Request A Quote
Horizontal Laminar Flow Clean Bench LHCB-B18

Horizontal Laminar Flow Clean Bench LHCB-B18

Horizontal Laminar Flow Clean Bench LHCH-B18 features an average wind speed of 0.3 to 0.6m/s, maintaining smooth, particle‑free airflow across the work surface. It provides uniform horizontal airflow that sweeps away particles in a laminar stream to maintain sterile conditions. The system has real-time airflow alarms, enabling immediate alert on airflow deviation to maintain laminar conditions. Our horizontal laminar flow clean bench is made from cold‑rolled steel finished with anti‑bacterial powder coating with sand‑ground stainless steel work surface for corrosion resistance and easy cleaning.

Horizontal Laminar Flow Clean Bench LHCB-B18_Front View
Horizontal Laminar Flow Clean Bench LHCB-B18_Side View
Horizontal Laminar Flow Clean Bench LHCB-B18_ Side View
Request Quote
External Dimension (W× L × H) 1500 mm × 820 mm × 1500 mm
Work Area Size (W× L × H) 1430 mm × 600 mm × 600 mm
Illumination >300 ux
Airflow Velocity 2300 m³/h
Average Wind Speed 0.3 to 0.6 m/s
LED Standard 40 × 1
Cleanliness Grade Level 100
Noise Level ≤65
Filtration Efficiency (% at 0.3µm) 99.99
Material Cold-rolled steel plate with powder-coated or sand-ground stainless steel
Power Supply 220/50 V/Hz
Power Consumption 700 W
  • UV Sterilization Option

  • Pressure Monitoring Gauge

  •  Multiple Bench Widths

  • Pre‑Filter Maintenance Alert 

  • Electronic Control Mode

Horizontal Laminar Flow Clean Bench LHCB-B18 protects sensitive samples from airborne contamination using horizontal HEPA filters. It is extensively utilized in scientific environment, production department, biopharmaceuticals and sterile microbiology testing.

Models of Clean Benches

Labtron Clean Benches are specialized for controlling and cleaning air at certain level ensuring minimal contamination. Their surface is made from non-porous materials that are easy to sanitize and resistant to microbes. They are featured with sash shields and alarms to prevent accidental exposure from hazardous agents. Their adjustable airflow system allows to set both rate and direction according to requirement. Our Clean Benches are versatile for cosmetic manufacturing, Aerospace industry, Biomedical engineering and medical research.

Vertical laminar flow clean bench LVCB-B10

Vertical laminar flow clean bench LVCB-B10

  • External dimension (W x L x H) : 1000 x 980 x 1900 mm
  • Internal dimension (W x L x H) : 900 x 680 x 600 mm
  • Illumination : ≥ 300 lux
  • Purification rank (ISO 14644-1 Std.) : 100
Horizontal Laminar Flow Clean Bench LHCB-B17

Horizontal Laminar Flow Clean Bench LHCB-B17

  • External Dimension (W× L × H) : 1200 mm × 820 mm × 1500 mm
  • Work Area Size (W× L × H) : 1130 mm × 600 mm × 600 mm
  • Illumination : >300 ux
  • Airflow Velocity : 1800 m³/h
Horizontal laminar flow clean bench LHCB-A10

Horizontal laminar flow clean bench LHCB-A10

  • External dimension (W x L x H) : 1590 x 800 x 1800 mm
  • Internal dimension (W x L x H) : 1430 x 620 x 575 mm
  • Illumination : ≥ 300 lux
  • Purification rank (ISO 14644-1 Std.) : 100
Horizontal laminar flow clean bench LHCB-B11
Horizontal laminar flow clean bench LHCB-B11
  • External dimension (W x L x H) : 1200 x 820 x 1580 mm
  • Internal dimension (W x L x H) : 1170 x 600 x 650 mm
  • Illumination : ≥ 300 lux
  • Purification rank (ISO 14644-1 Std.) : 100
Horizontal Laminar Flow Clean Bench LHCB-B14
Horizontal Laminar Flow Clean Bench LHCB-B14
  • External Dimension (W × L × H) : 840mm × 820mm × 1430mm
  • Internal Dimension (W × L × H) : 720mm × 650mm × 570mm
  • Illumination : More than or equal to 300lux
  • Air Flow : 1152 to 2376 m³⁄h (Recommended speed: 0.3m/s)
Horizontal Laminar Flow Clean Bench LHCB-C11

Horizontal Laminar Flow Clean Bench LHCB-C11

  • Airflow Velocity : 0.3 to 0.5 m/s
  • HEPA Filter : > 99.999% efficiency at 0.3 µm
  • Cleanliness Grade : ISO Class 5, Class 100 (Fed 209E)
  • Noise : ≤65 dB(A)
Vertical laminar flow clean bench LVCB-A10

Vertical laminar flow clean bench LVCB-A10

  • External dimension (W x L x H) : 1000 x 700 x 1800 mm
  • Internal dimension (W x L x H) : 900 x 650 x 600 mm
  • Illumination : ≥ 400 lux
  • Purification rank (ISO 14644-1 Std.) : 100
Vertical laminar flow clean bench LVCB-A11

Vertical laminar flow clean bench LVCB-A11

  • External dimension (W x L x H) : 1200 x 700 x 1800 mm
  • Internal dimension (W x L x H) : 1100 x 650 x 600 mm
  • Illumination : ≥ 400 lux
  • Purification rank (ISO 14644-1 Std.) : 100

Horizontal Laminar Flow Clean Bench LHCB-B18 FAQ's
  • Labtron supplies advanced models of Horizontal Laminar Flow Clean Bench LHCB-B18.The unit draws in ambient air, which then passes through a pre-filter to remove large particles. This air is further purified using a High-Efficiency Particulate Air (HEPA) filter to trap of particles. Once filtered, the clean air flows horizontally in a uniform direction from the back of the bench toward the operator. This laminar flow pushes any contaminants away from the work area. The consistent airflow prevents turbulence, which could introduce contamination. The system runs continuously during operations to maintain a sterile field. Integrated blowers help sustain the airflow at a defined velocity. This mechanism ensures a high level of cleanliness suitable for sensitive processes.

  • Labtron’s Horizontal Laminar Flow Benches LHCB-B18 are commonly used in applications where sample protection is critical. These include microbiology labs, electronics assembly, plant tissue culture, pharmaceutical production, and sterile drug preparation. They are ideal for procedures like media preparation, filter integrity testing, and assembling medical devices. The bench ensures that the product remains contamination-free during handling. However, they are unsuitable for handling biohazards or hazardous chemicals. Since airflow is directed toward the user, operator safety is not guaranteed. Therefore, they are strictly for applications where only product protection is needed. Their versatility makes them a staple in research and production labs.

  • The key difference lies in the direction of airflow. In a horizontal laminar flow bench, clean air flows from the rear of the bench directly toward the user. In contrast, vertical laminar flow benches direct air from the top of the unit downward onto the work surface. Horizontal flow minimizes turbulence over the workspace and is generally gentler on delicate materials. Vertical flow reduces the risk of contamination reaching the user but can create turbulence on large objects. Horizontal models are more ergonomic for some users during prolonged tasks. Each configuration suits different application needs based on airflow and space design. Safety and contamination control are tailored accordingly.

  • No, Horizontal Laminar Flow Clean Bench LHCB-B18 are not designed for handling biohazardous or volatile chemical substances. Since the air flows directly toward the operator, it does not provide personal protection. Using hazardous materials in these benches can result in operator exposure and environmental contamination. For such applications, a Biosafety Cabinet or Fume Hood should be used instead. These alternatives offer both product and user protection through exhaust systems and negative pressure environments. Always refer to institutional safety protocols before selecting a bench for hazardous tasks. The laminar flow bench is strictly for sterile, non-hazardous work. Misuse can lead to serious health and safety risks

  • Selecting the appropriate size and model depends on your lab space, process requirements, and the volume of work. Measure the available installation space carefully to accommodate both the unit and working comfort. Consider the type of tasks you will perform—larger samples or equipment may require wider benches. Review airflow specifications, filter type (HEPA or ULPA), and noise levels for operator comfort. Check for ergonomic features such as adjustable stands, LED lighting, and low vibration fans. Some models also include digital displays and real-time airflow monitoring for added control. Compliance with ISO and GMP standards is also critical. Consult with technical experts or suppliers before purchase

Post your question?

Our experts are here to help!

Clean Benches:
Vertical laminar flow clean bench LVCB-B10, Horizontal Laminar Flow Clean Bench LHCB-B17, Horizontal laminar flow clean bench LHCB-A10, Horizontal laminar flow clean bench LHCB-B11, Horizontal Laminar Flow Clean Bench LHCB-B14, Horizontal Laminar Flow Clean Bench LHCB-C11, Vertical laminar flow clean bench LVCB-A10, Vertical laminar flow clean bench LVCB-A11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608