| Airflow Velocity | 0.3 to 0.5 m/s |
| HEPA Filter | > 99.999% efficiency at 0.3 µm |
| Cleanliness Grade | ISO Class 5, Class 100 (Fed 209E) |
| Noise | ≤65 dB(A) |
| RMS | ≤ 4 μm |
| Fluorescent Light | 16 W LED |
| UV Light | 21 W |
| Power Consumption | ≤ 0.5 Kw |
| Power Supply | AC 220 ± 10% / 50 HZ |
| External Dimension | 1500 × 750 × 1470 mm |
| Internal Dimension | 1420 × 500 × 600 mm |
| Net Weight | 80 Kg |
Enhanced HEPA Filter System
Adjustable Air Velocity
Low Noise Operation
UV Sterilization Lamp
Anti-Static Work Surface
Our Horizontal Laminar Flow Clean Bench is widely used in microbiology, pharmaceuticals, electronics, medical devices, food testing, plant tissue culture, optics, cosmetics to provide a contamination-free and sterile working environment.
Accessory Name | Quantity |
Electric Socket | 1 |
Floor Stand | 1 |
Illumination Bulb | 1 |
Accessory Name | Quantity |
UV Light | 1 |
Gas Valve | 1 |
Water Valve | 1 |
Download catalog for
Horizontal Laminar Flow Clean Bench LHCB-C11 Catalog
Available Range :
Horizontal Laminar Flow Clean Bench LHCB-C10 : 0.3 to 0.5 m/s Vertical Laminar Flow Clean Bench LVCB-C10 : 0.3 to 0.5m/s Horizontal Laminar Flow Clean Bench LHCB-B16 : 1200 m³/h Vertical Laminar Flow Clean Bench LVCB-A13 : 1200m³/h Horizontal Laminar Flow Clean Bench LHCB-B17 : 1800 m³/h Vertical Laminar Flow Clean Bench LVCB-A14 : 1800m³/h Horizontal Laminar Flow Clean Bench LHCB-B18 : 2300 m³/h Vertical Laminar Flow Clean Bench LVCB-A15 : 2300m³/h
Labtron Clean Benches are specialized for controlling and cleaning air at certain level ensuring minimal contamination. Their surface is made from non-porous materials that are easy to sanitize and resistant to microbes. They are featured with sash shields and alarms to prevent accidental exposure from hazardous agents. Their adjustable airflow system allows to set both rate and direction according to requirement. Our Clean Benches are versatile for cosmetic manufacturing, Aerospace industry, Biomedical engineering and medical research.








The HEPA filter typically needs replacement every 1 to 3 years, depending on usage intensity and the working environment. Frequent use in dusty or particle-heavy settings may require earlier replacement. It’s important to monitor airflow performance regularly, as a clogged filter reduces airflow efficiency and compromises sterility. Many clean benches include filter life indicators or alarms to notify users when replacement is needed. Timely replacement ensures continuous protection against airborne contaminants. Neglecting filter maintenance can lead to contamination risks and equipment damage.
Yes, continuous operation during use is important to maintain a steady flow of sterile air and prevent contaminants from settling on the work surface. Turning the unit off intermittently can allow dust and particles to accumulate, compromising sterility. Clean benches typically use energy-efficient motors designed for long-duration use without overheating. When the bench is not in use, it’s advisable to run the UV sterilization lamp to disinfect the workspace. Continuous airflow helps maintain a contamination-free environment and protects sensitive materials. Proper operation practices optimize both safety and equipment performance.
The UV sterilization lamp in a Horizontal Laminar Flow Clean Bench LHCB-C11 emits ultraviolet-C (UV-C) light that destroys microorganisms by damaging their DNA and RNA. It is usually operated when the bench is not in use to disinfect the work surface and internal air pathways. UV sterilization helps reduce microbial contamination risks before starting sensitive procedures. However, UV light can be harmful to skin and eyes, so the bench is designed with safety features to prevent exposure during operation. Regular use of UV sterilization complements the HEPA filtration system for comprehensive cleanliness. Proper timing and maintenance of the UV lamp are essential for effective sterilization.
The Horizontal Laminar Flow Clean Bench LHCB-C11 operate at noise levels around ?65 decibels, which is comparable to normal office background noise. Low noise levels are important to provide a comfortable working environment, especially during long laboratory procedures. Excessive noise can cause distractions and reduce concentration, impacting work quality and safety. Quiet operation also helps in maintaining a calm lab atmosphere and reduces stress for personnel. The design often incorporates sound-dampening materials and low-vibration fans to minimize noise. Maintaining low noise without compromising airflow performance is a key feature of quality clean benches.
Horizontal Laminar Flow Clean Bench LHCB-C11 comply with international electrical safety standards such as IEC 61010 or equivalent, ensuring safe operation in laboratory environments. Features typically include grounded power cords, circuit breakers, and overload protection to prevent electrical hazards. Many units also have control panels with safety interlocks for UV lamps and fans to avoid accidental exposure or malfunction. Emergency shut-off switches and alarms for airflow failure may be included for user safety. Compliance with these standards ensures the clean bench operates safely and reliably. Regular electrical inspections and certifications are recommended for continued safety assurance.