Request A Quote
Benchtop Ion Meter For F, LBIM-A11

Benchtop Ion Meter For F, LBIM-A11

Benchtop Ion meter for F, LBIM-A11 comes with (F) fluoride ion selective electrode for fluoride ion concentration measurement. This Ion meter comes with ± 0.5 % F.S. measurement accuracy. The direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.

Benchtop Ion Meter For F, LBIM-A11
Benchtop Ion Meter For F, LBIM-A11
Benchtop Ion Meter For F, LBIM-A11
Request Quote
Ion measurement range F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
mV range (-1999.9) to 1999.9 mV
mV accuracy ± 0.2 mV
mV resolution 0.1 mV
Temperature measurement range 0 to 105 °C, 32 to 221 °F
Temperature accuracy ± 0.5 °C, ± 0.9 °F
Temperature resolution 0.1°C
Temperature compensation 0 to 100 °C, 32 to 212 °F
Compensation mode Manual or automatic
Data hold function Manual or automatic endpoint detection
Reset function Yes
Stability condition Low or high
Calibration due 0 to 31 days
Power off Manual or automatic (10,20,30 minutes)
Memory Stores up to 500 sets of data
Output USB communication interface
Connector BNC
Display LCD (130 × 110 mm)
Power DC 5 V, using AC adapter, AC 220 V / 50 Hz
Dimension 210 × 188 × 60 mm
Packaging Dimension 310 × 260 × 200 mm
Net Weight 1.5 kg
Gross Weight 2.5 kg
  • Large LCD display
  • 2 - 5 points calibration from low to high concentration
  • Direct ion concentration readout for elaborate measurement process
  • Selectable concentration units from ppm, mg / L, mol / L
  • mV measurements to check the performance of ion selective electrode
  • Temperature compensation provides accurate reading over the entire range
  • Stability indicator to show current measurement status
  • Calibration due reminder for regular calibration of the meter
  • Auto hold function to freeze stable reading for better viewing & recording
  • Automatic electrode diagnosis shows the slope of the sensor
  • Reset setting function
  • Expanded memory stores and recalls up to 500 readings
  • Built –in real time clock stamps
  • USB communication interface to transfer stored data to PC

Benchtop Ion meter is used to measure the fluoride ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.

F fluoride Ion selective electrode
Temperature probe
Standard solution (1000 ppm) 
Ionic strength adjuster (30 mL)
USB cable
DC 5 V Power adapter

Ion selective electrode: F range: 0.02 ppm to saturation
Ion standard solutions: 480 mL / bottle
Ionic strength adjuster: 480 mL / bottle
Temperature probe with sensor

Download catalog for
Benchtop Ion Meter For F, LBIM-A11 Catalog

Available Range :

Benchtop Ion Meter For Ag, LBIM-A22 : Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppm Benchtop Ion Meter For Br LBIM-C14 : Br range: 0 to 19990 g/L Benchtop Ion Meter For Br, LBIM-A14 : Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm Benchtop Ion Meter For Ca LBIM-C13 : Ca range: 0 to 19990 g/L Benchtop Ion Meter For Ca, LBIM-A13 : Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm Benchtop Ion Meter For Cd, LBIM-A28 : Cd range: 1×106– 1M, 0.01-11200 ppm Benchtop Ion Meter For Cl LBIM-C12 : Cl range: 0 to 19990 g/L Benchtop Ion Meter For Cl, LBIM-A10 : Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm Benchtop Ion Meter For Cn, LBIM-A21 : Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm Benchtop Ion Meter For Cu LBIM-C18 : Cu range: 0 to 19990 g/L Benchtop Ion Meter For Cu, LBIM-A27 : Cu range: 1×108 - 1M, 0.06-6400 ppm Benchtop Ion Meter For F LBIM-C10 : F range: 0 to 19990 g/L Benchtop Ion Meter For F, LBIM-A11 : F range: 1 × 106M – saturation, 0.02 ppm to saturation Benchtop Ion Meter For I LBIM-C19 : I range: 0 to 19990 g/L Benchtop Ion Meter For I, LBIM-A26 : I range: 1×108- 1M, 0.06 -127000 ppm Benchtop Ion Meter For K LBIM-C16 : K range: 0 to 19990 g/L Benchtop Ion Meter For K, LBIM-A23 : K range: 1×106 - 1M, 0.04 -39000 ppm Benchtop Ion Meter For Na LBIM-C11 : Na range: 0 to 19990 g/L Benchtop Ion Meter For Na, LBIM-A12 : Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm Benchtop Ion Meter For NH LBIM-C17 : NH range: 0 to 19990 g/L Benchtop Ion Meter For NH3 , LBIM-A20 : NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppm Benchtop Ion Meter For NH4, LBIM-A15 : NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm Benchtop Ion Meter For Pb, LBIM-A25 : Pb range: 1×108 – 0.1M, 0.2-20700 ppm Benchtop Ion Meter For S, LBIM-A24 : S range: 1×107 - 1M, 0.003-32100 ppm

Models of Benchtop Ion Meter

Labtron Benchtop Ion Meter offers measurement of specific ions concentration in solution. They operate using electrodes (ISEs), which respond selectively to particular charged species, allowing for accurate and reliable measurements. Their built-in temperature sensors allow for automatic adjustments to readings minimizing interference from surrounding environmental factors. They feature user-friendly interfaces for easy navigation through evaluation settings and calibration processes. Our Benchtop Ion Meter is essential in environmental monitoring, food and beverage analysis, and pharmaceutical research.

Benchtop Ion Meter For K LBIM-C16

Benchtop Ion Meter For K LBIM-C16

  • Ion measurement range : K range: 0 to 19990 g/L
  • Ion measurement accuracy : 0.005
  • Ion measurement resolution : 4 significant digits (expressed in scientific notation)
  • mV range : 1999.9 to 1999.9 mV
Benchtop Ion Meter For Br LBIM-C14

Benchtop Ion Meter For Br LBIM-C14

  • Ion measurement range : Br range: 0 to 19990 g/L
  • Ion measurement accuracy : 0.005
  • Ion measurement Resolution : 4 significant digits (expressed in scientific notation)
  • mV range : 1999.9 to1999.9 mV
Benchtop Ion Meter For Cu LBIM-C18

Benchtop Ion Meter For Cu LBIM-C18

  • Ion measurement range : Cu range: 0 to 19990 g/L
  • Ion measurement accuracy : 0.005
  • Ion measurement resolution : 4 significant digits (expressed in scientific notation)
  • mV range : 1999.9 to 1999.9 mV
Benchtop Ion Meter For Cl, LBIM-A10
Benchtop Ion Meter For Cl, LBIM-A10
  • Ion measurement range : Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
  • Ion measurement accuracy : ± 0.5 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
Benchtop Ion Meter For Cn, LBIM-A21
Benchtop Ion Meter For Cn, LBIM-A21
  • Ion measurement range : Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
Benchtop Ion Meter For NO LBIM-C15

Benchtop Ion Meter For NO LBIM-C15

  • Test Parameters : pH/ISE/Temp. (mV/pX)
  • pH Range : -2.00 to 20.00 pH
  • pH Resolution : 0.1, 0.01 pH
  • pH Accuracy : ±0.01 pH
Benchtop Ion Meter For Cl LBIM-C12

Benchtop Ion Meter For Cl LBIM-C12

  • Ion measurement range : Cl range: 0 to 19990 g/L
  • Ion measurement accuracy : 0.005
  • Ion measurement Resolution : 4 significant digits (expressed in scientific notation)
  • mV range : 1999.9 to1999.9 mV
Benchtop Ion Meter For Cu, LBIM-A27

Benchtop Ion Meter For Cu, LBIM-A27

  • Ion measurement range : Cu range: 1×108 - 1M, 0.06-6400 ppm
  • Ion measurement accuracy : ± 1 % F.S.
  • Resolution : 0.001, 0.01, 0.1, 1
  • Calibration points : 2 to 5 points
Benchtop Ion Meter For F, LBIM-A11 FAQ's
  • Labtron Benchtop Ion meter for F is ideal for analyzing fluoride ion concentration in potable water, distilled water, wastewater, and natural water bodies. It has a wide measurement range, from as low as 0.02 ppm up to saturation, makes it suitable for environmental monitoring, municipal water testing, and industrial applications. The fluoride ion selective electrode ensures precise and reliable results across different water types. This versatility makes it a valuable tool for labs and water treatment facilities.

  • The Benchtop Ion meter for F includes a calibration due reminder that alerts users when the meter needs recalibration, with a setting range from 0 to 31 days. Regular calibration is key for ensuring long-term accuracy, especially in high-frequency testing environments. This feature helps maintain optimal electrode performance. It also promotes reliable data for regulatory or quality control requirements.

  • Labtron's Benchtop Ion meter for F has a large LCD display and a direct ion concentration readout, making results easy to view and interpret. Users can select measurement units in ppm, mg/L, or mol/L, depending on their needs. The interface allows customization of key settings like calibration points and stability conditions. These features simplify the testing process and improve workflow efficiency in the lab.

  • Yes, Our Benchtop Ion meter for F includes a mV measurement mode that helps assess the condition and performance of the fluoride ion selective electrode. The automatic electrode diagnostic function also displays the sensor’s slope, offering insight into its effectiveness. This helps users detect when cleaning or replacement is needed. These functions are essential for maintaining measurement reliability.

  • The Benchtop Ion meter for F offers both manual and automatic temperature compensation from 0 to 100°C. This ensures that the fluoride concentration readings remain accurate across different sample temperatures. The included temperature probe monitors real-time values for precise compensation. This is particularly useful when testing environmental samples where temperature variability is common.

  • Our Benchtop Ion meter for F has memory capacity to store up to 500 data sets with real-time clock stamps for accurate recordkeeping. The stored data can be transferred easily to a computer via the USB communication interface. This is useful for compiling reports or maintaining testing logs. It supports traceability and data management in both research and quality assurance contexts.

  • The Benchtop Ion meter for F has manual and automatic power-off options that can be set to 10, 20, or 30 minutes to reduce energy consumption. It operates on a low-voltage 5V DC power adapter, ensuring stable and safe usage. The reset function allows users to restore the device to factory settings. These features help protect the instrument and support user safety during operation.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.