Biosafety Cabinet Class II B2 LBS2-B12 operates with 100% exhaust airflow and a top exhaust direction. It features advanced air purification and a negative pressure design for safety. The cabinet ensures protection for users, the environment, and samples. It is equipped with a security lock to prevent unauthorized or unfamiliar access to the cabinet. Our Biosafety Cabinet is suitable for applications such as cell and tissue culture, blood analysis, medium preparation, and handling toxic chemicals or radionuclides.

Request Quote
Tested Opening 180 mm
Maximum Opening 530 mm
Usable Working Area 1.0752 m²
Airflow System 70% air recirculation, 30% air exhaust
Average Inflow Velocity 0.53 m/s
Average Downflow Velocity 0.35 m/s
Inflow Airflow Volume 1826 m3/h
Downflow Airflow Volume 1277 m3/h
Exhaust Airflow Volume 1826 m3/h
Filter Specification ULPA > 99.999% efficiency at 0.3 µm
Cleanliness Grade Class 3 (ISO 14644.1)
Display 7 inches touch screen
Sash Glass Type Tempered Glass, UV-proof
Fluorescent Lamp 30 W
UV Lamp 3O W
Fluorescent Light Intensity ≥ 700 lux
RMS ≤ 3 µm
Sound Emission ≤ 65 Db
Colony Count (Cross Contamination Protection) ≤ 2 CFU/Time
Material External: 18-gauge Electro-galvanized steel with white oven-baked powder-coated finish; Work Surface: 16-gauge Stainless steel
Power Consumption 1500 W
Power Supply AC 220 ± 10%, 50/60 HZ
Internal Dimension (W × D × H) 1600 × 672 × 630 mm
External Dimension (W × D × H) 1780 × 790 × 2080 mm
Packaging Dimension (W × D × H) 1910 × 950 × 2220 mm
Net Weight 330 Kg
Gross Weight 370 Kg
  • Robust Frame Structure

  • Energy-Saving Mode

  • Advanced Airflow Pattern Design

  • Low Turbulence Airflow System

  • Multi-layered Filtration System

Our Biosafety Cabinet is used in biotech, microbiology, pharma, and clinical research, ensuring a sterile, safe environment for infectious agents, volatile substances, sensitive materials in general and specialized lab tasks.

Accessory Name

Quantity

Fluorescent lamp

2

Ultraviolet lamp

2

Receptacle (Pieces/Power/Current)

1

Detachable Base Stand 

1

Wheels

1

  • Gas Valve

  • Vacuum Valve

  • Water Valve

  • Arm Rest

  • I.V. Pole

  • Canopy Connection

Models of Biosafety Cabinet

Labtron Biosafety Cabinets are incorporated with advanced technology, including ULPA filters and UV indicators. These cabinets ensure advanced protection with built-in interlock functionalities. Our diverse selection encompasses Class I, Class II A2, Class II B2, and more. They provide exceptional airflow control for maintaining sterility and optimizing laboratory conditions. Our biosafety cabinet provides unparalleled durability, featuring two-layer laminated toughened glass.

Biosafety Cabinet Class II A2 LBS2-A30

Biosafety Cabinet Class II A2 LBS2-A30

  • External Dimension (W×D×H) : 1300mm × 750mm × 2250 mm
  •  Internal Dimension (W×D×H) : 1150mm × 600mm × 660mm
  •  Work Surface Height : 750 mm
  •  Max Opening : 420 mm (17 inch)
Biosafety Cabinet Class II B2 LBS2-B23

Biosafety Cabinet Class II B2 LBS2-B23

  • HEPA Filter Efficiency : ≥ 99.995% at 0.3 µm
  • ULPA Filter Efficiency : ≥ 99.999% at 0.12 µm
  • Noise : ≤ 65 DB
  • Inflow Velocity : 0.53 m/s
Biosafety Cabinet Class II B2 LBS2-B22

Biosafety Cabinet Class II B2 LBS2-B22

  • Max Opening : 500 mm (20 inch)
  • Tested Opening : Safety Height 200 mm(8 inch)
  • Inflow Velocity : 0.53 ± 0.025 m/s
  • Down flow Velocity : 0.33 ± 0.025 m/s
Biosafety Cabinet Class II A2 LBS2-A50
Biosafety Cabinet Class II A2 LBS2-A50
  • Tested Opening : 180 mm
  • Maximum Opening : 530 mm
  • Airflow System : 70% air recirculation, 30% air exhaust
  • Average Inflow Velocity : 0.50 m/s
Biosafety Cabinet Class III LBS3-A10
Biosafety Cabinet Class III LBS3-A10
  • Filter : Two-stage HEPA filter
  • HEPA Filter Efficiency : More than or equal to 99.995% efficiency at 0.3 µm
  • Noise : Less than or equal to 65 dB (A)
  • Negative Pressure : More than or equal to 120 Pa
Biosafety Cabinet Class II B2 LBS2-B21

Biosafety Cabinet Class II B2 LBS2-B21

  • Max Opening : 420 mm (17 inch)
  • Tested Opening : Safety Height 200 mm(8 inch)
  • Inflow Velocity : 0.53 ± 0.025 m/s
  • Down flow Velocity : 0.33 ± 0.025 m/s
Biosafety Cabinet Class II A2 LBS2-A51

Biosafety Cabinet Class II A2 LBS2-A51

  • Tested Opening : 180 mm
  • Maximum Opening : 530 mm
  • Airflow System : 70% air recirculation, 30% air exhaust
  • Average Inflow Velocity : 0.50 m/s
Biosafety Cabinet Class II A2 LBS2-A20

Biosafety Cabinet Class II A2 LBS2-A20

  • Tested Opening : Safety height of 200 mm (8 inch)
  • Maximum Opening : 420 mm (17 inch)
  • Inflow Velocity : 0.53 ± 0.025 m/s
  • Down Flow Velocity : 0.33 ± 0.025 m/s

Biosafety Cabinet Class II B2 LBS2-B12 FAQ's
  • Yes, the Biosafety Cabinet Class II B2 LBS2-B12 features a microprocessor-controlled airflow monitoring system that continuously observes and adjusts the airflow rates in real time. This automation maintains stable inflow and downflow speeds to ensure maximum containment and safety. Users do not need to manually adjust the airflow, which reduces the chance of human error. If the airflow deviates from safe parameters, the system triggers alarms to alert the user immediately. This continuous regulation guarantees that the cabinet always operates within optimal safety conditions. The hands-free adjustment improves convenience for lab personnel. It also helps maintain consistent protection during prolonged use.

  • Yes, the Biosafety Cabinet Class II B2 LBS2-B12 is equipped with a multi-layer filtration system that includes HEPA filters for biological hazards and activated carbon filters for chemical vapors. HEPA filters efficiently capture harmful biological particles such as bacteria, viruses, and spores. Activated carbon filters absorb toxic chemical fumes and odors, providing protection from hazardous substances. This combination ensures that both airborne biological and chemical contaminants are safely removed. The cabinet’s 100% exhaust airflow further enhances safety by venting contaminants outside the lab. Such design makes it versatile for various applications involving mixed hazards. It is ideal for laboratories working with diverse hazardous materials.

  • The Biosafety Cabinet Class II B2 LBS2-B12 includes a modular filter system that allows quick and easy replacement of filters without specialized tools. It has built-in alarms that notify users when filter integrity is compromised, ensuring timely maintenance. An intelligent self-diagnostic system detects faults early, helping to prevent equipment failure or safety breaches. The seamless interior design minimizes contamination buildup and makes cleaning easier. These features collectively reduce downtime and maintenance effort. Regular alerts and diagnostics help maintain consistent safety and performance standards. This user-friendly design supports efficient lab operations and prolongs the cabinet’s lifespan.

  • The ergonomic design positions controls and displays within easy reach, minimizing awkward movements during operation. It provides a comfortable working height to reduce physical strain and fatigue during extended laboratory procedures. Quiet operation decreases distractions and creates a more pleasant work environment. The cabinet includes bright internal lighting that improves visibility and reduces eye strain. These features collectively enhance user comfort and productivity. By reducing fatigue and discomfort, the design supports safer, more efficient workflows. This focus on ergonomics benefits lab personnel’s well-being during long-term use.

  • Yes, the Biosafety Cabinet Class II B2 LBS2-B12 offers network connectivity options that allow remote monitoring of critical parameters such as airflow rates, filter status, and alarm conditions. Lab managers can access real-time data and operational history from anywhere, improving oversight and management. Data logging capabilities record performance details for compliance reporting and preventive maintenance planning. Remote alerts notify personnel immediately if the cabinet experiences any issues or deviations. This enables quick corrective actions to maintain safety and functionality. Remote monitoring reduces the need for constant physical checks and helps avoid unexpected downtime. It supports modern laboratory management by enhancing control and responsiveness.

Post your question?

Our experts are here to help!

Biosafety Cabinet:
Biosafety Cabinet Class II A2 LBS2-A30, Biosafety Cabinet Class II B2 LBS2-B23, Biosafety Cabinet Class II B2 LBS2-B22, Biosafety Cabinet Class II A2 LBS2-A50, Biosafety Cabinet Class III LBS3-A10, Biosafety Cabinet Class II B2 LBS2-B21, Biosafety Cabinet Class II A2 LBS2-A51, Biosafety Cabinet Class II A2 LBS2-A20, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.