Request A Quote
Biosafety Cabinet Class II A2 LBS2-A51

Biosafety Cabinet Class II A2 LBS2-A51

Biosafety Cabinet Class II A2 LBS2-A51 is equipped with a ULPA filter that removes 99.999% of particles ≥0.3 microns. It includes a UV germicidal lamp with a timer for efficient sterilization. The cabinet is made of corrosion-resistant material and has a smooth, easy-to-clean surface. Safety features include waterproofing, overload protection, and covered electrical outlets with a slow-closing mechanism. Our Biosafety Cabinet is suitable for microbiology labs, pharmaceutical industries, research centers, and diagnostic facilities. 

Request Quote
Tested Opening 180 mm
Maximum Opening 530 mm
Airflow System 70% air recirculation, 30% air exhaust
Average Inflow Velocity 0.50 m/s
Average Downflow Velocity 0.33 m/s
Inflow Airflow Volume 446 m3/h
Downflow Airflow Volume 1038 m3/h
Exhaust Airflow Volume 446 m3/h
Filter Specification ULPA > 99.999% efficiency at 0.3 µm
Cleanliness Grade Class 3 (ISO 14644.1)
Display 7 inches touch screen
Sash Glass Type Tempered Glass, UV-proof
Fluorescent Lamp 30W
UV Lamp 3OW
Fluorescent Light Intensity ≥700 lux
Sound Emission ≤65 Db
Colony Count (Cross Contamination Protection) ≤2 CFU/Time
Material External: 18-gauge Electro-galvanized steel with white oven-baked powder-coated finish; Work Surface: 16-gauge Stainless steel
Power Consumption 1500W
Power Supply AC 220, 50/60HZ
Internal Dimension (W × D × H) 1300 × 672 × 630 mm
External Dimension (W × D × H) 1480 × 790 × 2080 mm
Packaging Dimension (W × D × H) 1610 × 950 × 2220 mm
Net Weight 270 Kg
Gross Weight 300 Kg
  • High-Performance Blower

  • Smart Energy Saving Mode

  • Adjustable Tempered Glass Sash

  • Easy Filter Replacement

  • Low Vibration Design

Our biosafety cabinets are essential in research, clinical, pharmaceutical, veterinary, agricultural, and academic fields, offering contamination control and user protection during the safe handling of samples, cultures, and infectious materials.

  • Fluorescent Lamp

  • Ultraviolet Lamp

  • Receptacle

  • Detachable Base Stand

Accessories

Quantity

Gas Valve

1

Vacuum Valve

1

Water Valve

1

Arm Rest

1

I.V. Pole

1

Canopy Connection

1

Biosafety Cabinet Class II A2 LBS2-A51 | Tested Opening: 180 mm | Maximum Opening: 530 mm
Biosafety Cabinet Class II A2 LBS2-A51 | High-Performance Blower | Smart Energy Saving Mode

Models of Biosafety Cabinet

Labtron Biosafety Cabinets are incorporated with advanced technology, including ULPA filters and UV indicators. These cabinets ensure advanced protection with built-in interlock functionalities. Our diverse selection encompasses Class I, Class II A2, Class II B2, and more. They provide exceptional airflow control for maintaining sterility and optimizing laboratory conditions. Our biosafety cabinet provides unparalleled durability, featuring two-layer laminated toughened glass.

Biosafety Cabinet Class II A2 LBS2-A21

Biosafety Cabinet Class II A2 LBS2-A21

  • Tested Opening : Safety height of 200 mm (8 inch)
  • Maximum Opening : 420 mm (17 inch)
  • Inflow Velocity : 0.53 ± 0.025 m/s
  • Down Flow Velocity : 0.33 ± 0.025 m/s
Biosafety Cabinet Class II B2 LBS2-B12

Biosafety Cabinet Class II B2 LBS2-B12

  • Tested Opening : 180 mm
  • Maximum Opening : 530 mm
  • Usable Working Area : 1.0752 m²
  • Airflow System : 70% air recirculation, 30% air exhaust
Biosafety Cabinet Class II A2 LBS2-A20

Biosafety Cabinet Class II A2 LBS2-A20

  • Tested Opening : Safety height of 200 mm (8 inch)
  • Maximum Opening : 420 mm (17 inch)
  • Inflow Velocity : 0.53 ± 0.025 m/s
  • Down Flow Velocity : 0.33 ± 0.025 m/s
Biosafety Cabinet Class II B2 LBS2-B23
Biosafety Cabinet Class II B2 LBS2-B23
  • HEPA Filter Efficiency : ≥ 99.995% at 0.3 µm
  • ULPA Filter Efficiency : ≥ 99.999% at 0.12 µm
  • Noise : ≤ 65 DB
  • Inflow Velocity : 0.53 m/s
Biosafety Cabinet Class I LBS1-A10
Biosafety Cabinet Class I LBS1-A10
  • HEPA filters : 99.995% efficiency at 0.3 µm
  • Noise : ≤ 60 dB
  • UV lamp : Emission of 253.7 nm for efficient sterilization
  • Illuminating lamp : 4W × 1 LED lamp
Biosafety Cabinet Class II A2 LBS2-A23

Biosafety Cabinet Class II A2 LBS2-A23

  • Tested Opening : Safety height of 200 mm (8 inch)
  • Maximum Opening : 550 mm (22 inch)
  • Inflow Velocity : 0.53 ± 0.025 m/s
  • Down Flow Velocity : 0.33 ± 0.025 m/s
Biosafety Cabinet Class II A2 LBS2-A40

Biosafety Cabinet Class II A2 LBS2-A40

  • Work Surface Height : 750 mm
  • Max Opening : 500 mm
  • Tested Opening : 200 mm
  • Airflow Volume : Inflow: 490 m³/h (289 cfm) Downflow: 65%: 910 m³/h (536 cfm) Exhaust: 35%: 490 m³/h (289 cfm)
Biosafety Cabinet Class II A2 LBS2-A33

Biosafety Cabinet Class II A2 LBS2-A33

  • External Dimension (W×D×H) : 1873×775×2240 mm
  •  Internal Dimension (W×D×H) : 1700×600×660 mm
  •  Work Surface Height : 782 mm
  •  Max Opening : 470 mm (22 inch)

Biosafety Cabinet Class II A2 LBS2-A51 FAQ's
  • The Biosafety Cabinet Class II A2 LBS2-A51 uses a 70% recirculating airflow and 30% exhaust airflow design. This configuration optimizes both user and product protection by balancing clean air recirculation and exhaust of potentially contaminated air. The airflow passes through high-efficiency ULPA filters that remove 99.9995% of particles down to 0.12 microns. This ensures a sterile environment inside the work area while preventing contaminants from escaping. The design also promotes energy efficiency by minimizing exhaust volume. Overall, it provides a safe and stable working environment for biological samples.

  • Yes, the Biosafety Cabinet Class II A2 LBS2-A51 features a motorized front window that can be adjusted vertically. This allows users to set the sash height for optimal comfort and ergonomic working conditions. The slow self-closing function enhances safety by preventing sudden sash movements. Adjustability also helps maintain the proper airflow barrier between the user and the work zone. The window is made of tempered glass for durability and clear visibility. This design improves user experience without compromising safety.

  • The Biosafety Cabinet Class II A2 LBS2-A51 is equipped with an integrated UV germicidal lamp that helps sterilize the interior work surface. This lamp emits ultraviolet light that effectively kills bacteria, viruses, and other microorganisms. The lamp is usually controlled by a timer to ensure safe and optimal sterilization cycles. It should only be operated when the cabinet is not in use to avoid exposure hazards. Regular cleaning of the lamp and interior surfaces is recommended to maintain effectiveness. Proper use of the UV lamp helps reduce contamination risks within the cabinet.

  • The filters should be replaced based on the manufacturer’s recommendations, typically every 1 to 3 years depending on usage. Frequent use with hazardous materials may require more frequent replacement to maintain efficiency. The cabinet’s digital display and alarms will also notify users when filter performance declines. Regular inspections during preventive maintenance help determine the right timing for replacement. Timely filter changes are essential to ensure continued protection for both the user and the samples. Neglecting filter replacement can lead to contamination and compromised biosafety.

  • Filter replacement must be performed by trained personnel following strict biosafety protocols. Before replacement, the cabinet should be decontaminated using chemical disinfectants or sterilization methods. The work area should be prepared to contain any particles that might be released during filter removal. Protective equipment such as gloves, masks, and gowns must be worn during the procedure. After removing the old filters, the new filters should be installed carefully to ensure airtight sealing. Finally, the cabinet must be recertified to verify that the filters are functioning correctly.

Post your question?

Our experts are here to help!

Biosafety Cabinet:
Biosafety Cabinet Class II A2 LBS2-A21, Biosafety Cabinet Class II B2 LBS2-B12, Biosafety Cabinet Class II A2 LBS2-A20, Biosafety Cabinet Class II B2 LBS2-B23, Biosafety Cabinet Class I LBS1-A10, Biosafety Cabinet Class II A2 LBS2-A23, Biosafety Cabinet Class II A2 LBS2-A40, Biosafety Cabinet Class II A2 LBS2-A33, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.