Labtron Turbidity Meter provide measurement of cloudiness or haziness of fluid caused by presence of suspended particles. They consist of light source including laser, for measuring turbidity levels accurately. Their photodetector captures scattered light, converting it into measurable electrical signals for analysis. They feature sample chamber where water samples are placed for turbidity testing. Our Turbidity Meter evaluates water clarity in wastewater treatment, aquaculture, storm water management, recreational water testing.
Measuring range (NTU): 0 to 200
Minimum readout value (NTU): 0.1
Calibration point: Nil
Sample volume: 5 to 10 ml
Measuring range (NTU): 0 to 100,0 to 200
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 4
Sample volume: 5 to 10 ml
Measuring range (NTU): 0 to 100,100 to 400
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 5
Sample volume: 5 to 10 ml
Measuring range (NTU): 0 to 100,100 to 500
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 6
Sample volume: 5 to 10 ml
Measuring range (NTU): 0 to 100,100 to 800
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 6
Sample volume: 5 to 10 ml
Measuring range (NTU): 0 to 100, 100 to 1000
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 7
Sample volume: 5 to 10 ml
Light Source: LED 860nm
Reading Display: LCD
Measuring Mode: NTU, FTU, EBC, ASBC
Measuring Range: 0.000 to 20.00 NTU20.01 to 200.0 NTU200.1 to 1000 NTU
Measuring Range (NTU): 0 to 1000 NTU
Accuracy: ±0.3 NTU or ±8% NTU
Repeatability:
Calibration Point: 8
Measuring Range (NTU): 0 to 1100 NTU
Accuracy: ± 2% (0 to 500 NTU) ± 3% (501 to 1100 NTU)
Resolution: 0.01 (0 to 100 NTU) 0.1 (100 to 999 NTU) 1 (999 to 1100 NTU)
Calibration Standards: 0.02, 10.00, 200, 500, 1000 or user-defined
Measurement Method: 90° Scattered Light
Minimum Value: 0.1 NTU
Measuring Range: 0 to 200 NTU
Calibration Point: 2
Measuring Method: 90° scattering method
Measuring Range: 0 to 200 NTU
Colorimetric Method: Tube colorimetric
Accuracy: Up to 5%
Measuring range (NTU): 0 to 100
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 1
Sample volume: 5 to 10 ml
Principle: 90° scattered light
Minimum Read: 0.01 NTU, 0.1 NTU
Measurement Range: 0 to 100 NTU, 0 to 200 NTU
Calibration Points: 4
Measuring range (NTU): 0 to 50, 0 to 100, 0 to 200, 0 to 400
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 4
Sample volume: 5 to 10 ml
Measuring range (NTU): 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 5
Sample volume: 5 to 10 ml
Measuring range (NTU): 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 6
Sample volume: 5 to 10 ml
Measuring range (NTU): 0.000 to 20.00, 20.01 to 200.0, 200 to 2000, 2001 to 4000
Minimum readout value (NTU): 0.001
Calibration point: 1 to 8
Sample volume: 20 to 30 ml
Measuring Method: 90° scattering method
Measuring Range: 0 to 500 NTU
Colorimetric Method: Tube colorimetric
Accuracy: Up to 5%
Measuring Range: 0 to 100, 0 to 200 NTU
Minimum Readout Value: 0.01 NTU
Calibration Point: 2
Sample Volume: 18 to 20 ml
Measuring Range: 0 to 100, 0 to 200, 0 to 500 NTU
Minimum Readout Value: 0.01 NTU
Calibration Point: 3
Sample Volume: 18 to 20 ml
Measuring Range: 0 to 10, 0 to 100, 0 to 200, 0 to 500 NTU
Minimum Readout Value: 0.01 NTU
Calibration Point: 4
Sample Volume: 18 to 20 ml
Measuring Range: 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000 NTU
Minimum Readout Value: 0.01 NTU
Calibration Point: 5
Sample Volume: 18 to 20 ml
Measuring range (NTU): 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU): 0.001
Calibration point: 5
Sample volume: 18 to 20 ml
Measuring Range: 0 to 10, 0 to 100 NTU
Minimum Readout Value: 0.001 NTU
Calibration Point: 2
Sample Volume: 18 to 20 ml