Horizontal Laminar Flow Clean Bench LHCB-B17 provides an airflow velocity of 1800m³/h to continuously clear contaminants from the work surface, preserving sterile conditions. The clean bench features a turbulence-free laminar stream for unidirectional airflow, continuously sweeps away particles without turbulent mixing. It is equipped with UV sterilization options, reducing the microbial load. Our horizontal laminar flow clean bench offers ultra-thin non-partition filters, providing filtration efficiency that can reach the static level.
| External Dimension (W× L × H) | 1200 mm × 820 mm × 1500 mm |
| Work Area Size (W× L × H) | 1130 mm × 600 mm × 600 mm |
| Illumination | >300 ux |
| Airflow Velocity | 1800 m³/h |
| Average Wind Speed | 0.3 to 0.6 m/s |
| LED Standard | 30 × 1 |
| Cleanliness Grade | Level 100 |
| Noise Level | ≤65 |
| Filtration Efficiency (% at 0.3µm) | 99.99 |
| Material | Cold-rolled steel plate with powder-coated or sand-ground stainless steel |
| Power Supply | 220/50 V/Hz |
| Power Consumption | 700 W |
Corrosion‑Resistant Stainless Surface
Durable Powder‑Coated Structure
Integrated LED Illumination
Adjustable Fan Speed
Real‑Time Airflow Alarm
Horizontal Laminar Flow Clean Bench LHCB-B17 is an enclosed bench device with rear-mounted HEPA filtration that sweeps clean, unidirectional air. It is applied in medical and health, optics, optoelectronics, microbiological testing and food sectors.
Download catalog for
Horizontal Laminar Flow Clean Bench LHCB-B17 Catalog
Available Range :
Vertical Laminar Flow Clean Bench LVCB-A13 : 1000mm × 700mm × 600mm Horizontal Laminar Flow Clean Bench LHCB-B17 : 1200 mm × 820 mm × 1500 mm Vertical Laminar Flow Clean Bench LVCB-A14 : 1200mm × 700mm × 800mm Horizontal Laminar Flow Clean Bench LHCB-B18 : 1500 mm × 820 mm × 1500 mm Vertical Laminar Flow Clean Bench LVCB-A15 : 1500mm × 700mm × 800mm Horizontal Laminar Flow Clean Bench LHCB-B16 : 960 mm × 780 mm × 1500 mmLabtron Clean Benches are specialized for controlling and cleaning air at certain level ensuring minimal contamination. Their surface is made from non-porous materials that are easy to sanitize and resistant to microbes. They are featured with sash shields and alarms to prevent accidental exposure from hazardous agents. Their adjustable airflow system allows to set both rate and direction according to requirement. Our Clean Benches are versatile for cosmetic manufacturing, Aerospace industry, Biomedical engineering and medical research.








Labtron supplies premium models of Horizontal Laminar Flow Clean Bench LHCB-B17. Regular maintenance is critical for sustained performance and contamination control. The HEPA or ULPA filters should be inspected and replaced as per manufacturer guidelines, typically once every 1–3 years depending on use. Pre-filters should be checked monthly and cleaned or replaced when dirty. Work surfaces and interiors must be disinfected routinely using suitable sterile wipes. Airflow velocity should be monitored to ensure it remains within the specified range. Any changes in airflow pattern or noise levels should be reported immediately. UV lamps, if installed, must be regularly cleaned and replaced as they degrade over time. Annual professional calibration and validation ensure continued compliance.
No, Horizontal Laminar Flow Clean Bench LHCB-B17 are not designed for handling biohazardous or volatile chemical substances. Since the air flows directly toward the operator, it does not provide personal protection. Using hazardous materials in these benches can result in operator exposure and environmental contamination. For such applications, a Biosafety Cabinet or Fume Hood should be used instead. These alternatives offer both product and user protection through exhaust systems and negative pressure environments. Always refer to institutional safety protocols before selecting a bench for hazardous tasks. The laminar flow bench is strictly for sterile, non-hazardous work. Misuse can lead to serious health and safety risks.
Selecting the appropriate size and model depends on your lab space, process requirements, and the volume of work. Measure the available installation space carefully to accommodate both the unit and working comfort. Consider the type of tasks you will perform—larger samples or equipment may require wider benches. Review airflow specifications, filter type (HEPA or ULPA), and noise levels for operator comfort. Check for ergonomic features such as adjustable stands, LED lighting, and low vibration fans. Some models also include digital displays and real-time airflow monitoring for added control. Compliance with ISO and GMP standards is also critical. Consult with technical experts or suppliers before purchase.
It is generally recommended to let the Horizontal Laminar Flow Bench LHCB-B17 run for at least 15 to 30 minutes before beginning any sterile work. This waiting period allows the airflow to stabilize and purge any contaminants that may have entered while the unit was off. During this time, airborne particles inside the chamber are swept away by the laminar air stream. Starting work too early may compromise product sterility. The pre-run time is particularly important in environments with heavy foot traffic or dust. Always close doors or windows near the unit during this time. Consistent pre-operation use increases process reliability. Follow manufacturer protocols for warm-up periods.
Yes, Horizontal Laminar Flow Bench LHCB-B17 are commonly installed in cleanrooms to support critical contamination-sensitive operations. They help maintain localized ISO Class 5 or better clean zones within larger cleanroom environments. These benches serve as secondary barriers where higher protection is needed for samples. In cleanrooms, their performance complements the room’s central air handling system. They can be strategically placed in production lines, quality control areas, or near aseptic filling zones. Proper integration involves ensuring compatibility with cleanroom airflow and pressure balance. Stainless steel construction and smooth surfaces make them suitable for cleanroom cleaning protocols. Ensure compliance with cleanroom validation standards before use.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608