Horizontal Laminar Flow Clean Bench LHCB-B17

Horizontal Laminar Flow Clean Bench LHCB-B17

Horizontal Laminar Flow Clean Bench LHCB-B17 provides an airflow velocity of 1800m³/h to continuously clear contaminants from the work surface, preserving sterile conditions. The clean bench features a turbulence-free laminar stream for unidirectional airflow, continuously sweeps away particles without turbulent mixing. It is equipped with UV sterilization options, reducing the microbial load. Our horizontal laminar flow clean bench offers ultra-thin non-partition filters, providing filtration efficiency that can reach the static level.

Horizontal Laminar Flow Clean Bench LHCB-B17_Front View
Horizontal Laminar Flow Clean Bench LHCB-B17_Side  View
Horizontal Laminar Flow Clean Bench LHCB-B17_Side  View
Request Quote
External Dimension (W× L × H) 1200 mm × 820 mm × 1500 mm
Work Area Size (W× L × H) 1130 mm × 600 mm × 600 mm
Illumination >300 ux
Airflow Velocity 1800 m³/h
Average Wind Speed 0.3 to 0.6 m/s
LED Standard 30 × 1
Cleanliness Grade Level 100
Noise Level ≤65
Filtration Efficiency (% at 0.3µm) 99.99
Material Cold-rolled steel plate with powder-coated or sand-ground stainless steel
Power Supply 220/50 V/Hz
Power Consumption 700 W
  • Corrosion‑Resistant Stainless Surface

  • Durable Powder‑Coated Structure

  •  Integrated LED Illumination

  • Adjustable Fan Speed

  • Real‑Time Airflow Alarm

Horizontal Laminar Flow Clean Bench LHCB-B17 is an enclosed bench device with rear-mounted HEPA filtration that sweeps clean, unidirectional air. It is applied in medical and health, optics, optoelectronics, microbiological testing and food sectors.

Models of Clean Benches

Labtron Clean Benches are specialized for controlling and cleaning air at certain level ensuring minimal contamination. Their surface is made from non-porous materials that are easy to sanitize and resistant to microbes. They are featured with sash shields and alarms to prevent accidental exposure from hazardous agents. Their adjustable airflow system allows to set both rate and direction according to requirement. Our Clean Benches are versatile for cosmetic manufacturing, Aerospace industry, Biomedical engineering and medical research.

Horizontal laminar flow clean bench LHCB-A10

Horizontal laminar flow clean bench LHCB-A10

  • External dimension (W x L x H) : 1590 x 800 x 1800 mm
  • Internal dimension (W x L x H) : 1430 x 620 x 575 mm
  • Illumination : ≥ 300 lux
  • Purification rank (ISO 14644-1 Std.) : 100
Vertical Laminar Flow Clean Bench LVCB-C11

Vertical Laminar Flow Clean Bench LVCB-C11

  • External Dimension : 1480 × 740 × 1700 mm
  • Internal Dimension : 1320 × 680 × 520 mm
  • Airflow Velocity : 0.3 to 0.5m/s
  • HEPA Filter : > 99.999% efficiency at 0.3 µm
Vertical Laminar Flow Clean Bench LVCB-A14

Vertical Laminar Flow Clean Bench LVCB-A14

  • External Dimension (W× L × H) : 1200mm × 700mm × 800mm
  • Work Area Size (W× L × H) : 1100mm × 650mm × 600mm
  • Illumination : >300ux
  • Airflow Velocity : 1800m³/h
Vertical laminar flow clean bench LVCB-A10
Vertical laminar flow clean bench LVCB-A10
  • External dimension (W x L x H) : 1000 x 700 x 1800 mm
  • Internal dimension (W x L x H) : 900 x 650 x 600 mm
  • Illumination : ≥ 400 lux
  • Purification rank (ISO 14644-1 Std.) : 100
Horizontal laminar flow clean bench LHCB-A11
Horizontal laminar flow clean bench LHCB-A11
  • External dimension (W x L x H) : 1340 x 800 x 1800 mm
  • Internal dimension (W x L x H) : 1180 x 620 x 575 mm
  • Illumination : ≥ 300 lux
  • Purification rank (ISO 14644-1 Std.) : 100
Vertical laminar flow clean bench LVCB-B10

Vertical laminar flow clean bench LVCB-B10

  • External dimension (W x L x H) : 1000 x 980 x 1900 mm
  • Internal dimension (W x L x H) : 900 x 680 x 600 mm
  • Illumination : ≥ 300 lux
  • Purification rank (ISO 14644-1 Std.) : 100
Horizontal laminar flow clean bench LHCB-B12

Horizontal laminar flow clean bench LHCB-B12

  • External dimension (W x L x H) : 1500 x 900 x 1580 mm
  • Internal dimension (W x L x H) : 1470 x 600 x 850 mm
  • Illumination : ≥ 300 lux
  • Purification rank (ISO 14644-1 Std.) : 100
Vertical Laminar Flow Clean Bench LVCB-C10

Vertical Laminar Flow Clean Bench LVCB-C10

  • External Dimension : 1000 × 740 × 1650 mm
  • Internal Dimension : 840 × 680 × 520 mm
  • Airflow Velocity : 0.3 to 0.5m/s
  • HEPA Filter : > 99.999% efficiency at 0.3 µm

Horizontal Laminar Flow Clean Bench LHCB-B17 FAQ's
  • Labtron supplies premium models of Horizontal Laminar Flow Clean Bench LHCB-B17. Regular maintenance is critical for sustained performance and contamination control. The HEPA or ULPA filters should be inspected and replaced as per manufacturer guidelines, typically once every 1–3 years depending on use. Pre-filters should be checked monthly and cleaned or replaced when dirty. Work surfaces and interiors must be disinfected routinely using suitable sterile wipes. Airflow velocity should be monitored to ensure it remains within the specified range. Any changes in airflow pattern or noise levels should be reported immediately. UV lamps, if installed, must be regularly cleaned and replaced as they degrade over time. Annual professional calibration and validation ensure continued compliance.

  • No, Horizontal Laminar Flow Clean Bench LHCB-B17 are not designed for handling biohazardous or volatile chemical substances. Since the air flows directly toward the operator, it does not provide personal protection. Using hazardous materials in these benches can result in operator exposure and environmental contamination. For such applications, a Biosafety Cabinet or Fume Hood should be used instead. These alternatives offer both product and user protection through exhaust systems and negative pressure environments. Always refer to institutional safety protocols before selecting a bench for hazardous tasks. The laminar flow bench is strictly for sterile, non-hazardous work. Misuse can lead to serious health and safety risks.

  • Selecting the appropriate size and model depends on your lab space, process requirements, and the volume of work. Measure the available installation space carefully to accommodate both the unit and working comfort. Consider the type of tasks you will perform—larger samples or equipment may require wider benches. Review airflow specifications, filter type (HEPA or ULPA), and noise levels for operator comfort. Check for ergonomic features such as adjustable stands, LED lighting, and low vibration fans. Some models also include digital displays and real-time airflow monitoring for added control. Compliance with ISO and GMP standards is also critical. Consult with technical experts or suppliers before purchase.

  • It is generally recommended to let the Horizontal Laminar Flow Bench LHCB-B17 run for at least 15 to 30 minutes before beginning any sterile work. This waiting period allows the airflow to stabilize and purge any contaminants that may have entered while the unit was off. During this time, airborne particles inside the chamber are swept away by the laminar air stream. Starting work too early may compromise product sterility. The pre-run time is particularly important in environments with heavy foot traffic or dust. Always close doors or windows near the unit during this time. Consistent pre-operation use increases process reliability. Follow manufacturer protocols for warm-up periods.

  • Yes, Horizontal Laminar Flow Bench LHCB-B17 are commonly installed in cleanrooms to support critical contamination-sensitive operations. They help maintain localized ISO Class 5 or better clean zones within larger cleanroom environments. These benches serve as secondary barriers where higher protection is needed for samples. In cleanrooms, their performance complements the room’s central air handling system. They can be strategically placed in production lines, quality control areas, or near aseptic filling zones. Proper integration involves ensuring compatibility with cleanroom airflow and pressure balance. Stainless steel construction and smooth surfaces make them suitable for cleanroom cleaning protocols. Ensure compliance with cleanroom validation standards before use.

Post your question?

Our experts are here to help!

Clean Benches:
Horizontal laminar flow clean bench LHCB-A10, Vertical Laminar Flow Clean Bench LVCB-C11, Vertical Laminar Flow Clean Bench LVCB-A14, Vertical laminar flow clean bench LVCB-A10, Horizontal laminar flow clean bench LHCB-A11, Vertical laminar flow clean bench LVCB-B10, Horizontal laminar flow clean bench LHCB-B12, Vertical Laminar Flow Clean Bench LVCB-C10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.