500 L
  • Temperature range : (-60) ℃ to +150 ℃
  • Environmental conditions : 5℃ to +35 ℃ ≤ 85% RH
  • Loading weight : ≥ 150 Kg
Temperature and Humidity Test Chamber LTHC-D10

Temperature and Humidity Test Chamber LTHC-D10

  • Capacity : 300L
  • Heat Load : 1000W
  • Temperature Range : -20℃ to 180 ℃
  • Temperature Accuracy : ± 2.0 ℃
Temperature And Humidity Chamber LTHC-G11

Temperature And Humidity Chamber LTHC-G11

  • Capacity : Total of 800L
  • Temperature Range : 10 to 65℃ with light
  • Temperature Fluctuation : ±0.5
  • Temperature Uniformity : ±2℃
Temperature And Humidity Test Chamber LTHC-H10

Temperature And Humidity Test Chamber LTHC-H10

  • Capacity : 64 L
  • Temperature Range : - 20 ℃ to + 150 ℃ (Optional + 180 ℃)
  • Temperature Uniformity : ≦ 2.0 °C
  • Temperature Fluctuation : ± 0.5 ℃
Temperature And Humidity Test Chamber LTHC-H15 FAQ's
  • Routine maintenance is essential to keep the chamber functioning accurately and reliably. Users should regularly inspect the door seals to prevent air leakage that could affect internal conditions. The water tank and humidifier should be cleaned periodically to avoid mineral buildup and microbial contamination. Filters on air circulation units and condensers must be checked and replaced as needed. It’s also important to verify sensor calibration at regular intervals for accurate readings. Any unusual noises or fluctuations should be reported and diagnosed early.

  • Humidity control is achieved by either adding moisture through a steam generator or reducing it using a dehumidification system. The chamber contains precise sensors that continuously monitor relative humidity inside. Based on readings, the control system adjusts humidity levels by activating the humidifier or the cooling coil for condensation. The use of distilled or deionized water is often recommended to avoid scaling. Advanced chambers can control humidity between 20% to 98% depending on the model. Stable humidity conditions are crucial for reliable material testing. Accurate control helps meet regulatory testing standards in various industries.

  • The Temperature And Humidity Test Chamber LTHC-H15 is extensively used in a variety of industries for quality control and product development. The electronics industry uses them to check circuit board and component reliability under humidity stress. In pharmaceuticals, they test drug stability under ICH-recommended storage conditions. Automotive manufacturers evaluate how parts respond to environmental aging. Aerospace, textile, plastic, and battery industries also rely on such chambers for compliance and research. Even academic and government laboratories use them for controlled environmental simulations. Their versatility makes them essential across both industrial and scientific fields.

  • Yes, Temperature And Humidity Test Chamber LTHC-H15 is used to recreate extreme environmental conditions. They can simulate freezing arctic climates or hot and humid tropical environments depending on the model. This is particularly useful for testing the durability of products like electronics, automotive parts, or packaging materials. Rapid temperature changes can also be programmed to simulate conditions during transport or storage. The data collected helps manufacturers predict product behavior under various stress levels. Chamber allow repeatable testing that would be difficult or costly to replicate in the natural environment. These simulations support robust product design and quality assurance.

  • Water quality plays a crucial role in the performance of the Temperature and Humidity Test Chamber LTHC-H15, especially in its humidification system. Poor water quality can lead to scaling, corrosion, and sensor damage, compromising test accuracy and chamber durability. It is recommended to use deionized, distilled, or RO-purified water to avoid mineral buildup and ensure consistent humidity levels. A clean and stable water supply helps maintain the efficiency of steam generators and internal pipelines. The chamber may include filtration components or alarms to indicate water quality issues. Neglecting water standards can result in reduced humidity control and potential equipment failures. Regular maintenance, including filter checks and water tank cleaning, supports long-term chamber reliability.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.