Biosafety Cabinet Class II A2 LBS2-A50

Biosafety Cabinet Class II A2 LBS2-A50

Biosafety Cabinet Class II A2 LBS2-A50 operates with 70% recirculating and 30% exhaust airflow through a top exhaust. It includes a high-performance blower that ensures stable airflow despite voltage or filter changes. The compact, energy-efficient motor runs quietly and stays cool. A touch screen control panel is conveniently accessible from a seated position. Our Biosafety Cabinet is ideal for lab procedures such as cell culture, tissue engineering, clinical testing, genetic research, and non-toxic chemotherapy preparation.

Biosafety Cabinet Class II A2 LBS2-A50_front view
Biosafety Cabinet Class II A2 LBS2-A50-01
Biosafety Cabinet Class II A2 LBS2-A50-02
Biosafety Cabinet Class II A2 LBS2-A50-03
Request Quote
Tested Opening 180 mm
Maximum Opening 530 mm
Airflow System 70% air recirculation, 30% air exhaust
Average Inflow Velocity 0.50 m/s
Average Downflow Velocity 0.33 m/s
Inflow Airflow Volume 343 m3/h
Downflow Airflow Volume 798 m3/h
Exhaust Airflow Volume 343 m3/h
Filter Specification ULPA > 99.999% efficiency at 0.3 µm
Cleanliness Grade Class 3 (ISO 14644.1)
Display 7 inches touch screen
Sash Glass Type Tempered Glass, UV-proof
Fluorescent Lamp 30W
UV Lamp 3OW
Fluorescent Light Intensity ≥700 lux
Sound Emission ≤65 Db
Colony Count (Cross Contamination Protection) ≤2 CFU/Time
Material External: 18-gauge Electro-galvanized steel with white oven-baked powder-coated finish; Work Surface: 16-gauge Stainless steel
Power Consumption 1500W
Power Supply AC 220, 50/60HZ
Internal Dimension (W × D × H) 1000 × 672 × 630 mm
External Dimension (W × D × H) 1180 × 790 × 2080 mm
Packaging Dimension (W × D × H) 1310 × 950 × 2220 mm
Net Weight 250 Kg
Gross Weight 275 Kg
  • UV Germicidal Lamp

  • Pressure Monitor

  • Glass Sash with Anti-Reflective Coating

  • Noise Reduction Technology

  • Modular Filter System

Our biosafety cabinet is used for safely handling moderate-risk biological agents in microbiology, virology, pharmaceutical aseptic processing, genetic engineering, molecular biology, celli-based assays, forensic labs, allergy research, and vaccine cultivation. 

  • Fluorescent Lamp

  • Ultraviolet Lamp

  • Receptacle

  • Detachable Base Stand

Accessories

Quantity

Gas Valve

1

Vacuum Valve

1

Water Valve

1

Arm Rest

1

I.V. Pole

1

Canopy Connection

1

Biosafety Cabinet Class II A2 LBS2-A50 | Tested Opening: 180 mm | Maximum Opening: 530 mm
Biosafety Cabinet Class II A2 LBS2-A50 | UV Germicidal Lamp | Pressure Monitor

Models of Biosafety Cabinet

Labtron Biosafety Cabinets are incorporated with advanced technology, including ULPA filters and UV indicators. These cabinets ensure advanced protection with built-in interlock functionalities. Our diverse selection encompasses Class I, Class II A2, Class II B2, and more. They provide exceptional airflow control for maintaining sterility and optimizing laboratory conditions. Our biosafety cabinet provides unparalleled durability, featuring two-layer laminated toughened glass.

Biosafety Cabinet Class II B2 LBS2-B23

Biosafety Cabinet Class II B2 LBS2-B23

  • HEPA Filter Efficiency : ≥ 99.995% at 0.3 µm
  • ULPA Filter Efficiency : ≥ 99.999% at 0.12 µm
  • Noise : ≤ 65 DB
  • Inflow Velocity : 0.53 m/s
Biosafety Cabinet Class II A2 LBS2-A24

Biosafety Cabinet Class II A2 LBS2-A24

  • Exhaust Air Volume : 381 m³/h
  • Downflow Volume : 748 m³/h
  • Total Air Volume : 1130 m³/h
  • Noise Level : ≤63 dB(A)
Biosafety Cabinet Class II A2 LBS2-A31

Biosafety Cabinet Class II A2 LBS2-A31

  • External Dimension (W×D×H) : 1087×775×2265 mm
  •  Internal Dimension (W×D×H) : 910×600×660 mm
  •  Work Surface Height : 750 mm
  •  Max Opening : 520 mm (22.5 inch)
Biosafety Cabinet Class II B2 LBS2-B10
Biosafety Cabinet Class II B2 LBS2-B10
  • Tested Opening : 180 mm
  • Maximum Opening : 530 mm
  • Usable Working Area : 0.672 m²
  • Airflow System : 70% air recirculation, 30% air exhaust
Biosafety Cabinet Class I LBS1-A10
Biosafety Cabinet Class I LBS1-A10
  • HEPA filters : 99.995% efficiency at 0.3 µm
  • Noise : ≤ 60 dB
  • UV lamp : Emission of 253.7 nm for efficient sterilization
  • Illuminating lamp : 4W × 1 LED lamp
Biosafety Cabinet Class II A2 LBS2-A23

Biosafety Cabinet Class II A2 LBS2-A23

  • Tested Opening : Safety height of 200 mm (8 inch)
  • Maximum Opening : 550 mm (22 inch)
  • Inflow Velocity : 0.53 ± 0.025 m/s
  • Down Flow Velocity : 0.33 ± 0.025 m/s
Biosafety Cabinet Class II B2 LBS2-B21

Biosafety Cabinet Class II B2 LBS2-B21

  • Max Opening : 420 mm (17 inch)
  • Tested Opening : Safety Height 200 mm(8 inch)
  • Inflow Velocity : 0.53 ± 0.025 m/s
  • Down flow Velocity : 0.33 ± 0.025 m/s
Biosafety Cabinet Class II A2 LBS2-A41

Biosafety Cabinet Class II A2 LBS2-A41

  • Tested Opening : Safety Height 200 mm
  • Maximum Opening : 440 mm
  • Airflow System : 70% air recirculation, 30% air exhaust
  • Airflow Velocity Range : 0.3 to 0.6 m/s

Biosafety Cabinet Class II A2 LBS2-A50 FAQ's
  • A Biosafety Cabinet Class II A2 LBS2-A50 is a ventilated laboratory workspace designed to protect users, samples, and the environment from biohazards. It works by maintaining a 70% recirculation and 30% exhaust airflow, filtering air through HEPA filters before re-entering the work zone or being released. The cabinet provides an ISO Class 5 clean air environment, minimizing contamination during sensitive lab procedures. It creates a protective barrier using inward airflow and filtered downward laminar air. Contaminated air is filtered before it is recirculated or exhausted. This makes it suitable for handling low to moderate risk biological agents. It is commonly used in microbiology, tissue culture, and pharmaceutical labs.

  • The airflow system uses vertical laminar flow combined with a front air barrier to protect the operator. Contaminated air is drawn away from the work zone and passes through ULPA filters that remove 99.99% of particles 0.3 microns or larger. The filtered air is then partly recirculated into the work area and partly exhausted outside or into the building’s HVAC system. This balance prevents harmful agents from escaping the cabinet while maintaining sterility inside. The top exhaust design directs contaminated air away from personnel and lab spaces. Continuous airflow monitoring ensures that protection remains consistent during operation.

  • This Biosafety Cabinet Class II A2 LBS2-A50 includes a front sash with safety locks to prevent accidental exposure and maintain proper airflow. It is equipped with audible and visual alarms that alert users if airflow falls below safe levels or if the sash is improperly positioned. The built-in UV germicidal lamp allows for effective decontamination of the interior between uses, reducing microbial buildup. Real-time pressure monitoring ensures the cabinet maintains a negative pressure environment to contain contaminants. The cabinet also features an energy-efficient blower motor designed for quiet and stable operation. Together, these features help maintain a safe working environment for both operators and samples.

  • The Biosafety Cabinet Class II A2 LBS2-A50 is equipped with both visual and audible alarms that notify operators of airflow disruptions, filter status, or improper sash position. These alarms help prevent unsafe operating conditions by prompting immediate corrective action. The control panel displays real-time data including airflow velocity and pressure readings for constant monitoring. If the airflow falls below safety thresholds, the system automatically alerts users to avoid exposure risks. Filter clogging or maintenance needs trigger specific warnings to ensure timely service. These features help maintain compliance with biosafety standards and ensure user safety.

  • Yes, the Biosafety Cabinet Class II A2 LBS2-A50 top exhaust design allows for easy integration with a laboratory’s HVAC system for efficient removal of exhaust air. This integration helps maintain negative pressure in the lab and prevents contamination spread. Proper installation ensures that exhausted air is safely discharged or filtered according to local regulations. The cabinet’s design supports connection to ductwork with minimal airflow disruption. This flexibility makes it suitable for new labs as well as retrofit projects. Coordination with HVAC professionals is recommended to optimize system performance.

Post your question?

Our experts are here to help!

Biosafety Cabinet:
Biosafety Cabinet Class II B2 LBS2-B23, Biosafety Cabinet Class II A2 LBS2-A24, Biosafety Cabinet Class II A2 LBS2-A31, Biosafety Cabinet Class II B2 LBS2-B10, Biosafety Cabinet Class I LBS1-A10, Biosafety Cabinet Class II A2 LBS2-A23, Biosafety Cabinet Class II B2 LBS2-B21, Biosafety Cabinet Class II A2 LBS2-A41, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.