Request A Quote
Low Temperature Circulating Chiller LLTC-G12

Low Temperature Circulating Chiller LLTC-G12

Low Temperature Circulating Chiller LLTC-G12 offers a high-capacity circulation pump with 50L/min 2 bar. It features a plate heat exchanger for effective thermal transfer. Its feedback sensors monitor both inlet and outlet temperatures in real-time. The system includes built-in safety protections against pressure and overload. Our chiller is useful in pilot-scale production setups, where tight thermal control is essential during process scale-up, ensuring reliable performance.

Request Quote
Temperature Range 5°C to 90°C
Temperature Control PLC controller, control the water tank outlet temperature
Temperature Control Accuracy ±0.3°C
Circulation Pump Max 50L/min 2 bar
Refrigerant R-134A/R407C
Heating Power 7.5 kW
Cooling Capacity at 10°C 12 kW
Power AC380V 50HZ / AC460V 50HZ
  • Multi-Voltage Compatibility
  • Steady Process Control
  • Industrial-Grade Performance
  • Advanced Heat Exchanger
  • Temperature Feedback Sensors

Our Low Temperature Circulating Chiller is ideal for pilot-scale production, providing precise thermal control during process scale-up, ensuring reliable performance in both laboratory and industrial chemical and biological applications.

Low Temperature Circulating Chiller LLTC-G12 | Temperature Control Accuracy : ±0.3°C | Circulation Pump Max : 50L/min 2 bar
Low Temperature Circulating Chiller LLTC-G12 | Multi-Voltage Compatibility | Steady Process Control

Models of Low Temperature Circulating Chillers

Labtron Low Temperature Circulating Chillers offer precise temperature control and reliable cooling for laboratory, industrial, and research applications. Their advanced refrigeration systems ensure consistent low-temperature circulation. These chillers feature high-quality components, intuitive controls, and durable construction for efficient thermal management. They operate reliably under varying load conditions, even in continuous or high-demand use. Our chillers are ideal for cooling rotary evaporators, distillation systems, and spectroscopy instruments.

Low Temperature Circulating Chiller LLTC-F15

Low Temperature Circulating Chiller LLTC-F15

  • Temperature Range : -115°C to -80°C
  • Temperature Control : PLC controller, control outlet temperature, 7-inch touch screen
  • Circulation Pump Max : 40L/min 2 bar
  • Refrigerant : Mixed refrigerant 2
Low Temperature Circulating Chiller LLTC-A11

Low Temperature Circulating Chiller LLTC-A11

  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 5m³/h 2 bar
  • Refrigerant : R134A/R407C
Low Temperature Circulating Chiller LLTC-D13

Low Temperature Circulating Chiller LLTC-D13

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 7m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-G10
Low Temperature Circulating Chiller LLTC-G10
  • Temperature Range : 5°C to 90°C
  • Temperature Control : PLC controller, control the water tank outlet temperature
  • Temperature Control Accuracy : ±0.3°C
  • Circulation Pump Max : 20L/min 2 bar
Low Temperature Circulating Chiller LLTC-F11
Low Temperature Circulating Chiller LLTC-F11
  • Temperature Range : -100°C to -65°C
  • Temperature Control : PLC controller, control outlet temperature, 7-inch touch screen
  • Circulation Pump Max : 20L/min 2 bar
  • Refrigerant : Mixed refrigerant 1
Low Temperature Circulating Chiller LLTC-D14

Low Temperature Circulating Chiller LLTC-D14

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 10m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-E14

Low Temperature Circulating Chiller LLTC-E14

  • Temperature Range : -80°C to -50°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 11m³/h 2 bar
  • Refrigerant : R448A/R508B/R23
Low Temperature Circulating Chiller LLTC-E13

Low Temperature Circulating Chiller LLTC-E13

  • Temperature Range : -80°C to -50°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 6.5m³/h 2 bar
  • Refrigerant : R448A/R508B/R23
Low Temperature Circulating Chiller LLTC-G12 FAQ's
  • The chiller offers a high-capacity circulation pump, precise temperature control, real-time temperature feedback, and built-in safety features, making it ideal for various industrial and laboratory applications. It also incorporates a plate heat exchanger for efficient heat transfer. The chiller operates with environmentally friendly refrigerants, optimizing energy consumption. Additionally, its advanced PLC control system allows for seamless integration with automated processes, ensuring reliable and consistent performance in critical applications.

  • The plate heat exchanger enhances thermal efficiency by providing effective heat transfer, helping maintain stable temperatures in complex cooling and heating processes. Its compact design ensures optimal space utilization and easy integration into various systems. The efficient heat exchange minimizes energy consumption while maintaining consistent temperature control. This result in faster process cycles, improved process stability, and reduced operational costs.

  • Yes, the chiller is designed to offer reliable performance in laboratory-scale and pilot-scale industrial applications, providing flexibility for various process sizes. Its adjustable temperature control and high-capacity circulation pump make it suitable for both small-scale research and larger-scale production. The chiller’s robust construction ensures long-term reliability, while its precise thermal control is ideal for processes requiring consistent performance. This versatility allows it to be used across different industries with diverse cooling and heating needs.

  • The circulation pump has a maximum flow rate of 50L/min at 2 bar, ensuring efficient heat transfer and consistent cooling performance. This high flow rate supports quick and reliable cooling across a variety of processes, enhancing the overall performance of the chiller in both industrial and laboratory settings. Its robust flow capacity ensures optimal heat exchange even during demanding operations, improving process stability and reducing thermal variations.

  • By maintaining precise temperature control, the chiller ensures stable conditions for chemical reactions, promoting consistent results and minimizing variability during processes. This stability is crucial for ensuring the reproducibility of results, enhancing the efficiency of reactions, and preventing issues caused by temperature fluctuations. The chiller helps optimize the environment for controlled reactions, which is essential in both small-scale laboratory research and large-scale industrial production.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608