Melting Point Apparatus LDMP-B11 offers desktop design, Semi- automatic detection method, with cooling function. Equipped with Peltier precise temperature function, In line with international standards such as CE & ISO for determination of the melting point of oils and fats. With addition of either high-definition camera or high definition video and camera technology, to delivers accurate, stable results, and user can clearly see the whole process of sample melting, automatic detection to eliminate the subjective error to determine the melting point.

Request Quote
Temperature control range 6 to 100℃
Detection method Semi-automatic
Capacity per batch 2 pcs/batch
Temperature resolution 0.1℃
Temperature gradients (0.1 to 10.0)℃/Min
Temperature accuracy ±0.3℃
Repeatability 0.1℃/Min , ±0.1℃
Camera & Video Camera & Video
Video playback Yes
Operator account 8
Result storage 400
SD card capacity 8G
Display TFT Touch screen
Interface USB RS232 SD card Enternet
Opening capillary size I.D>1.0 mm, O.D.1.4 mm Double opening
Power 110 to 220V 50, 60HZ 120W
Dimension 400 × 280× 330 mm
Weight 5 kg
  • TFT touch screen display
  • Semi- automatic detection method, with cooling function
  • Capacity per batch is 2 pcs
  • Designed with a key automatic detection function
  • Use of double opening capillary size I.D>1.0 mm,O.D.1.4 mm
  • In line with international standards such as CE & ISO
  • Adopted with Peltier precise temperature function technology

It finds application across finding meting point of oil and fat in food and drug industry, biochemistry, medicines, mining, water management industry.

Melting Point Apparatus LDMP-B11 | Temperature control range: 6 to 100℃ | Temperature resolution: 0.1℃
Melting Point Apparatus LDMP-B11 | TFT touch screen display | Automatic detection function

Models of Touch Screen Melting Point Apparatus

Labtron Touch Screen Melting Point Apparatus offers temperature upto 420℃ with touch display at which solid turns into liquid. They feature heating block that ensures uniform thermal distribution. Their construction includes capillary tube that holds sample in place for accurate determination. They include optical system to clearly observe transition of sample. Our Touch Screen Melting Point Apparatus is suitable for purity testing, compound characterization, environmental analysis and forensic analysis.

Melting Point Apparatus LDMP-A25

Melting Point Apparatus LDMP-A25

  • Temperature Range : 10°C to 100°C
  • Detection Method : Full automatic
  • Processing Capacity : 3 / batch
  • Temperature Resolution : 0.1°C
Melting Point Apparatus LDMP-A21

Melting Point Apparatus LDMP-A21

  • Temperature Range : Room temperature to 360℃
  • Detection Method : Fully automatic (compatible with manual)
  • Processing Capacity : 4 pcs per batch
  • Temperature Resolution : 0.01℃
Melting Point Apparatus LDMP-A33

Melting Point Apparatus LDMP-A33

  • Temperature Range : RT to -400°C
  • Detection Method : Fully automatic
  • Processing Capacity : 4 / batch
  • Temperature Resolution : 0.01°C
Melting Point Apparatus LDMP-A34
Melting Point Apparatus LDMP-A34
  • Temperature Range : RT to -420°C
  • Detection Method : Fully automatic
  • Processing Capacity : 4 / batch
  • Temperature Resolution : 0.01°C
Melting Point Apparatus LDMP-A31
Melting Point Apparatus LDMP-A31
  • Temperature Range : 10°C to - 400°C
  • Detection Method : Semi- automatic
  • Processing Capacity : 4 / batch
  • Temperature Resolution : 0.1°C
Melting Point Apparatus LDMP-B10

Melting Point Apparatus LDMP-B10

  • Temperature control range : RT to 100℃
  • Detection method : Semi-automatic
  • Capacity per batch : 2 pcs/batch
  • Temperature resolution : 0.1℃
Melting Point Apparatus LDMP-A32

Melting Point Apparatus LDMP-A32

  • Temperature Range : RT to 350°C
  • Detection Method : Fully automatic
  • Processing Capacity : 4 / batch
  • Temperature Resolution : 0.1°C
Melting Point Apparatus LDMP-A20

Melting Point Apparatus LDMP-A20

  • Temperature range : Room temperature to 350 ℃
  • Detection mode : Fully automatic (compatible with manual)
  • Processing capacity : 4 / batch
  • Judgment ability : Automatically judge color samples

Melting Point Apparatus LDMP-B11 FAQ's
  • The Melting Point Apparatus LDMP-B11 is suitable for testing a wide range of substances including oils, fats, pharmaceuticals, and organic compounds. It is commonly used in industries such as food, cosmetics, environmental science, and biochemistry. It handles both crystalline and semi-solid samples effectively using standard capillaries. Its versatility makes it a practical tool for laboratories with diverse testing needs.

  • Our Melting Point Apparatus LDMP-B11, while designed primarily for precision, supports moderate throughput with dual-sample capacity and fast temperature ramping. Its quick setup and efficient operation enable labs to process multiple samples in succession with minimal downtime. With internal storage for up to 400 results, it helps streamline workflow. This makes it well-suited for quality control and routine lab testing.

  • The Melting Point Apparatus LDMP-B11 features a semi-automatic detection system that identifies melting points using visual and thermal signals, reducing manual observation. An integrated camera records the melting process for result verification. This enhances accuracy and supports training and audit documentation. The system ensures repeatability, essential for quality control and compliance.

  • Our Melting Point Apparatus LDMP-B11 features an integrated camera that captures real-time visuals of the melting process, eliminating the need for direct contact or a microscope. This visual data aids in confirming melting behavior and can be replayed for verification or training. It enhances user confidence and documentation, especially when evaluating borderline results. The video feature also minimizes the risk of missing subtle transitions during testing.

  • The test duration in Melting Point Apparatus LDMP-B11 depends on the selected temperature gradient and the nature of the sample. With faster gradients, the apparatus can complete tests more quickly, though slower gradients are often preferred for higher accuracy. In most routine applications, a test can be completed within a few minutes. The device is designed to balance speed and precision, ensuring efficient workflow in busy labs.

  • Labtron’s Melting Point Apparatus LDMP-B11 is generally safe to operate, users should handle heated components with care to avoid burns. Samples must be properly sealed in capillaries to prevent spillage or contamination during heating. It’s important to avoid touching the sample chamber immediately after a test, as internal parts may remain hot for a short time. Following standard lab safety protocols and reviewing the user manual before use is highly recommended.

Post your question?

Our experts are here to help!

Touch Screen Melting Point Apparatus:
Melting Point Apparatus LDMP-A25, Melting Point Apparatus LDMP-A21, Melting Point Apparatus LDMP-A33, Melting Point Apparatus LDMP-A34, Melting Point Apparatus LDMP-A31, Melting Point Apparatus LDMP-B10, Melting Point Apparatus LDMP-A32, Melting Point Apparatus LDMP-A20, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.