Request A Quote
Melting Point Apparatus LDMP-A25

Melting Point Apparatus LDMP-A25

Melting Point Apparatus LDMP-A25 offers a temperature range of 10°C to 100°C, providing precise PID temperature control and real-time sample observation. It includes capillary tube sample holders for the secure placement of samples in sealed capillaries, ensuring consistent melting point determination. The apparatus has an automatic shutoff mode, preventing overheating damage and ensuring lab safety. Our melting point apparatus is constructed from high-quality stainless steel and aluminum, delivering precise thermal conductivity and uniform heating.

Request Quote
Temperature Range 10°C to 100°C
Detection Method Full automatic
Processing Capacity 3 / batch
Temperature Resolution 0.1°C
Heat Range (0.1 to10.0) °C / min
Accuracy ± 0.3°C
Repeatability Heating Rate 0.1°C / min ± 0.1°C
Video Function Take pictures and Videos
Video Playback Yes
User Management 20
Results Saving 1000
Data Storage 32 GB
Display Mode TFT HD Color Screen
Data Interface USB RS232 SD Card RJ 45
Open Capillary Size I.D. 1.0 mm, O.D. 1.4 mm
Power Supply 110 to 220 V 50 Hz / 60 Hz
Power Consumption 120 W
  • Multi-Sample Testing

  • Overheat Protection Mode

  • Sample Chamber Illumination

  • High-Precision Temperature Sensors

  • Built-in Camera

Melting Point Apparatus LPDM-A25 is used for identifying substances and assessing purity via their melting behaviour It plays a key role in quality control laboratories, forensic sciences and material sciences for quality control and studying thermal properties.

Models of Touch Screen Melting Point Apparatus

Labtron Touch Screen Melting Point Apparatus offers temperature upto 420℃ with touch display at which solid turns into liquid. They feature heating block that ensures uniform thermal distribution. Their construction includes capillary tube that holds sample in place for accurate determination. They include optical system to clearly observe transition of sample. Our Touch Screen Melting Point Apparatus is suitable for purity testing, compound characterization, environmental analysis and forensic analysis.

Melting Point Apparatus LDMP-B11

Melting Point Apparatus LDMP-B11

  • Temperature control range : 6 to 100℃
  • Detection method : Semi-automatic
  • Capacity per batch : 2 pcs/batch
  • Temperature resolution : 0.1℃
Melting Point Apparatus LDMP-A13

Melting Point Apparatus LDMP-A13

  • Temperature Range : RT to 400°C
  • Cooling Function : Built-in Cooling Fan
  • Sample Cell : Capillary tube
  • Sample Tube : External diameter: 1.6 mm internal diameter: 1.2 mm
Melting Point Apparatus LDMP-A24

Melting Point Apparatus LDMP-A24

  • Temperature Range : RT to 350°C
  • Detection Method : Fully Automatic (Compatible with Manual)
  • Processing Capacity : 3 / batch
  • Temperature Resolution : 0.1°C
Melting Point Apparatus LDMP-A30
Melting Point Apparatus LDMP-A30
  • Temperature Range : RT to 350°C
  • Detection Method : Semi-automatic
  • Processing Capacity : 4 / batch
  • Temperature Resolution : 0.1°C
Melting Point Apparatus LDMP-B12
Melting Point Apparatus LDMP-B12
  • Temperature control range : RT to 100℃
  • Detection method : Fully automatic (compatible with Semi-automatic)
  • Capacity per batch : 2 pcs/batch
  • Temperature resolution : 0.1℃
Melting Point Apparatus LDMP-B13

Melting Point Apparatus LDMP-B13

  • Temperature control range : 4 to 100℃
  • Detection method : Fully automatic (compatible with Semi-automatic)
  • Capacity per batch : 2 pcs/batch
  • Temperature resolution : 0.1℃
Melting Point Apparatus LDMP-A33

Melting Point Apparatus LDMP-A33

  • Temperature Range : RT to -400°C
  • Detection Method : Fully automatic
  • Processing Capacity : 4 / batch
  • Temperature Resolution : 0.01°C
Melting Point Apparatus LDMP-B10

Melting Point Apparatus LDMP-B10

  • Temperature control range : RT to 100℃
  • Detection method : Semi-automatic
  • Capacity per batch : 2 pcs/batch
  • Temperature resolution : 0.1℃

Melting Point Apparatus LDMP-A25 FAQ's
  • Labtron’s melting point apparatus LDMP-A25 use PID (Proportional Integral Derivative) control, which constantly adjusts heating based on the difference between target and actual temperature. This keeps temperature steady without overshooting or lag. It means your sample warms up smoothly, so you see sharper melting transitions and more reproducible results. PID control also adapts over time, tuning itself for different heating rates or sample masses. Compared to simple on/off heaters, PID gives you tighter accuracy and saves time by avoiding trial-and-error adjustments.

  • Labtron supplies premium melting point apparatus LDMP-A25. Accurate melting point measurements depend on how the sample is both heated and cooled. Automatic cooling systems-like built-in fans or Peltier modules-bring the apparatus back down to starting temperature quickly and evenly. That way, each new sample starts from the same baseline. Rapid, controlled cooling also preserves the calibration of the heating block by preventing overheating. In contrast, slow or uneven cooling could cause drift, unpredictable heating behaviour, and inconsistent results over time.

  • Labtron supplies premium melting point apparatus LDMP-A25.Calibration involves measuring certified reference standards-like benzoic acid or naphthalene-at multiple points across the instrument's range. Adjust any offsets if measured values fall outside tolerance limits, then verify with different references to confirm accuracy. Many systems support up to five-point calibration and generate performance certificates for regulatory compliance. Routine checks before experiments help detect drift and maintain confidence in your data.

  • Labtron supplies premium melting point apparatus LDMP-A25. Deviations from expected values may arise from impurities (which lower and broaden the range), overheating (from too-fast heating), and poor capillary packing. Calibration errors or a failing temperature sensor can also cause anomalies in readings. Use two samples-one known and one unknown-to isolate whether the problem is the sample or the instrument. Troubleshooting by reviewing prep, settings, and system performance ensures reliable outcomes.

  • Labtron’s advanced melting point apparatus LDMP-A25 instruments include built-in cameras that record videos or capture images of the melting tube. This allows software to automatically detect the start and end of melting, reducing operator subjectivity and improving precision. Video playback on a touchscreen offers visual confirmation and auditability. Multichannel systems can simultaneously analyse several samples. These features support compliance requirements like 21?CFR?11 with timestamped data and user logs, and streamline workflows in high-throughput or regulated labs.

Post your question?

Our experts are here to help!

Touch Screen Melting Point Apparatus:
Melting Point Apparatus LDMP-B11, Melting Point Apparatus LDMP-A13, Melting Point Apparatus LDMP-A24, Melting Point Apparatus LDMP-A30, Melting Point Apparatus LDMP-B12, Melting Point Apparatus LDMP-B13, Melting Point Apparatus LDMP-A33, Melting Point Apparatus LDMP-B10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.