| Airflow Velocity | 0.3 to 0.5 m/s |
| HEPA Filter | > 99.999% efficiency at 0.3 µm |
| Cleanliness Grade | ISO Class 5, Class 100 (Fed 209E) |
| Sound Emission | ≤ 65 dB(A) |
| RMS | ≤ 4 µm |
| Fluorescent Light | 16 W LED |
| UV Light | 21 W |
| Power Consumption | ≤ 0.5 Kw |
| Power Supply | AC 220 ± 10% / 50 HZ |
| External Dimension | 1000 × 750 × 1470 mm |
| Internal Dimension | 920 × 500 × 600 mm |
| Net Weight | 50 Kg |
Low-Turbulence Airflow
Transparent Side Panels
Integrated LCD Monitoring Display
Bright Illumination Lamp
Compact and Ergonomic Design
Our Horizontal Laminar Flow Clean Bench ensures contamination control during critical processes such as sample handling, inspection, and packaging in laboratories and cleanroom environments for reliable and sterile results.
Accessory Name | Quantity |
Electric Socket | 1 |
Floor Stand | 1 |
Illumination Bulb | 1 |
Accessory Name | Quantity |
UV Light | 1 |
Gas Valve | 1 |
Water Valve | 1 |
Download catalog for
Horizontal Laminar Flow Clean Bench LHCB-C10 Catalog
Available Range :
Horizontal Laminar Flow Clean Bench LHCB-C10 : 0.3 to 0.5 m/s Vertical Laminar Flow Clean Bench LVCB-C10 : 0.3 to 0.5m/s Horizontal Laminar Flow Clean Bench LHCB-B16 : 1200 m³/h Vertical Laminar Flow Clean Bench LVCB-A13 : 1200m³/h Horizontal Laminar Flow Clean Bench LHCB-B17 : 1800 m³/h Vertical Laminar Flow Clean Bench LVCB-A14 : 1800m³/h Horizontal Laminar Flow Clean Bench LHCB-B18 : 2300 m³/h Vertical Laminar Flow Clean Bench LVCB-A15 : 2300m³/h
Labtron Clean Benches are specialized for controlling and cleaning air at certain level ensuring minimal contamination. Their surface is made from non-porous materials that are easy to sanitize and resistant to microbes. They are featured with sash shields and alarms to prevent accidental exposure from hazardous agents. Their adjustable airflow system allows to set both rate and direction according to requirement. Our Clean Benches are versatile for cosmetic manufacturing, Aerospace industry, Biomedical engineering and medical research.








The primary function of the Horizontal Laminar Flow Clean Bench LHCB-C10 is to provide a sterile and contamination-free workspace by directing filtered air in a horizontal laminar flow across the work surface. This continuous airflow removes airborne contaminants, protecting sensitive samples and processes. It is ideal for tasks such as sample preparation, inspection, and packaging where contamination control is critical. The HEPA filter ensures removal of particles as small as 0.3 microns with 99.99% efficiency. Additionally, the built-in UV light can sterilize the workspace when the bench is not in use. This combination of features supports maintaining a clean environment suitable for laboratories and cleanrooms.
The HEPA filter in the Horizontal Laminar Flow Clean Bench LHCB-C10 plays a crucial role in removing 99.99% of airborne particles larger than 0.3 microns, including dust, microbes, and other contaminants. This high-efficiency filtration ensures that the air blowing over the work surface is free from harmful particles, thereby protecting samples and experimental processes from contamination. It enhances lab safety by minimizing the risk of exposure to potentially hazardous biological or chemical materials. The filter is easy to maintain and replace, ensuring long-term performance. By providing a controlled clean airflow, the HEPA filter helps labs meet stringent cleanliness standards required for sensitive applications.
Yes, the Horizontal Laminar Flow Clean Bench LHCB-C10 can be customized to meet specific laboratory requirements. Options may include varying internal sizes, additional electrical outlets, different types of illumination such as LED lamps, or enhanced filtration systems. Some models allow integration with monitoring systems for airflow and filter status to suit advanced lab environments. Customization ensures the clean bench can accommodate diverse applications such as pharmaceutical preparation, electronics assembly, or microbiological research. Users should consult with suppliers or manufacturers to select the best configuration based on their operational needs.
The integrated LCD screen in the Horizontal Laminar Flow Clean Bench LHCB-C10 provides real-time monitoring of critical parameters such as airflow velocity, filter status, and operating time. This feature allows users to quickly verify that the clean bench is functioning within safe and optimal limits. It also simplifies maintenance by alerting users when filter replacement or UV lamp servicing is needed. The clear display enhances user confidence by providing easy access to performance data without disrupting work. Overall, the LCD screen helps ensure safety, reliability, and efficient operation in laboratory workflows.
The UV light in the Horizontal Laminar Flow Clean Bench LHCB-C10 is designed for surface sterilization to eliminate bacteria, viruses, and fungi on the internal surfaces of the clean bench. It should be operated only when the bench is not in use and the front sash is closed, to prevent exposure to harmful UV radiation. Running the UV light before and after work sessions helps maintain a sterile environment by killing residual microorganisms. This sterilization step is crucial in microbiology, pharmaceutical, and medical laboratories where contamination must be minimized. Users should follow manufacturer guidelines to avoid overuse and ensure the UV lamp’s effectiveness.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608