Bench top turbidity meter LTM-B12 with microprocessor controlled system, works on 90° scattered light principle to measure water turbidity in nephelometric turbidity unit i.e. NTU. The formazine standard solution of turbidity mentioned in ISO 7027 is used for turbidity analysis. This turbidity meter delivers highly accurate results with better numerical calculations to meet GLP standards.

Request Quote
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Principle method 90° scattered light
Operating temperature 5 to 40°C
Working temperature 5 to 40°C
Light source Infrared-emitting diode (850 nm λ)
Detector Silicon photodiode
Error value ± 6 % (± 2 % F.S)
Zero drift ± 0.5 % F.S.
Reset functions Yes
Memory Stores up to 20 sets data
Dimension 400 × 300 × 250 mm
Weight 2.5 kg
Power batteries DC 1.5 V, 5 AA alkaline batteries
Power supply AC 220 V, 50 Hz
  • Quick and automatic multi-points calibration
  • Back light LCD display with touch keypad
  • Wide measurement range
  • Non- linear data processing and transfer
  • Selectable automatic or manual switch mode
  • High through put stability
  • Auto power off function
  • Easy to operate

Used in water treatment plants, swimming pool, water recycling units, research and quality laboratories of pharmacy, life science, food, and beverage industry.

Accessory No.NameQuantity
1Specimen bottle3 pcs
2400 NTU (Formazine) turbidity standard solution1 bottle
3Power cable1 pc
Accessory No.Name
1USB communication interface

Models of Turbidity Meter

Labtron Turbidity Meter provide measurement of cloudiness or haziness of fluid caused by presence of suspended particles. They consist of light source including laser, for measuring turbidity levels accurately. Their photodetector captures scattered light, converting it into measurable electrical signals for analysis. They feature sample chamber where water samples are placed for turbidity testing. Our Turbidity Meter evaluates water clarity in wastewater treatment, aquaculture, storm water management, recreational water testing.

Portable Turbidity Meter LTM-A14

Portable Turbidity Meter LTM-A14

  • Measuring range (NTU) : 0 to 100,100 to 800
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 6
  • Sample volume : 5 to 10 ml
Bench top Turbidity Meter LTM-B13

Bench top Turbidity Meter LTM-B13

  • Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 5
  • Sample volume : 5 to 10 ml
Portable Turbidity Meter LTM-A18

Portable Turbidity Meter LTM-A18

  • Measuring Range (NTU) : 0 to 1100 NTU
  • Accuracy : ± 2% (0 to 500 NTU) ± 3% (501 to 1100 NTU)
  • Resolution : 0.01 (0 to 100 NTU) 0.1 (100 to 999 NTU) 1 (999 to 1100 NTU)
  • Calibration Standards : 0.02, 10.00, 200, 500, 1000 or user-defined
Bench Top Turbidity Meter LTM-C10
Bench Top Turbidity Meter LTM-C10
  • Measuring Range : 0 to 100, 0 to 200 NTU
  • Minimum Readout Value : 0.01 NTU
  • Calibration Point : 2
  • Sample Volume : 18 to 20 ml
Bench Top Turbidity Meter LTM-C13
Bench Top Turbidity Meter LTM-C13
  • Measuring Range : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000 NTU
  • Minimum Readout Value : 0.01 NTU
  • Calibration Point : 5
  • Sample Volume : 18 to 20 ml
Portable Turbidity Meter LTM-A12

Portable Turbidity Meter LTM-A12

  • Measuring range (NTU) : 0 to 100,100 to 400
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 5
  • Sample volume : 5 to 10 ml
Bench Top Turbidity Meter LTM-C15

Bench Top Turbidity Meter LTM-C15

  • Measuring Range : 0 to 10, 0 to 100 NTU
  • Minimum Readout Value : 0.001 NTU
  • Calibration Point : 2
  • Sample Volume : 18 to 20 ml
Benchtop Turbidity Meter LTM-B15

Benchtop Turbidity Meter LTM-B15

  • Measuring range (NTU) : 0.000 to 20.00, 20.01 to 200.0, 200 to 2000, 2001 to 4000
  • Minimum readout value (NTU) : 0.001
  • Calibration point : 1 to 8
  • Sample volume : 20 to 30 ml
Bench top Turbidity Meter LTM-B12 FAQ's
  • Labtron Bench Top Turbidity Meter is widely used in industries that require precise water quality testing, such as water treatment plants, swimming pools, and water recycling units. It is also indispensable in research and quality control laboratories for pharmaceutical, life sciences, food, and beverage sectors. The meter’s broad measurement range of 0 to 50, 0 to 100, 0 to 200, 0 to 400 NTU makes it adaptable for a variety of turbidity levels, from very clear water to highly turbid samples. This versatility supports quality monitoring and regulatory compliance across multiple industries.

  • The Bench Top Turbidity Meter utilizes a 90° scattered light principle with a silicon photodiode detector, ensuring high accuracy regardless of the sample’s turbidity level. It is capable of handling everything from low turbidity water to highly turbid industrial samples with a selection of calibration points and a wide measurement range. This flexibility allows operators to quickly switch between different testing applications without compromising on precision.

  • Our Bench Top Turbidity Meter features a backlit LCD and a responsive touch keypad that makes navigation straightforward for both experienced and new users. The meter's selectable automatic or manual measurement modes provide flexibility in operation, allowing users to choose the most appropriate method for their testing conditions. Additionally, the auto power-off function helps conserve energy, making it easy to use in both laboratory and field settings.

  • The Bench Top Turbidity Meter can store up to 20 sets of measurement data, allowing users to keep a log of results for future reference or reporting. Its non-linear data processing ensures that readings are adjusted correctly based on the turbidity level, providing consistent and accurate results. This is especially important for research labs and quality control processes where historical data is critical for analysis. The meter’s quick multi-point calibration ensures that it remains accurate over time.

  • Yes, Labtron's Bench Top Turbidity Meter is equipped with features designed for high-throughput testing, including quick multi-point calibration and a stable measurement system that ensures rapid and reliable results. The wide measurement range covers both low and high turbidity, making it efficient for a variety of testing conditions. It is particularly useful in settings such as water treatment plants or pharmaceutical labs where multiple tests need to be completed efficiently without compromising accuracy.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.