Touch Thermal Cycler (Gradient) LTCG-A24 features a block capacity of 96 × 0.2 mL, ideal for high-throughput PCR applications in standard 96-well plates. Offers both block and individual tube temperature control modes for specific experimental conditions. It includes a gradient calculator to easily determine the optimal annealing temperature. Our Thermal Cycler is used for gene amplification in PCR-based molecular biology and diagnostic applications.

Touch Thermal Cycler (Gradient) LTCG-A24_Front View
Thermal Cycler (Gradient) LTCG-A24_Side View
Touch Thermal Cycler (Gradient) LTCG-A24_Video
Request Quote
Capacity 96 × 0.2 mL
Temperature Range 4°C to 99°C
Maximum Heating Rate 4.5℃/s
Maximum Cooling Rate 4℃/s
Temperature Uniformity ±0.25℃
Temperature Accuracy ±0.25℃
Temperature Display Resolution 0.1°C
Temperature Control Method Block/Tube
Temperature Change Rate 0.1 to 5.0℃
Gradient Temperature Uniformity ±0.3℃
Gradient Temperature Accuracy ±0.3℃
Gradient Temperature Range 30 to 99.9℃
Gradient Setting Range 0.1 to 30℃
Hot Cover Temperature Range 30 to 110℃
Single Step Time Range 1 to 59m59s, 0 is forever
Hot Lid Height Adjustment Adjustable
Maximum Steps of the Program 30
Program Maximum Cycle Numbers 99
Time Increment / Decrement -599 to 599s
Temperature Increase / Decrement -9.9 to 9.9℃
Program Pause Function Yes
16℃ Insulation Forever
LCD Screen 8 inches
Program Storage Quantity Greater than 100
Communication Interface USB2.0, LAN
Fuse 250V, 8A Ф5×20
Power Supply AC100 to 240V, 6.6 to 3.1A, 50/60Hz
Dimension (W×D×H) 390 × 270 × 255 mm
Weight 8.5 kg
  • Rapid temperature control

  • High-resolution touchscreen

  • Integrated rapid incubation mode

  • Customizable programming options

  • Wide voltage compatibility

Touch Thermal Cycler (Gradient) LTCG-A24 is designed for efficient and accurate DNA amplification using PCR techniques. It is widely used in molecular biology labs, research institutes, clinical diagnostics, and genetic testing centers.

Touch Thermal Cycler (Gradient) LTCG-A24 | Capacity-96 × 0.2 mL | Temperature Range-4°C to 99°C
Touch Thermal Cycler (Gradient) LTCG-A24 | Rapid temperature control | High-resolution touchscreen


Models of Touch Thermal Cycler

Labtron Touch Thermal Cycler comes with the basic and gradient temperature functionality model. These cycler deliver rapid thermal cycling with high heating and cooling rates. They are equipped with stepless adjustable hot lids featuring pressure protection. The thermal cycler can accommodate various tube heights while preventing sample evaporation. For software updates and data transfer, they support USB and LAN connectivity. The email alert feature notifies users as soon as their experiment is finished. It can run single or dual independent programs simultaneously. They are built with safety features such as auto data protection and GLP-compliant report generation. Our Touch Thermal Cycler’s robust construction and corrosion-resistant materials ensure durability and long service life.

Touch Thermal Cycler (Gradient) LTCG-A15

Touch Thermal Cycler (Gradient) LTCG-A15

  • Sample Capacity : 96×0.2ml, PCR tube12×0.2ml,PCR-8 strips0.2ml,96 PCR Microplate
  • Gradient Temperature Setting Range : 30℃ to 105℃
  • Gradient Range : 1℃ to 42℃, enter 0 to turn off gradient
  • Heating Temperature : 0℃ to 105℃
Touch Thermal Cycler (Basic) LTCB-A14

Touch Thermal Cycler (Basic) LTCB-A14

  • Sample Capacity : 96×0.2ml, PCR tube12×0.2ml,PCR-8 strips0.2ml,96 PCR Microplate
  • Heating Temperature : 4℃ to 105℃
  • Lid Temperature : 30℃ to 110℃
  • Temperature Display Accuracy : ± 0.1℃at 55℃ is ± 0.3℃
Touch Thermal Cycler (Basic) LTCB-A13

Touch Thermal Cycler (Basic) LTCB-A13

  • Capacity : 3 × (32 × 0.2 ml )
  • Temperature Range : 0 to 100℃
  • Heating Rate : 5 ℃/s
  • Cooling Rate : 4 ℃/s
Touch Thermal Cycler (Gradient) LTCG-A10
Touch Thermal Cycler (Gradient) LTCG-A10
  • Capacity : 96 × 0.2 ml
  • Block Temperature Range : 0 to 100℃
  • Temperature Control Accuracy : ≤ ± 0.1 ℃
  • Ramping Rate Adjustable : 0.1 to 5℃
Touch Thermal Cycler (Gradient) LTCG-A14
Touch Thermal Cycler (Gradient) LTCG-A14
  • Sample Capacity : 96×0.2ml, PCR tube12×0.2ml,PCR-8 strips0.2ml,96 PCR Microplate
  • Gradient Temperature Setting Range : 30℃ to 99℃
  • Gradient Range : 1℃ to 42℃
  • Heating Temperature : 4℃ to 105℃
Touch Thermal Cycler (Gradient) LTCG-A22

Touch Thermal Cycler (Gradient) LTCG-A22

  • Capacity : 3 × (32 × 0.2 ml )
  • Temperature Range : 0 to 100℃
  • Heating Rate : 5 ℃/s
  • Cooling Rate : 4 ℃/s
Touch Thermal Cycler (Gradient) LTCG-A12

Touch Thermal Cycler (Gradient) LTCG-A12

  • Capacity : 384 well
  • Block Temperature Range : 0 to 100℃
  • Temperature Control Accuracy : ≤ ± 0.1 ℃
  • Ramping Rate Adjustable : 0.1 to 5℃
Touch Thermal Cycler (Gradient) LTCG-A23

Touch Thermal Cycler (Gradient) LTCG-A23

  • Capacity : 3 × 32 × 0.2ml
  • Temperature Range : 0 to 105℃
  • Reaction Volume : 5 to 120μl
  • Max. Heating Rate : 6℃/s

Touch Thermal Cycler (Gradient) LTCG-A24 FAQ's
  • The Thermal Cycler (Gradient) LTCG-A24 accelerates PCR workflows by offering fast heating and cooling rates up to 4.5°C/s and 4°C/s, respectively. Its precise temperature control reduces cycle time without sacrificing accuracy. The integrated gradient function allows simultaneous testing of multiple annealing temperatures, optimizing reaction conditions in a single run and saving valuable lab time. Its user-friendly touchscreen interface simplifies program setup and monitoring. Additionally, the device’s robust construction ensures reliable performance during extended use.

  • The gradient feature of the Thermal Cycler (Gradient) LTCG-A24 generates a range of temperatures across the block, enabling researchers to identify the best annealing temperature for primers and probes. This is critical during assay development and troubleshooting, ensuring higher specificity, reduced non-specific amplification, and improved reproducibility in PCR experiments. It allows simultaneous optimization of multiple samples, saving time and reagents. The real-time temperature display further enhances control and accuracy during experiments.

  • Yes, the Thermal Cycler (Gradient) LTCG-A24 is compatible with standard 0.2 mL PCR tubes arranged in a 96-well format. Its stepless adjustable hot lid prevents evaporation across various tube sizes and plates, providing flexibility to process diverse sample types and volumes commonly used in molecular biology and clinical research. The adjustable hot lid ensures uniform pressure and temperature distribution, protecting sample integrity. This versatility makes it ideal for high-throughput applications and varied experimental protocols. Additionally, the instrument’s design supports easy handling and quick setup for routine lab workflows.

  • Labtron’s Thermal Cycler (Gradient) LTCG-A24 incorporates robust security features including user login with password protection and tiered access control. This ensures that only authorized personnel can modify or run protocols, safeguarding sensitive experimental data. Additionally, it offers ample internal memory to securely store more than 100 program files for easy retrieval. These security measures help maintain data integrity and prevent unauthorized changes. The system also allows administrators to manage user permissions efficiently. This makes the device suitable for multi-user laboratory environments where data confidentiality is critical.

  • Beyond PCR, the Thermal Cycler (Gradient) LTCG-A24 offers a rapid constant-temperature incubation mode suitable for enzymatic reactions like digestion, ligation, and ELISA protocols. Its adjustable hot lid and programmable parameters allow flexible adaptation to diverse molecular biology workflows, reducing the need for multiple instruments. This multifunctionality enhances laboratory efficiency and saves valuable bench space. It also supports streamlined workflows by integrating various reaction steps into a single device.

Post your question?

Our experts are here to help!

Touch Thermal Cycler:
Touch Thermal Cycler (Gradient) LTCG-A15, Touch Thermal Cycler (Basic) LTCB-A14, Touch Thermal Cycler (Basic) LTCB-A13, Touch Thermal Cycler (Gradient) LTCG-A10, Touch Thermal Cycler (Gradient) LTCG-A14, Touch Thermal Cycler (Gradient) LTCG-A22, Touch Thermal Cycler (Gradient) LTCG-A12, Touch Thermal Cycler (Gradient) LTCG-A23, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.