Manual Lifting Rotary Evaporator LMRE-C12

Manual Lifting Rotary Evaporator LMRE-C12

Manual Lifting Rotary Evaporator LMRE-C12 with a 1 L evaporation flask ensures efficient solvent removal. Its vacuum system boosts evaporation, while stable temperature control protects delicate samples. The large heating vessel ensures even heat distribution, improving consistency and reducing loss. Our Manual Lifting Rotary Evaporator efficiently separates and recovers solvents through controlled evaporation, ensuring consistent laboratory performance.

Manual Lifting Rotary Evaporator LMRE-C12
Manual Lifting Rotary Evaporator LMRE-C12
Manual Lifting Rotary Evaporator LMRE-C12
Manual Lifting Rotary Evaporator LMRE-C12 Video
Request Quote
Evaporating Flask 1 L
Receiving Bottle 1 L
Rotation Speed 0 to 120 rpm
Lifting Distance 200 mm
Lifting Mode Manual
Temperature Range RT to 180°C
Temperature Control Accuracy +/- 1°C
Vacuum Degree 0.098 Mpa
Condensing Area 0.17 m2
Rotating Motor Power 40 W
Heating Power 1200 W
Bath Capacity 6.6 L
Power Consumption 1240 W
Power Supply 220 to 240 V,5O Hz
Dimensions (L×W×H) 700×300×1060 mm
Weight 17 Kg
  • Adjustable rotation speed

  • Efficient condensation area

  • Chemical-resistant sealing system

  • Durable borosilicate glassware

  • Corrosion-resistant bath chamber

Manual Lifting Rotary Evaporator LMRE-C12 is used for solvent recovery, concentration, and sample drying in research, pharmaceutical, and industrial labs. It also supports extraction, purification, and sample preparation for analytical techniques like HPLC and GC.



Models of Manual Lifting Rotary Evaporator

Labtron Manual Lifting Rotary Evaporator quickly distill out solvent with wide temperature range of up to 180 °C and 20 to 200 rpm speed range. They offer ergonomic operation with smooth manual lift mechanism. These are easy to operate with integrated interface, vacuum pump, and recirculating chiller. They are expanded with range of accessories and various glass assemblies for flexible evaporation process. Our robust Manual Lifting Rotary Evaporator ensure quick and reliable removal of solvents.

Manual Lifting Rotary Evaporator LMRE-C11

Manual Lifting Rotary Evaporator LMRE-C11

  • Evaporating Flask : 1 L
  • Receiving Bottle : 1 L
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 150 mm
Manual Lifting Rotary Evaporator LMRE-C16

Manual Lifting Rotary Evaporator LMRE-C16

  • Evaporating Flask : 5 L
  • Receiving Bottle : 3 L (with discharge valve)
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 200 mm
Manual Lifting Rotary Evaporator LMRE-C18

Manual Lifting Rotary Evaporator LMRE-C18

  • Evaporating Flask : Up to 1000ml (compatible with 500 and 1000 ml)
  • Receiving Bottle : 1000 ml
  • Rotation Speed : 20 to 180 rpm
  • Rotation Control : Electric
Manual Lifting Rotary Evaporator LMRE-A10
Manual Lifting Rotary Evaporator LMRE-A10
  • Evaporating Flask : 2 L
  • Lifting Mode : Manual
  • Optional Evaporating Flask : 0.25 L, 1L
  • Condenser Type : Vertical condenser and top cold trap
Manual Lifting Rotary Evaporator LMRE-C15
Manual Lifting Rotary Evaporator LMRE-C15
  • Evaporating Flask : 3 L
  • Receiving Bottle : 2 L
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 200 mm
Manual Lifting Rotary Evaporator LMRE-C17

Manual Lifting Rotary Evaporator LMRE-C17

  • Evaporating Flask : 5 L
  • Receiving Bottle : 3 L (with discharge valve)
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 200 mm
Manual Lifting Rotary Evaporator LMRE-A20

Manual Lifting Rotary Evaporator LMRE-A20

  • Speed Range : 20 to 200 rpm
  • Motor Type : Brushless DC motor
  • Clockwise and Anti-clockwise : Yes
  • Control Accuracy Water : ±1°C
Manual Lifting Rotary Evaporator LMRE-B10

Manual Lifting Rotary Evaporator LMRE-B10

  • Rotary Evaporating Flask : 3 L
  • Optional Evaporating Flask : 1 L, 2 L
  • Receiving Flask : 2 L
  • Rotating Speed Range : 0 to 120 rpm
Manual Lifting Rotary Evaporator LMRE-C12 FAQ's
  • Our Manual Lifting Rotary Evaporator ensures reliable and safe use in busy laboratory settings. It features thermal protection that prevents the unit from overheating, even during extended operations. The glassware is made from borosilicate, offering high resistance to cracking and chemical stress. Its manual lifting mechanism reduces reliance on electronic components, lowering the chances of malfunction. The compact design takes up minimal space, making it suitable for shared benches. Quiet operation ensures it does not disturb surrounding work. Electrical parts are well protected, adding to the overall safety profile of the system. This design is ideal for teaching labs or multi-user environments where stability and ease of use are vital. It also reduces the risk of accidents during frequent adjustments or handling.

  • The Labtron’s Manual Lifting Rotary Evaporator is a dependable tool for effective solvent recovery in laboratory processes. It includes vacuum support, which enables evaporation at lower temperatures, reducing the risk of solvent loss. The recovered solvents remain uncontaminated and ready for repeated use. It is particularly suitable for laboratories that focus on reducing chemical waste. Its condenser provides ample surface area for vapour condensation. Controlled heating allows the evaporation of various solvents with different boiling points. The LMRE-C12 model is commonly used for consistent solvent recovery in daily lab operations. This helps reduce operating costs while maintaining reproducibility in experiments. The setup supports long-term sustainability goals within lab workflows.

  • Manual Lifting Rotary Evaporator LMRE-C12 is designed to improve workflow in demanding lab environments. It features adjustable rotation speeds, allowing users to match conditions to the solvent or sample. The manual lifting mechanism enables quick transitions between processes. Consistent temperature control ensures reproducible results, even with sensitive compounds. A vertical condenser provides fast vapour condensation, reducing experiment time. The space-saving design allows integration with other equipment on the same bench. It’s a practical choice for laboratories needing high output with minimal downtime. LMRE-C12 also simplifies handling, helping new lab users operate confidently with minimal instruction. Its mechanical simplicity translates to less maintenance and more experiment time.

  • Manual Lifting Rotary Evaporator LMRE-C12 is well suited for handling heat-sensitive compounds. It allows evaporation under vacuum, lowering boiling points and reducing heat exposure. This ensures compounds like esters or essential oils remain stable during processing. A gentle, uniform heat from the bath prevents overheating of localised areas. Consistent temperature regulation keeps fluctuations within tight limits. The rotary motion enhances sample distribution, avoiding thermal concentration. This makes it a valuable tool in labs working with delicate organic or volatile substances. Researchers in natural product chemistry benefit greatly from its thermal control. It also supports accurate sample recovery for downstream analysis or formulation.

  • Yes, the Manual Lifting Rotary Evaporator performs efficiently with small sample sizes. Its flask capacity is suited to low-volume extractions, reducing waste and increasing yield. Vacuum evaporation maximises recovery, even from minimal amounts of solvent. Rotary action promotes even exposure to heat without excessive sample dispersion. The heating bath responds quickly to changes, saving time. It supports precise applications often needed in analytical or testing labs. It provides consistent results even when working with tiny quantities. This makes it ideal for R&D environments, quality control units, and pilot testing. The system is optimised to handle delicate workflows without compromising performance.

  • Manual Lifting Rotary Evaporator is built for user-friendly cleaning and upkeep. All glass components can be disassembled easily and rinsed without special tools. The PTFE seals resist chemical accumulation, reducing the need for deep cleaning. Electrical parts are shielded, preventing contamination during maintenance. Smooth glass and metal surfaces make it easier to wipe off residues. It does not require professional servicing for regular cleaning tasks. Clear assembly design means users can quickly prepare the unit for the next experiment. This helps reduce equipment downtime and supports back-to-back usage. The cleaning process also supports strict lab hygiene standards where cross-contamination must be avoided.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608