| Source | Tap water |
| Conductivity | < 2000 us/cm |
| Hardness | < 450 ppm as CaCO3 |
| Water Temperature | 5 ℃ to 40 ℃ |
| Water Pressure | 0.05 to 0.5 MPa |
| Class I Resistivity (25 ºC) | 18.2 MΩ.cm |
| Class I Water Conductivity (25 ºC) | 0.055 us/cm |
| Class I Water Total Organic Carbon Level | 1 to 5 ppb |
| Class I Particulate Matter | < 1 pc/ml |
| Manual Dispense Flow Rate | 1.5 to 2.0 L/min |
| Automatic Dispense Volume | 100-25000 ml |
| Electrical Voltage | 110 V/220 V±10% |
| Electrical Frequency | 50 HZ/60 HZ |
| External Dimension (Main Units) | 315 × 520 × 560 mm |
| External Dimension (Water Tank) | 380 × 380 × 595 mm |
| Net Weight (Main Units) | 26 Kg |
| Net Weight (Water Tank) | 7 Kg |
Flexible Water Dispensing
Adjustable height and direction
Removable dispensing pistol
Lower energy consumption
Reduced maintenance costs
Our Ultrapure Water System is suited for advanced laboratory applications including molecular biology, electrochemistry, electrophoresis, and ultra-trace analysis, delivering consistently high-purity water for accurate and contamination-free results.
Pretreatment module
High pressure pump
Reverse osmosis
UV Lamp
Ultra-purification cartridge
Microfiltration cartridge
EDI Module
Point-of-use filter
Storage tank 30L
Air filter net for tank
UV-lamp sterilizer for water tank
Remote water dispenser
Pretreatment module
Purification cartridge dual column
Ultra-purification cartridge dual column
Ultra-purification cartridge single column
Point-of-use filter
Point-of-use bio filter
30L multifunctional water tank with integrated UV lamp & air vent
60L multifunctional water tank integrated UV lamp & air vent
Strengthened pretreatment module
Micro filter
24V UV sterilization lamp for water tank
254/185nm dual wavelength UV lamp
100G Reverse osmosis module
200G Reverse osmosis module
Download catalog for
Ultrapure Water System LUWS-E10 Catalog
Labtron Ultrapure Water System feature advanced multi-stage filtration processes, ensuringthe removal of all contaminants. They are designed for efficient water delivery and high flowrates. Our system are energy efficient, providing consistent reliability. They are equippedwith a touch-screen panel and real-time alerts for easy operation. They produce Type Iultrapure water, ideal for critical applications such as molecular biology, cell culture, andanalytical chemistry.








The Ultrapure Water System LUWS-E10 is designed to operate with pretreated feed water, typically purified by reverse osmosis or deionized systems. The system accepts feed water with specific conductivity and hardness levels that fall within recommended operating ranges to maintain the longevity of its components. It is not intended for direct tap water use unless a suitable pretreatment system is installed. Inlet water specifications typically include parameters such as pH range, temperature, and microbial content, which must be controlled for optimal system performance. Proper pre-filtration and pretreatment ensure that the internal filters and UV units’ function effectively. Users should refer to the system manual for exact feed water quality requirements.
Yes, the Ultrapure Water System LUWS-E10 is highly suitable for pharmaceutical, clinical, and biomedical laboratories that require ultrapure water for critical tasks. It delivers water free from organic and inorganic contaminants, ensuring accurate results in clinical diagnostics and pharmaceutical formulations. The system supports applications such as reagent preparation, cell culture, endotoxin testing, and cleaning of labware used in regulated environments. It complies with standards for water purity and is often used in facilities that follow GMP or GLP guidelines. Its automated operation, purity monitoring, and data logging features help maintain compliance and traceability. This makes it a reliable choice for laboratories that demand both purity and documentation.
The Ultrapure Water System LUWS-E10 incorporates dual-wavelength UV lamps (typically 185/254 nm) for oxidation and sterilization. UV at 254 nm inactivates microorganisms such as bacteria, viruses, and fungi, ensuring biological safety. Meanwhile, 185 nm UV oxidizes trace organic compounds, reducing TOC levels and improving overall purity. This dual action is crucial for applications involving nucleic acids, enzymes, and protein work where contamination must be strictly controlled. UV lamps operate continuously and require minimal maintenance. Their effectiveness is monitored by the system, which alerts users when replacement is needed.
Yes, the Ultrapure Water System LUWS-E10 is well-suited for direct connection to sensitive laboratory instruments such as HPLC systems, analysers, and clinical chemistry equipment. It delivers ultrapure water with low TOC and high resistivity, ensuring the absence of contaminants that may interfere with detection or analysis. The stable water quality helps minimize background noise and extend the life of instrument components. The system may include dedicated output ports or optional connection kits for instrument feed lines. Flow control mechanisms ensure steady water delivery without pressure fluctuations. This integration enhances convenience and reduces the need for manual water handling in analytical workflows.
The Ultrapure Water System LUWS-E10 is engineered to deliver ultrapure water with resistivity up to 18.2 M?·cm and TOC levels ?5 ppb, meeting ASTM Type I standards. It utilizes advanced purification technologies like reverse osmosis, UV oxidation, and electrodeionization to remove organic, inorganic, and microbial impurities. A 0.22 ?m final filter at the point of use ensures particle and bacterial retention before dispensing. Real-time monitoring of conductivity/resistivity and TOC levels ensures constant quality control. The intelligent microprocessor alerts users immediately if water purity deviates from set parameters. This consistency is essential for reproducible results in high-sensitivity techniques such as PCR, qPCR, and mass spectrometry.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608