Atomic absorption spectrophotometer comes with Deuterium lamp for background correction, RS232 interface, Multi-linear and nonlinear curve fitting. Its double beam system automatically compensates the light source drift and wavelength drift caused by the variation of temperature and electronic circuit drift so as to reach a good basic line stability. The specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration in this atomic absorption spectrophotometer. It has multiple applications in research and development and industrial analysis.
Wavelength range | 190 - 900 nm |
Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
Wavelength accuracy | ≤ ± 0.5 nm |
Wavelength repeatability | ≤ 0.3 nm(single direction) |
Baseline drift | ± 0.004 Abs / 30 min |
Resolution | < 40 % |
Characteristic concentration (Cu) | ≤ 0.04 mg / ml / 1 % |
Detection Limit (Cu) | 0.008 mg/ml |
Background calibration ability | Greater than 30 times |
Power supply | 220 V / 3 A, 50 Hz |
Gross Weight | 160 kg |
Dimension (L × W × H) | 1220 x 770 x 730 mm |
Atomic absorption spectrophotometer is used to analyze elements in agriculture, chemical, environmental study, food, mining, and petrochemical, pharmaceutical industries.
A graphite furnace system
Titanium burner—5cm
Nitrous oxide generator
Hydride generator
Graphite tubes
Acetylene regulator
Nitrous oxide regulator
Software
Recirculating cooling water system
Model | Monochromator | Wavelength range | Spectral Bandwidth | Wavelength accuracy | Wavelength repeatability | Baseline drift | Grating groove density | Sample Volume | The volume of sample | Repeated Sampling Frequency | Cleaning and waste container volume | Absorbance Range | The Program | Temperature Range | Detector | Heating Mode | Temperature Control Method | Temperature Control | Resolution | Lamp holder | Lamp current adjustment range | Lamp power supply mode | Optical System | Atomization Chamber | Characteristics Volume | Characteristic concentration (Cu) | Detection Limit | Detection Limit (Cu) | Background calibration ability | Burner | Nebulizer | Precision | Ignition Type | Sprayer | Room Spray | Sample Tray | The Smallest Lincrement | Safety measures | Gas Control | Measurement | Concentration calculation | The Cooling Water | The number of repeated measurements | Print results | Software Environment | Operating temperature | Working humidity | Power supply | Power (VAC) | Gross Weight | Weight | Dimension (L × W × H) |
LAAS-A13 | - | - | - | ± 0.15 nm | ≤ 0.04 nm | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V ± 22 V AC | - | - | - | - |
LAAS-A11 | - | 190 - 900 nm | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm | ≤ ± 0.5 nm | ≤ 0.3 nm(single direction) | ± 0.004 Abs / 30 min | - | - | - | - | - | - | - | - | - | - | - | - | < 40 % | - | - | - | - | - | - | ≤ 0.04 mg / ml / 1 % | - | 0.008 mg/ml | Greater than 30 times | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 220 V / 3 A, 50 Hz | - | 160 kg | - | 1220 x 770 x 730 mm |
LAAS-A20 | - | 180 - 900 nm | 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting) | ≤ 0.15 nm | ± 0.1 nm | ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic) | - | - | - | - | - | 0 - 4 A | - | - | Imported photomultiplier tube | - | - | - | - | ≤ 6 lamps automatic turret, automatic alignment | - | pulsed power supply | large 1800 /mm grating ruling, full closed optical system | Polymer explosion-proof spray chamber | - | 0.015 μg / mL / 1 % | - | 0.002 μg/mL | - | Full titanium combustion head, 50 mm or 100 mm general combustion head | Atomizer efficient glass atomizer,can also be customized | RSD ≤ 0.5 % | Microcomputer control, automatic ignition | - | - | - | - | - | Automatic gas control system | Flame method, Hydride generation-Atomic absorption method | Standard curve method(1 - 3 times curve), automatic fitting | - | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. | - | - | - | 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA | - | - | - | - |
LAAS-A21 | - | 180 – 900 nm | 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover) | ≤ 0.15 nm | ± 0.1 nm | ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic) | - | - | - | - | - | 0 - 4 A | - | - | - | - | - | - | - | ≤ 3 lamps automatic turret, automatic alignment | - | pulsed power supply | large 1800 /mm grating ruling, full closed optical system | Polymer explosion-proof spray chamber | - | 0.015 μg / mL / 1 % | - | 0.002 μg/mL | - | Full titanium combustion head, 50 mm or 100 mm general combustion head | Atomizer efficient glass atomizer,can also be customized | RSD ≤ 0.5 % | Microcomputer control, automatic ignition | - | - | - | - | - | Automatic gas control system | Flame method, Hydride generation-Atomic absorption method | Standard curve method(1 - 3 times curve), automatic fitting | - | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. | - | - | - | - | - | - | - | - |
LAAS-A22 | - | 180 – 900 nm | 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting | ≤ 0.15 nm | ± 0.1 nm | ≤ ± 0.002 Abs/30 min (Static) ≤ ± 0.005 Abs/30 min (Dynamic) | - | 1 - 100 μl | better than 1 %(at the time of 10 mL - 100 mL) | up to 99 Times | Each 500 mL | 0 - 4 A | Automatic temperature control up to 20 order | room temperature to 3000 ℃ | imported photomultiplier tube | vertical heating | Vertical optical temperature monitoring graphite tube wall temperature | The furnace enriched up to 20 times | - | ≤ 6 lamps automatic turret, automatic alignment | - | pulsed power supply | Large 1800 /mm grating ruling, full closed optical system | Polymer explosion-proof spray chamber | 0.5 × 10-12g (Cd) | 0.015 μg / mL / 1 % | 0.4 × 10-12g (Cd) | 0.002 μg/mL | - | Full titanium combustion head, 50 mm or 100 mm general combustion head | Atomizer efficient glass atomizer,can also be customized | RSD ≤ 0.5 | Microcomputer control, automatic ignition | - | - | 70 sample cups, 6 reagent cup | 0.1 μl | The graphite tube damage, water flow Air pressure and other alarm temperature overheating protection | Automatic gas control system | Flame method, Hydride generation-Atomic absorption method | Standard curve method(1 - 3 times curve), automatic fitting | Can choose cooling water circulation system | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. | - | - | - | 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA | - | - | - | - |
LAAS-A12 | C-T | 190 nm ~ 900 nm | - | ± 0.25 nm | 0.15 nm | - | - | - | - | - | - | - | - | - | Photomultiplier | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 100 mm metallic titanium | - | - | - | Glass, plastic and stainless steel | - | - | - | - | - | - | Standard curve, automatic matching, standard addition | - | - | - | - | - | - | AC 220 V / 50 Hz | - | - | 70 Kg | - |
LAAS-A23 | - | 185 to 900 nm | 0.1 nm,0.2 nm,0.4 nm, 0.7 nm, 1.0 nm, 1.4 nm, 2.0 nm automatic setting | ± 0.15 nm | < 0.1 nm | - | - | - | - | - | - | 0 to 4 A | Automatic temperature controls up to 20 order | Room temperature to 3000 ℃ | Imported photomultiplier tube | Vertical heating | Vertical optical temperature monitoring graphite tube wall temperature | The furnace enriched up to 20 times | - | ≤ 8 lamps automatic turret, automatic alignment | - | Pulsed power supply | Large 1800 /mm grating ruling, full closed optical system | Polymer explosion-proof spray chamber | 0.4 × 10-12g (Cd) | - | 0.4 × 10-12g (Cd) | 0.002 μg/mL | - | Full titanium combustion head, 50 mm or 100 mm general combustion head | Atomizer efficient glass atomizer, can also be customized | RSD ≤ 0.5 | Microcomputer control, automatic ignition | - | - | - | - | Graphite tube damage, water flow Air pressure and other alarm temperature overheating protection | Automatic gas control system | - | - | - | - | - | - | - | - | 110 / 220 V (+5 % to -10 %), 60 / 50 Hz; 5000 VA | - | - | - | - |