| Type | Vertical; constant temperature heating box type |
| Door opening | Manual |
| Capacity | 360 L |
| Sterilization temperature | 50℃ ± 3℃ |
| Work pressure | -60 kPa |
| Maximum pressure | -140 kPa |
| Humidity (sterilization) | 45% to 75% |
| Sterilizing gas | Ethylene oxide; 1g/L |
| Sterilization time | 3 to 99 hrs; adjustable |
| Vacuum speed | -60 kPa in 15 mins |
| Ventilation | Automatic |
| Ventilation cycle | 3 times; 30 mins interval once |
| Control system | Automatic; one-button |
| Display | Digital LCD display |
| Printer | Yes |
| Humidity sensor | Yes; cavity humidity: >45% RH |
| Pressure sensor | Yes |
| Temperature sensor | Yes; cavity temperature: 50℃ ± 3℃ (within precise range) |
| Vacuum system | Oil free vacuum pump |
| Heating system | Electric; explosion-proof electric heating device |
| Alarm system | High/low temperature |
| Protection features | over-voltage, over-temperature protection, residual air automatic processing system |
| Sterilization room material | 304 anti-corrosion type stainless steel |
| Outer box material | Carbon steel (thickness 1.8mm) baked plastic powder |
| Wear parts | Seal |
| Caster | Yes |
| Power | 3.6 kW |
| Chamber dimensions (W×D×H) | 600×830×730 mm |
| Dimensions (W×D×H) | 820×1010×1380 mm |
| Weight | 340 kg |
Ethylene Oxide Sterilizer used to sterilize catheters, resuscitation bags, anesthesia masks, most fiber-optic instruments, glassware, solution medium, assembled complex devices, Custom procedure packs, equipment with integrated electronics, multi-lumen tubing products, stents, wound care dressings etc. across the field of pharmaceutical industries, metal & glass industries, hospitals, laboratories and research institutes etc. This autoclave most suits for prosthetic implants (joint, hip and knee replacements) sterilization.
Download catalog for
Ethylene Oxide Sterilizer LEOS-A13 Catalog
Download manual for
Ethylene Oxide Sterilizer LEOS-A13 Manual
Labtron Ethylene Oxide Sterilizer is specialized for disinfection of heat-sensitive and complex materials. They offer effective microbial eradication by using ethylene oxide (EO) gas. Their insulation function minimizes energy loss, making them environment-friendly and cost-effective. They feature automated cycles and an efficient aeration system to improve the decontamination process thoroughly. Our Ethylene Oxide Sterilizer is applicable in hospitals, labs, and industries for decontaminating implants and instruments.








Labtron’s Ethylene Oxide Sterilizer is designed with multiple safety features, including automatic pressure and temperature controls. The explosion-proof heating device prevents overheating during operation. High and low-temperature alarms ensure safe sterilization cycles. The built-in ventilation system removes residual gas, reducing exposure risks. Additionally, the outer casing is made of durable materials to enhance operational safety.
Our Ethylene Oxide Sterilizer provides an advanced sterilization solution for heat-sensitive and moisture-sensitive items. Unlike steam sterilization, it operates without high temperatures or pressure, ensuring the safety of delicate instruments. The gas penetrates deeply into complex medical devices, guaranteeing thorough sterilization. It effectively eliminates all microorganisms, including resistant bacterial spores. This makes it one of the most dependable sterilization methods available.
Labtron’s Ethylene Oxide Sterilizer should always be used in a well-ventilated area to ensure safe operation. Proper aeration effectively removes any residual gas after sterilization, preventing harmful exposure. The built-in safety mechanisms regulate gas release, ensuring controlled emission and reducing accumulation risks. If used in enclosed spaces, an exhaust ventilation system is necessary to maintain air quality. Regular monitoring of gas levels and following safety protocols help create a secure working environment.
To maintain long-term efficiency, Labtron advises regular servicing and preventive maintenance of the Ethylene Oxide Sterilizer. Key components such as sensors, ventilation systems, and gas flow regulators should be inspected periodically. Proper cleaning prevents residue buildup, ensuring safe and effective sterilization cycles. Checking and replacing worn-out door seals and filters helps maintain airtight conditions. Scheduled maintenance enhances performance, extends equipment lifespan, and ensures consistent sterilization quality.
Sterilizing intricate medical instruments requires a method that reaches every internal surface. Ethylene oxide sterilization utilizes gas diffusion to penetrate fine tubing, lumens, and electronic components effectively. This low-temperature process is ideal for delicate equipment that cannot withstand heat or moisture. Its controlled sterilization cycle ensures even gas distribution, eliminating all harmful microorganisms. As a result, it is a preferred solution for endoscopes, multi-lumen devices, and precision surgical tools.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608