Vertical Laminar Flow Clean Bench LVCB-A13 features an average wind speed of 0.3 to 0.6 m/s, ensuring smooth, particle-free airflow across the work surface. It provides uniform horizontal airflow that sweeps away particles in a laminar stream, maintaining sterile conditions. The system has real-time airflow alarms, enabling immediate alert on airflow deviation to maintain laminar conditions. Our horizontal laminar flow clean bench is constructed from cold-rolled steel finished with anti‑bacterial powder coating for corrosion resistance and easy cleaning.
| External Dimension (W× L × H) | 1000mm × 700mm × 600mm |
| Work Area Size (W× L × H) | 900mm × 650mm × 600mm |
| Illumination | >300ux |
| Airflow Velocity | 1200m³/h |
| Average Wind Speed | 0.3 to 0.6m/s |
| LED Standard | 20 × 1 |
| Cleanliness Grade | Level 100 |
| Noise Level | ≤65 |
| Filtration Efficiency (% at 0.3µm) | 99.99 |
| Material | Cold-rolled steel plate sprayed with plastic or stainless-steel. table top is sanded stainless steel |
| Power Supply | 220/50 V/Hz |
| Power Consumption | 200W |
High-efficiency Clean Airflow
Adjustable Vertical Airflow Speed
UV‑C Germicidal Lamp Timed Cycles
Waterproof IP‑Rated Power Sockets
Washable Polyester Pre‑Filter
Vertical Laminar Flow Clean Bench LVCB-A13 directs the filtered air downward onto the work surface in a uniform vertical beam. It plays a key role in pharmaceutical, biotechnology, microbiology, life science and forensics.
Download catalog for
Vertical Laminar Flow Clean Bench LVCB-A13 Catalog
Available Range :
Vertical Laminar Flow Clean Bench LVCB-A13 : 1000mm × 700mm × 600mm Horizontal Laminar Flow Clean Bench LHCB-B17 : 1200 mm × 820 mm × 1500 mm Vertical Laminar Flow Clean Bench LVCB-A14 : 1200mm × 700mm × 800mm Horizontal Laminar Flow Clean Bench LHCB-B18 : 1500 mm × 820 mm × 1500 mm Vertical Laminar Flow Clean Bench LVCB-A15 : 1500mm × 700mm × 800mm Horizontal Laminar Flow Clean Bench LHCB-B16 : 960 mm × 780 mm × 1500 mmLabtron Clean Benches are specialized for controlling and cleaning air at certain level ensuring minimal contamination. Their surface is made from non-porous materials that are easy to sanitize and resistant to microbes. They are featured with sash shields and alarms to prevent accidental exposure from hazardous agents. Their adjustable airflow system allows to set both rate and direction according to requirement. Our Clean Benches are versatile for cosmetic manufacturing, Aerospace industry, Biomedical engineering and medical research.








Labtron’s Vertical Laminar Flow Clean Bench LVCB-A13 is a dedicated laboratory workstation designed to protect samples by directing HEPA filtered air in a smooth, unidirectional vertical downward flow. This airflow pattern creates an sterile environment over the work surface, effectively removing particulates and minimizing contamination. Unlike biosafety cabinets or fume hoods, it does not protect the user—its primary purpose is sample protection. Air is drawn through a pre-filter, then through a HEPA or ULPA filter at the top, and flows downward across the workspace before exiting at the front opening.
Labtron supplies advanced models of vertical laminar flow clean bench LHCV-A13.Airflow velocity in a vertical laminar flow bench is typically calibrated between 0.3 to 0.5?m/s ensuring consistent, unidirectional movement that minimizes turbulence and cross contamination. This controlled airflow washes clean air over the entire work zone uniformly and is critical for maintaining ISO Class?5 conditions. Speed is often adjustable via built in controllers and monitored via sensors or pressure gauges. Regular velocity testing is performed for certification and to verify performance over time.
In a vertical configuration, the HEPA or ULPA filter is mounted above the workspace and air flows downward, reducing contamination risk from operator’s hands and tools. Horizontal benches place the filter at the back, blowing clean air across the work surface toward the user. Vertical flow benches save benchtop depth and work well with tall equipment, while horizontal flow can offer slightly improved protection by ensuring operator-caused particles are pushed away. Each type offers unique benefits depending on lab design and application requirements.
Labtron’s Vertical laminar flow clean benches LVCB-A13 are typically equipped with HEPA filters or optional ULPA filters for more stringent applications. Ambient air passes through a washable pre-filter before reaching the high-efficiency HEPA/ULPA filter, prolonging filter life. These filters are crucial for achieving and maintaining ISO Class?5 cleanliness. Replacement schedules and efficiency monitoring are routinely required for certification and performance assurance.
Labtron’s vertical laminar flow clean benches LVCB-A13 are well-suited for tasks requiring a sterile environment such as electronics assembly, optical device preparation, PCR setup, tissue or plant culture, and mycology work (e.g. mushroom spore handling). They are favored where equipment is tall or bulky, or where downward airflow helps displace particulates more effectively. UV C lamps are often included to sterilize the interior before use, especially in PCR or biological sample prep. These benches meet laboratory cleanliness standards without needing a full cleanroom build-out.