Portable Turbidity Meter LTM-A15

Portable Turbidity Meter LTM-A15

Portable Turbidity meter LTM-A15 with microprocessor controlled system, utilizes 90° scattered light principle to measure water turbidity in nephelometric turbidity unit i.e. NTU. The formazine standard solution of turbidity mentioned in ISO 7027 is used for turbidity analysis. Portable meter, used in field and lab scale analysis, delivers highly accurate results as per the GLP standards.

Request Quote
Measuring range (NTU) 0 to 100, 100 to 1000
Minimum readout value (NTU) 0.01, 0.1
Calibration point 7
Sample volume 5 to 10 ml
Principle method 90° scattered light
Operating temperature 5 to 40°C
Working temperature 5 to 40°C
Light source Infrared-emitting diode (850 nm λ)
Detector Silicon photodiode
Error value ± 6 % (± 2 % F.S)
Zero drift ± 0.5 % F.S.
Reset functions Yes
Memory Stores up to 20 sets data
Dimension 370 × 260 × 150 mm
Weight 1.5 kg
Power batteries DC 1.5 V, 5 AA alkaline batteries
Power supply AC 220 V, 50 Hz
  • Quick and automatic multi-points calibration
  • LCD display with touch keypad
  • Non- linear data processing and transfer
  • Selectable automatic or manual switch mode
  • High through put stability
  • Auto shut down system
  • Easy to use
  • Standard carrying case for field analysis

Used to test turbidity of water across water testing plants, water recycling units, and food and beverage units as a quality and research parameter.

Accessory No.NameQuantity
1Specimen bottle3 pcs
2400 NTU (Formazine) turbidity standard solution1 bottle
3Power cable1 pc
4Carrying box1 pc
Accessory No.Name
1USB communication interface

Models of Turbidity Meter

Labtron Turbidity Meter provide measurement of cloudiness or haziness of fluid caused by presence of suspended particles. They consist of light source including laser, for measuring turbidity levels accurately. Their photodetector captures scattered light, converting it into measurable electrical signals for analysis. They feature sample chamber where water samples are placed for turbidity testing. Our Turbidity Meter evaluates water clarity in wastewater treatment, aquaculture, storm water management, recreational water testing.

Portable Turbidity Meter LTM-A11

Portable Turbidity Meter LTM-A11

  • Measuring range (NTU) : 0 to 100,0 to 200
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 4
  • Sample volume : 5 to 10 ml
Bench Top Turbidity Meter LTM-B11

Bench Top Turbidity Meter LTM-B11

  • Principle : 90° scattered light
  • Minimum Read : 0.01 NTU, 0.1 NTU
  • Measurement Range : 0 to 100 NTU, 0 to 200 NTU
  • Calibration Points : 4
Portable Turbidity Meter LTM-A12

Portable Turbidity Meter LTM-A12

  • Measuring range (NTU) : 0 to 100,100 to 400
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 5
  • Sample volume : 5 to 10 ml
Portable Turbidity Meter LTM-A19
Portable Turbidity Meter LTM-A19
  • Measurement Method : 90° Scattered Light
  • Minimum Value : 0.1 NTU
  • Measuring Range : 0 to 200 NTU
  • Calibration Point : 2
Portable Turbidity Meter LTM-A17
Portable Turbidity Meter LTM-A17
  • Measuring Range (NTU) : 0 to 1000 NTU
  • Accuracy : ±0.3 NTU or ±8% NTU
  • Repeatability :
  • Calibration Point : 8
Bench Top Turbidity Meter LTM-C13

Bench Top Turbidity Meter LTM-C13

  • Measuring Range : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000 NTU
  • Minimum Readout Value : 0.01 NTU
  • Calibration Point : 5
  • Sample Volume : 18 to 20 ml
Portable Turbidity Meter LTM-A14

Portable Turbidity Meter LTM-A14

  • Measuring range (NTU) : 0 to 100,100 to 800
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 6
  • Sample volume : 5 to 10 ml
Portable Turbidity Meter LTM-A13

Portable Turbidity Meter LTM-A13

  • Measuring range (NTU) : 0 to 100,100 to 500
  • Minimum readout value (NTU) : 0.01, 0.1
  • Calibration point : 6
  • Sample volume : 5 to 10 ml

Portable Turbidity Meter LTM-A15 FAQ's
  • Labtron Portable Turbidity Meter supports broad measuring range of 0 to 100 and 100 to1000 NTU, making it ideal for testing both clear and highly turbid water. This makes it particularly useful in industrial settings like wastewater treatment or during stormwater runoff analysis. Our meter's precise optical components and robust calibration ensure accurate readings even at higher turbidity levels. This wide range extends its applicability to more demanding water quality testing tasks.

  • Our Portable Turbidity Meter complies with Good Laboratory Practice (GLP) standards, making it reliable for regulatory and research-based environments. It uses the ISO 7027 formazine calibration standard and offers a seven-point calibration system for increased accuracy. Its non-linear data processing provides reliable output across a range of turbidity values. These features ensure results are consistent, traceable, and defensible in audit scenarios.

  • Yes, the Portable Turbidity Meter is ideal for remote water monitoring due to its ability to run on 5 AA alkaline batteries. It also includes an AC power option for lab use, allowing seamless switching between environments. Its lightweight design and standard carrying case make it highly portable. This versatility makes it dependable for field researchers and technicians operating in less accessible locations.

  • Labtron's Portable Turbidity Meter stores up to 20 sets of readings, allowing users to log multiple tests without immediate data transfer. This is particularly useful during extended fieldwork or batch testing processes. Stored data can be used for trend analysis or record-keeping purposes. The memory function helps maintain workflow continuity without manual logging.

  • The Portable Turbidity Meter is easy to navigate with an intuitive LCD and touch keypad, even for first-time users. Our meter's selectable automatic or manual measurement mode gives flexibility based on user preference and experience level. The auto shut-down feature adds convenience while preserving battery life. These features minimize the learning curve and make it an ideal training tool for new technicians.

Post your question?

Our experts are here to help!

Turbidity Meter:
Portable Turbidity Meter LTM-A11, Bench Top Turbidity Meter LTM-B11, Portable Turbidity Meter LTM-A12, Portable Turbidity Meter LTM-A19, Portable Turbidity Meter LTM-A17, Bench Top Turbidity Meter LTM-C13, Portable Turbidity Meter LTM-A14, Portable Turbidity Meter LTM-A13, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.