Request A Quote
Manual Lifting Rotary Evaporator LMRE-C11

Manual Lifting Rotary Evaporator LMRE-C11

Manual Lifting Rotary Evaporator LMRE-C11 features a 1 L evaporation flask capacity for effective solvent evaporation. Its PTFE fluoro rubber double-seal system prevents vapour leaks, ensuring stable vacuum conditions. The high-efficiency heating system ensures uniform temperature distribution, regulating evaporation and reducing thermal degradation. Our Manual Lifting Rotary Evaporator supports drying and solvent recovery in laboratories.

Manual Lifting Rotary Evaporator LMRE-C11
Manual Lifting Rotary Evaporator LMRE-C11
Manual Lifting Rotary Evaporator LMRE-C11
Manual Lifting Rotary Evaporator LMRE-C11 Video
Request Quote
Evaporating Flask 1 L
Receiving Bottle 1 L
Rotation Speed 0 to 120 rpm
Lifting Distance 150 mm
Temperature Range (Water bath) RT to 99°C
Temperature Range (Oil bath) RT to 180°C
Temperature Control Accuracy +/- 1°C
Capacity 6.5 L
Vacuum Degree 0.098 Mpa
Control Panel Digital display of temperature
Lifting Motor Power 15 W
Rotating Motor Power 40 W
Heating Power 1200 W
Power Consumption 1255 W
Power Supply 220 to 240 V,5O Hz
Bath Size (L×W) Φ 245×140 H mm
Dimensions (L×W×H) 650×440×1030 H mm
Weight 16 Kg
  • Space-saving vertical design

  • Chemically resistant glass components

  • Rapid cooling double-coil condenser

  • Secure flask locking mechanism

  • Adjustable rotation speed control

Manual Lifting Rotary Evaporator LMRE-C11 is essential for chemical, pharmaceutical, and research laboratories, enabling effective solvent recovery. It supports sample drying and controlled distillation, maintaining purity and consistency in extraction processes.



Models of Manual Lifting Rotary Evaporator

Labtron Manual Lifting Rotary Evaporator quickly distill out solvent with wide temperature range of up to 180 °C and 20 to 200 rpm speed range. They offer ergonomic operation with smooth manual lift mechanism. These are easy to operate with integrated interface, vacuum pump, and recirculating chiller. They are expanded with range of accessories and various glass assemblies for flexible evaporation process. Our robust Manual Lifting Rotary Evaporator ensure quick and reliable removal of solvents.

Manual Lifting Rotary Evaporator LMRE-C16

Manual Lifting Rotary Evaporator LMRE-C16

  • Evaporating Flask : 5 L
  • Receiving Bottle : 3 L (with discharge valve)
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 200 mm
Manual Lifting Rotary Evaporator LMRE-C13

Manual Lifting Rotary Evaporator LMRE-C13

  • Evaporating Flask : 1 L
  • Receiving Bottle : 1 L
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 200 mm
Manual Lifting Rotary Evaporator LMRE-C14

Manual Lifting Rotary Evaporator LMRE-C14

  • Evaporating Flask : 3 L
  • Receiving Bottle : 2 L
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 200 mm
Manual Lifting Rotary Evaporator LMRE-C18
Manual Lifting Rotary Evaporator LMRE-C18
  • Evaporating Flask : Up to 1000ml (compatible with 500 and 1000 ml)
  • Receiving Bottle : 1000 ml
  • Rotation Speed : 20 to 180 rpm
  • Rotation Control : Electric
Manual Lifting Rotary Evaporator LMRE-C10
Manual Lifting Rotary Evaporator LMRE-C10
  • Evaporating Flask : 1 L
  • Receiving Bottle : 1 L
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 150 mm
Manual Lifting Rotary Evaporator LMRE-C12

Manual Lifting Rotary Evaporator LMRE-C12

  • Evaporating Flask : 1 L
  • Receiving Bottle : 1 L
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 200 mm
Manual Lifting Rotary Evaporator LMRE-C17

Manual Lifting Rotary Evaporator LMRE-C17

  • Evaporating Flask : 5 L
  • Receiving Bottle : 3 L (with discharge valve)
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 200 mm
Manual Lifting Rotary Evaporator LMRE-C15

Manual Lifting Rotary Evaporator LMRE-C15

  • Evaporating Flask : 3 L
  • Receiving Bottle : 2 L
  • Rotation Speed : 0 to 120 rpm
  • Lifting Distance : 200 mm
Manual Lifting Rotary Evaporator LMRE-C11 FAQ's
  • Our Manual Lifting Rotary Evaporator is designed for essential oil extraction while preserving delicate aromatic compounds. The vacuum system lowers boiling points, reducing heat exposure that could degrade essential oils. A high-efficiency condenser rapidly cools vapours, ensuring complete recovery without loss. The digital temperature control provides controlled heat application, optimizing the separation process. A sealed system prevents contamination, maintaining the purity of extracted oils in botanical applications. The unit’s robust construction supports extended operation, making it ideal for laboratories conducting botanical extractions. Its versatility allows for precise adjustments, ensuring efficiency across various types of plant-based extractions.

  • The Manual Lifting Rotary Evaporator features an integrated condenser that efficiently cools vapours, reducing the need for an external cooling system. However, an external chiller can enhance performance, especially for low-boiling-point solvents requiring rapid condensation. The double-coil condenser ensures effective heat dissipation, maintaining a stable evaporation process. Proper cooling minimizes solvent loss and improves efficiency in large-scale applications. The corrosion-resistant condenser ensures compatibility with a wide range of solvents, allowing long-term reliability. For laboratories handling multiple solvent types, a supplementary cooling system can further improve recovery rates and process consistency.

  • Labtron’s Manual Lifting Rotary Evaporator adapts to altitude variations by allowing precise vacuum and temperature control. At higher elevations, reduced atmospheric pressure lowers solvent boiling points, increasing evaporation rates. The vacuum system compensates for these changes, ensuring stable conditions for controlled solvent removal. Proper regulation prevents bumping or foaming, which can occur due to pressure fluctuations. The system maintains consistent performance across different environments by allowing fine adjustments in temperature and pressure. Laboratories operating in high-altitude locations can rely on its adaptability to ensure reproducible results without compromising solvent recovery efficiency.

  • Our LMRE-C11 Manual Lifting Rotary Evaporator is designed to dry heat-sensitive samples while preventing degradation and structural damage. The vacuum function lowers boiling points, enabling solvent removal at reduced temperatures to protect delicate compounds. The controlled rotation ensures even heat distribution, avoiding localised overheating and uneven drying. A digital display provides real-time monitoring for precise adjustments during the drying process. The high-efficiency condenser ensures complete solvent recovery, maintaining sample integrity in pharmaceutical and food research. Its ability to maintain uniform temperature and vacuum conditions makes it an essential tool for research facilities handling fragile biological or chemical samples.

  • Our LMRE-C11 Manual Lifting Rotary Evaporator is designed to dry heat-sensitive samples while preventing degradation and structural damage. The vacuum function lowers boiling points, enabling solvent removal at reduced temperatures to protect delicate compounds. The controlled rotation ensures even heat distribution, avoiding localised overheating and uneven drying. A digital display provides real-time monitoring for precise adjustments during the drying process. The high-efficiency condenser ensures complete solvent recovery, maintaining sample integrity in pharmaceutical and food research. Its ability to maintain uniform temperature and vacuum conditions makes it an essential tool for research facilities handling fragile biological or chemical samples.

  • Our LMRE-C11 Manual Lifting Rotary Evaporator is designed with multiple features to minimise foaming and bumping for smooth solvent evaporation. The adjustable vacuum control gradually reduces pressure, preventing sudden fluctuations that cause excessive bubbling. The variable rotation speed ensures uniform film formation, reducing turbulence and minimizing the risk of splashing. A well-sized evaporation flask helps maintain a controlled boiling process, preventing overflow. Anti-foam agents can be used for highly volatile solvents to further stabilize evaporation. The optimized temperature and vacuum control system ensures uniform solvent removal, improving process efficiency. With its manual lifting mechanism, users can quickly adjust flask positioning, further reducing the risk of overflow and ensuring a controlled distillation process.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.