Request A Quote
Bench Top Turbidity Meter LTM-C11

Bench Top Turbidity Meter LTM-C11

Bench top turbidity meter LTM-C11 measures turbidity in the range of 0 to 100, 0 to 200, and 0 to 500 NTU with a minimum readout value of 0.01 NTU. This device delivers high-accuracy results with enhanced numerical calculations. The meter works on the 90° scattered light principle for reliable turbidity analysis. It ensures high throughput stability for reliable performance. Our benchtop turbidity meter is designed for accurate water turbidity measurement.

Request Quote
Measuring Range 0 to 100, 0 to 200, 0 to 500 NTU
Minimum Readout Value 0.01 NTU
Calibration Point 3
Sample Volume 18 to 20 ml
Operating Temperature Room Temperature
Working Temperature Room Temperature
Light Source Infrared-emitting diode (850 nm λ)
Detector Silicon photodiode
Error Value (F.S) ±2%, ±3%, ±5%
Zero Drift (F.S) ± 0.5% (0.02 NTU)
Reset Functions No
Memory Nil
Output RS232 data communication interface
Power Batteries DC 1.5 V, 5 AA alkaline batteries
Power Supply AC 220 V, 50 Hz
Dimension 415 × 375 × 200 mm
Weight 4 kg
  • Backlit LCD display

  • Auto power-off function

  • Microprocessor-controlled

  • Built-in printer

  • Simple operation

Bench top turbidity meter LTM-C11 is widely used in water treatment plants, swimming pools, and water recycling units to ensure water quality. It is an essential tool in research and quality testing laboratories of pharmaceutical, life science, food, and beverage industries.

Accessory No.NameQuantity
1Specimen bottle3 pcs
2400 NTU (Formazine) turbidity standard solution1 bottle
3Power cable1 pc

Models of Turbidity Meter

Labtron Turbidity Meter provide measurement of cloudiness or haziness of fluid caused by presence of suspended particles. They consist of light source including laser, for measuring turbidity levels accurately. Their photodetector captures scattered light, converting it into measurable electrical signals for analysis. They feature sample chamber where water samples are placed for turbidity testing. Our Turbidity Meter evaluates water clarity in wastewater treatment, aquaculture, storm water management, recreational water testing.

Bench Top Turbidity Meter LTM-C15

Bench Top Turbidity Meter LTM-C15

  • Measuring Range : 0 to 10, 0 to 100 NTU
  • Minimum Readout Value : 0.001 NTU
  • Calibration Point : 2
  • Sample Volume : 18 to 20 ml
Benchtop Turbidity Meter LTM-B16

Benchtop Turbidity Meter LTM-B16

  • Measuring Method : 90° scattering method
  • Measuring Range : 0 to 500 NTU
  • Colorimetric Method : Tube colorimetric
  • Accuracy : Up to 5%
Portable Turbidity Meter LTM-A14

Portable Turbidity Meter LTM-A14

  • Measuring range (NTU) : 0 to 100,100 to 800
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 6
  • Sample volume : 5 to 10 ml
Bench Top Turbidity Meter LTM-C12
Bench Top Turbidity Meter LTM-C12
  • Measuring Range : 0 to 10, 0 to 100, 0 to 200, 0 to 500 NTU
  • Minimum Readout Value : 0.01 NTU
  • Calibration Point : 4
  • Sample Volume : 18 to 20 ml
Bench Top Turbidity Meter LTM-C13
Bench Top Turbidity Meter LTM-C13
  • Measuring Range : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000 NTU
  • Minimum Readout Value : 0.01 NTU
  • Calibration Point : 5
  • Sample Volume : 18 to 20 ml
Portable Turbidity Meter LTM-A18

Portable Turbidity Meter LTM-A18

  • Measuring Range (NTU) : 0 to 1100 NTU
  • Accuracy : ± 2% (0 to 500 NTU) ± 3% (501 to 1100 NTU)
  • Resolution : 0.01 (0 to 100 NTU) 0.1 (100 to 999 NTU) 1 (999 to 1100 NTU)
  • Calibration Standards : 0.02, 10.00, 200, 500, 1000 or user-defined
Benchtop Turbidity Meter LTM-B15

Benchtop Turbidity Meter LTM-B15

  • Measuring range (NTU) : 0.000 to 20.00, 20.01 to 200.0, 200 to 2000, 2001 to 4000
  • Minimum readout value (NTU) : 0.001
  • Calibration point : 1 to 8
  • Sample volume : 20 to 30 ml
Portable Turbidity Meter LTM-A11

Portable Turbidity Meter LTM-A11

  • Measuring range (NTU) : 0 to 100,0 to 200
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 4
  • Sample volume : 5 to 10 ml

Turbidity Meter:
Bench Top Turbidity Meter LTM-C15, Benchtop Turbidity Meter LTM-B16, Portable Turbidity Meter LTM-A14, Bench Top Turbidity Meter LTM-C12, Bench Top Turbidity Meter LTM-C13, Portable Turbidity Meter LTM-A18, Benchtop Turbidity Meter LTM-B15, Portable Turbidity Meter LTM-A11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.