Request A Quote
Melting Point Apparatus LDMP-A24

Melting Point Apparatus LDMP-A24

Melting Point Apparatus LDMP-A24 features a processing capacity of 3 samples per run for simultaneous sample analysis and improved resource efficiency. It is equipped with an integrated cooling fan, maintaining temperature transitions for precise melting point analysis. The apparatus is constructed from high-quality stainless steel and aluminum for precise thermal conductivity and even heating. Our melting point apparatus has an automatic shutoff mode, preventing overheating damage and ensuring lab safety.

Request Quote
Temperature Range RT to 350°C
Detection Method Fully Automatic (Compatible with Manual)
Processing Capacity 3 / batch
Temperature Resolution 0.1°C
Heat Range (0.1 to10.0) °C / min
Accuracy ± 0.3°C
Repeatability Heating Rate 0.1°C at 0.1°C / min
Video Function Take pictures
Video Playback No
User Management 10
Results Saving 600
Data Storage 16 GB
Display Mode TFT HD Color Screen
Data Interface USB RS232 SD Card RJ 45
Open Capillary Size I.D. 1.0 mm, 0.D to 1.4 mm
Power Supply 110 to 220 V 50 Hz / 60 Hz
Power Consumption 120 W
  • PID Temperature Controlled Mode

  • Multi-Sample Testing

  • Capillary Tube Sample Holders

  • Automated Melt Detection

  • Optical / Magnification System

Melting Point Apparatus LDMP-A24 allows fast and precise melting point analysis with user-friendly touch-based operation. It is applied in academic and research institutions, chemicals, and pharmaceutical sectors for verifying the purity of active ingredients.

Models of Touch Screen Melting Point Apparatus

Labtron Touch Screen Melting Point Apparatus offers temperature upto 420℃ with touch display at which solid turns into liquid. They feature heating block that ensures uniform thermal distribution. Their construction includes capillary tube that holds sample in place for accurate determination. They include optical system to clearly observe transition of sample. Our Touch Screen Melting Point Apparatus is suitable for purity testing, compound characterization, environmental analysis and forensic analysis.

Melting Point Apparatus LDMP-A22

Melting Point Apparatus LDMP-A22

  • Temperature Range : RT to 350°C
  • Detection Method : Semi-automatic
  • Processing Capacity : 3 / batch
  • Temperature Resolution : 0.1°C
Melting Point Apparatus LDMP-B11

Melting Point Apparatus LDMP-B11

  • Temperature control range : 6 to 100℃
  • Detection method : Semi-automatic
  • Capacity per batch : 2 pcs/batch
  • Temperature resolution : 0.1℃
Touch Screen Melting Point Apparatus LDMP-B14

Touch Screen Melting Point Apparatus LDMP-B14

  • Temperature control range : Room temperature to 420 ℃
  • Detection method : Fully automatic
  • Capacity per batch : 4 pcs/batch
  • Temperature resolution : 0.01 ℃
Melting Point Apparatus LDMP-A13
Melting Point Apparatus LDMP-A13
  • Temperature Range : RT to 400°C
  • Cooling Function : Built-in Cooling Fan
  • Sample Cell : Capillary tube
  • Sample Tube : External diameter: 1.6 mm internal diameter: 1.2 mm
Melting Point Apparatus LDMP-A31
Melting Point Apparatus LDMP-A31
  • Temperature Range : 10°C to - 400°C
  • Detection Method : Semi- automatic
  • Processing Capacity : 4 / batch
  • Temperature Resolution : 0.1°C
Melting Point Apparatus LDMP-A23

Melting Point Apparatus LDMP-A23

  • Temperature Range : 10°C to 100°C
  • Detection Method : Semi-automatic
  • Processing Capacity : 3 / batch
  • Temperature Resolution : 0.1°C
Melting Point Apparatus LDMP-B12

Melting Point Apparatus LDMP-B12

  • Temperature control range : RT to 100℃
  • Detection method : Fully automatic (compatible with Semi-automatic)
  • Capacity per batch : 2 pcs/batch
  • Temperature resolution : 0.1℃
Melting Point Apparatus LDMP-A33

Melting Point Apparatus LDMP-A33

  • Temperature Range : RT to -400°C
  • Detection Method : Fully automatic
  • Processing Capacity : 4 / batch
  • Temperature Resolution : 0.01°C

Melting Point Apparatus LDMP-A24 FAQ's
  • . Labtron supplies advanced models of melting point apparatus LDMP-A24. Effective sample preparation starts by grinding your substance to a fine, dry powder to achieve uniform particle size, ensuring consistent thermal behavior. The powder should be carefully packed into a clean capillary tube, avoiding air gaps and external residue that could impact heat transfer or contaminate the instrument. Gently tapping the tube helps settle the sample at the bottom of the capillary, promoting precise melting transitions and reducing variability caused by uneven packing or moisture.

  • Labtron supplies advanced models of melting point apparatus LDMP-A24. A controlled heating process enhances melting point precision. Begin with a moderate temperature rise to approach the expected melting zone, then switch to slower, more gradual heating to clearly capture the onset and complete phase transition. Incorrect starting points or rapid ramping can cause overheating, thermal lag, or blurred melting observations. Following recommended protocols ensures more accurate and reproducible results.

  • Labtron supplies advanced models of melting point apparatus LDMP-A24. Calibration using certified melting point standards guarantees that the apparatus reads accurately across its operational range. Regular verification checks-even using a single reference-can reveal drift caused by wear, environmental shifts, or electronics aging. Maintaining logs of calibration and routine checks helps document performance stability and supports compliance with quality standards.

  • Labtron supplies advanced models of melting point apparatus LDMP-A24. Misleading results often stem from sample impurities (which depress melting points), overly rapid heating (masking true melting behavior), blocked light paths or dirty optical systems, or faulty temperature sensors. Troubleshooting involves inspecting and cleaning optics, verifying sensor calibration, replacing defective capillaries, and comparing sample readings with known references to isolate sample issues.

  • Labtron supplies advanced models of melting point apparatus LDMP-A24. To maintain instrument longevity and accuracy, keep the device in a dry, dust-free, and well-ventilated environment. Clean the sample holder and optical window before each run to prevent buildup. Use only approved capillaries and avoid inserting damaged or contaminated tubes. After use, power down and allow the block to cool safely before removing samples or cleaning, protecting both equipment and user.

Post your question?

Our experts are here to help!

Touch Screen Melting Point Apparatus:
Melting Point Apparatus LDMP-A22, Melting Point Apparatus LDMP-B11, Touch Screen Melting Point Apparatus LDMP-B14, Melting Point Apparatus LDMP-A13, Melting Point Apparatus LDMP-A31, Melting Point Apparatus LDMP-A23, Melting Point Apparatus LDMP-B12, Melting Point Apparatus LDMP-A33, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608