| Evaporating Flask | 1 L |
| Receiving Bottle | 1 L |
| Rotation Speed | 0 to 120 rpm |
| Lifting Distance | 150 mm |
| Temperature Range (Water bath) | RT to 99°C |
| Temperature Range (Oil bath) | RT to 180°C |
| Temperature Control Accuracy | +/- 1°C |
| Vacuum Degree | 0.098 Mpa |
| Control Panel | Digital display of temperature |
| Lifting Motor Power | Manual lift |
| Rotating Motor Power | 40 W |
| Heating Power | 1200 W |
| Capacity | 4.5 L |
| Power Consumption | 1240 W |
| Power Supply | 220 to 240 V,5O Hz |
| Bath Size (L×W) | Φ 220×120 H mm |
| Dimensions (L×W×H) | 640×430×1010 mm |
| Weight | 15 Kg |
Compact bench-top design
PTFE-coated vapour tube
Safety interlock mechanism
Durable stainless steel bath
Corrosion-resistant sealing system
Manual Lifting Rotary Evaporator LMRE-C10 is used for sample drying, solvent recycling, and extract purification. It is extensively used in pharmaceutical, chemical, and research labs for controlled distillation and recovery processes.
Download catalog for
Manual Lifting Rotary Evaporator LMRE-C10 Catalog
Available Range :
Manual Lifting Rotary Evaporator LMRE-C10 : 1 L Manual Lifting Rotary Evaporator LMRE-A10 : 2 L Manual Lifting Rotary Evaporator LMRE-C15 : 3 L Manual Lifting Rotary Evaporator LMRE-C16 : 5 L Manual Lifting Rotary Evaporator LMRE-C18 : Up to 1000ml (compatible with 500 and 1000 ml)Labtron Manual Lifting Rotary Evaporator quickly distill out solvent with wide temperature range of up to 180 °C and 20 to 200 rpm speed range. They offer ergonomic operation with smooth manual lift mechanism. These are easy to operate with integrated interface, vacuum pump, and recirculating chiller. They are expanded with range of accessories and various glass assemblies for flexible evaporation process. Our robust Manual Lifting Rotary Evaporator ensure quick and reliable removal of solvents.








The Manual Lifting Rotary Evaporator LMRE-C10 is equipped with a water bath heating system, which provides uniform heat distribution for consistent solvent evaporation. Its adjustable temperature control enables users to set optimal heating conditions based on the boiling points of different solvents, enhancing operational flexibility. The system maintains stable temperature levels, preventing sudden fluctuations that could impact evaporation efficiency or compromise sample integrity. A built-in safety mechanism prevents overheating, safeguarding both the sample and the equipment from potential damage. The insulated water bath reduces heat loss, improving energy efficiency while maintaining a steady temperature throughout the process. This setup ensures accurate evaporation, reliable solvent recovery, and safe operation in research and industrial laboratories.
Labtron’s Horizontal Rotary Evaporator features an adjustable 0-120 rpm rotation speed, offering flexibility based on solvent properties. At higher speeds, a thin film forms on the flask’s inner surface, increasing surface area for faster solvent removal. Lower speeds are ideal for heat-sensitive compounds, preventing thermal degradation and preserving sample integrity. The rotation mechanism reduces bumping and splashing, minimizing sample loss and ensuring uniform evaporation. By optimizing the speed, users can enhance efficiency across different solvents and laboratory applications. A well-regulated rotation speed also contributes to consistent concentration and purification, improving overall processing reliability.
The Manual Lifting Rotary Evaporator LMRE-C10 is equipped with a PTFE + fluoro rubber double-seal system, ensuring a reliable vacuum seal. This sealing mechanism prevents vapour leaks, maintaining high solvent recovery efficiency. Its chemical-resistant properties allow compatibility with aggressive solvents without compromising performance. A stable vacuum environment reduces contamination risks, ensuring sample purity during evaporation. This durable sealing system enhances operational reliability and extends the lifespan of the rotary evaporator. The advanced sealing design also minimizes maintenance needs, reducing downtime and enhancing long-term efficiency. Its tight seal supports consistent vacuum levels, improving evaporation rates and overall process reliability.
Labtron’s Manual Lifting Rotary Evaporator is designed for high-efficiency solvent recovery, minimizing waste, and maximizing output. Its vacuum system lowers solvent boiling points, allowing evaporation at reduced temperatures while preserving sensitive compounds. A high-performance condenser rapidly cools vapours, converting them into liquid form for collection. The airtight construction prevents vapour loss, ensuring an optimal solvent recovery rate. This system supports efficient distillation, reducing solvent consumption and improving laboratory productivity. Its durable components enhance long-term reliability, making it a valuable tool for chemical synthesis, pharmaceutical extractions, and research applications requiring high-purity solvent recovery.
Our Labtron Rotary Evaporator is equipped with a double-coil condenser, improving solvent vapour cooling efficiency. As vapours pass through, they rapidly condense into liquid, which is collected in the receiving flask. Its large surface area maximizes heat dissipation, accelerating the condensation process. The corrosion-resistant material ensures durability, making it suitable for various laboratory solvents. By enhancing condensation efficiency, this component improves solvent recovery, making the evaporator highly reliable. The efficient design minimizes solvent loss, supporting consistent performance in distillation, purification, and extraction applications.
. Labtron’s Rotary Evaporator features a smooth manual lifting system, allowing precise height adjustments for the evaporation flask. This mechanism provides better control over immersion depth, optimizing heat transfer for efficient solvent evaporation. The user-friendly design ensures quick flask removal and replacement without disrupting the process. It enhances safety by preventing sudden movements that could lead to spills or glass breakage. This system makes the rotary evaporator easy to operate, improving workflow in laboratory settings. Its sturdy construction ensures long-term reliability, making it suitable for continuous use in research and industrial applications.